| Model |
PS2010 PS2020 Spectrocolorimeter |
PS2030 PS2040 Spectrocolorimeter |
PS2050 PS2060 Spectrocolorimeter |
PS2070 PS2080 Spectrocolorimeter |
| Optical Geometry |
D/8(diffused illumination, 8-degree viewing angle), SCI/SCE (specular component included/specular component excluded) Mode, Comply toCIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
| Characteristic |
Adopt CMOS dual beam splitting sensor;Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries. |
Adopt CMOS dual beam splitting sensor;Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, also for fluorescence sample measurement. |
| Light Source |
Combined full spectrum LED light source |
Combined full spectrum LED light source, UV light source |
| Integrating Sphere Size |
Φ40mm |
| Sensor |
CMOS dual beam splitting sensor |
| Wavelength Range |
400-700nm |
| Measuring Aperture |
PS2010 Single aperture:Φ8mm flat |
PS2030 Two Apertures:MAV:Φ8mm/Φ10mm |
PS2050 Two Apertures:MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm |
PS2070 Four Apertures:MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm |
| PS2020 Single aperture:Φ4mm flat |
PS2040 Two Apertures:SAV:Φ4mm/Φ5mm |
PS2060 Three Apertures:MAV:Φ8mm;SAV:Φ4mm;LAV:1x3mm |
PS2080 Six Apertures:MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm |
| Specular Component |
SCI/SCE |
| Color Space |
CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB, HunterLab, βxy, DIN Lab99 |
| Color Difference Formula |
ΔE*ab,ΔE*uv, ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1), ΔE*00, DINΔE99,ΔE(Hunter) |
| Other Colorimetric Index |
Spectral reflectance, WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313),Metamerism Index Mt,Staining Fastness, Color Fastness,Color Strength, Opacity,555 tone classification, Munsell(C/2)(Partially realize through the PC software /APP software) |
| Observer Angle |
2°/10° |
| Illuminant |
D65, A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),U35,NBF,ID50,ID65(Partially realize through the PC software /APP software) |
| Display |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
| Measuring Time |
About 1s |
| Repeatability |
Chromaticity value: MAV/SCI, within ΔE*ab 0.04 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.035 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.03 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.02 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
| Inter-instrument Error |
MAV/SCI, Within ΔE*ab 0.4 (Average for 12 BCRA Series II color tiles) |
MAV/SCI, Within ΔE*ab 0.35 (Average for 12 BCRA Series II color tiles) |
MAV/SCI, Within ΔE*ab 0.3 (Average for 12 BCRA Series II color tiles) |
MAV/SCI, Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) |
| Displayed Accuracy |
0.01 |
| Measured Reflectance Range |
0-200% |
| Reflectance Resolution |
0.01% |
| Measurement Mode |
Single Measurement, Average Measurement(2-99times) |
| Locating Method |
Stabilizer position |
Stabilizer position+camera locating |
| White Calibration mode |
Contact type automatic calibration |
Non-contact automatic calibration |
| Dimension |
94X68X188mm |
| Weight |
About 270g |
| Battery |
Lithium battery,3.7V,5000mAh,8000 cycles in 8 hours |
| Illuminant Life Span |
More than 1.2 million measurements over 10 years |
| Screen |
2.8 inch TFT true color, Capacitive Touch Screen |
| Interface |
USB |
USB,Bluetooth® 5.0 |
| Data Storage |
Standard 500 Pcs, Sample 5000 Pcs(One data is able to include SCI/SCE);PC mass storage |
Standard 500 Pcs, Sample 10,000 Pcs (One data is able to include SCI/SCE); PC mass storage |
| Software support |
Windows |
Android, IOS, Windows, Wechat small program, Hongmeng |
| Language |
Simplified Chinese, English, Traditional Chinese |
| Operating Environment |
0~40℃, 0~85%RH (no condensing),Altitude < 2000m |
| Storage Environment |
-20~50℃, 0~85%RH (no condensing) |
| Standard Accessory |
Power Adapter, USB Cable, User Guide, SQCX PC Software (Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, Aperture |
| Optional Accessory |
USB Micro Printer, Powder Test Box |
| Notes |
Technical parameters are only for reference, subject to the actual sale of the product
|