Model |
NS800 |
NS810 |
NS820 |
Illumination/Observation System |
45/0 method (45 ring-shaped illumination, vertical viewing), Conforms to CIE No.15,GB/T 3978 |
d/8 (diffused illumination, 8degree viewing angle) Conforms to CIE No.15, GB/T 3978. |
d/8 (diffused illumination, 8-degree viewing angle) Conforms to CIE No.15, GB/T 3978. |
Integrating Sphere Size |
Φ58mm |
Φ58mm |
Φ58mm |
Light Source |
Combined LED sources |
Combined LED sources |
Combined LED sources |
Sensor |
Silicon photodiode array |
Silicon photodiode array |
Silicon photodiode array |
Wavelength Range |
400~700nm |
400~700nm |
400~700nm |
Wavelength Interval |
10nm |
10nm |
10nm |
Reflectance Range |
0~200% |
0~200% |
0~200% |
Measuring Aperture |
Φ8mm |
Φ8mm |
Φ4mm |
Color Space |
CIE LAB,XYZ,Yxy,LCh,CIE LUV |
CIE LAB, XYZ, Yxy, LCh, CIE LUV,LAB&WI&YI |
CIE LAB, XYZ, Yxy, LCh, CIE LUV,LAB&WI&YI |
Color Difference Formula |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*cmc(l:c),CIE2000ΔE*00,ΔE(h) |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*cmc(l:c),CIE2000ΔE*00,ΔE(h) |
Other Chromaticity Data |
WI(ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925,ASTM 313), Metamerism Index (Mt), Color Stain, Color Fastness |
WI(ASTM E313,CIE/ISO,AATCC, Hunter), YI (ASTM D1925,ASTM 313),TI(ASTM E313,CIE/ISO), Metamerism Index (Mt), Strength, Color Stain, Color Fastness |
Whiteness - WI (ASTM E313,CIE/ISO,AATCC,Hunter),Yellowness-YI (ASTM D1925,ASTM 313), TI (ASTM E313,CIE/ISO), Metamerism Index (Mt) Colour Stain, Color Fastness, Color Strength, Opacity |
Observer |
2°/10° |
2°/10° |
2°/10° |
Illuminant |
D65, A, C, D50,D55,D75,F2,F6,F7,F8,F10,F11, F12 |
D65,A, C, D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10 (TPL5)F11 (TL84), F12 (TL83/U30) |
D65,D50,A,C,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Display Data |
Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation |
Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation, color index setting(ΔE*94, ΔE*cmc, ΔE2000), tolerance prompt, reverse prompt, time setting, language setting, restore factory setting |
Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation, color index setting(ΔE*94, ΔE*cmc, ΔE2000), tolerance prompt, reverse prompt, time setting, language setting, restore factory setting |
Measurement Time |
1.5s |
1.2s |
1.5s |
Repeatability |
Spectral Reflectance: standard deviation within 0.1%(400~700nm: within 0.2%) |
Spectral Reflectance: standard deviation within 0.1%(400~700nm: within 0.2%) |
Spectral Reflectance: standard deviation within 0.1%(400~700nm: within 0.2%) |
Colorimetric Value |
Standard deviation within Delta E*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) |
Colorimetric Value: Standard deviation within DeltaE*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) |
Colorimetric Value: Standard deviation within DeltaE*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) |
Inter Instrument Agreement |
Within Delta E*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Within DeltaE*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Within Delta E*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Dimension |
L*W*H=90*77*230mm |
L*W*H=90*77*230mm |
L*W*H=90*77*230mm |
Weight |
600g |
600g |
600g |
Battery |
Li-ion battery. 5000 times within 8 hours |
Li-ion battery. 2800 times within 8 hours. |
Li-ion battery. 2800 times within 8 hours. |
Lamp Life |
5 years, more than 1.6 million measurements |
5 years, more than 1.6 million measurements |
5 years, more than 1.6 million measurements |
Display Screen |
TFT 3.5inch, Capacitive Touch Screen |
TFT 3.5inch, Capacitive Touch Screen |
TFT 3.5inch, Capacitive Touch Screen |
Interface |
USB/RS-232 |
USB/RS-232 |
USB/RS-232 |
Data Memory |
1000 Standards, 15000 Samples |
1000 Standards, 15000 Samples |
1000 Standards, 15000 Samples |
Operating Temperature |
0~40℃(32~104°F) |
0~40℃(32~104°F) |
0~40℃(32~104°F) |
Storage temperature |
-20~50℃(-4~122°F) |
-20~50℃(-4~122°F) |
-20~50℃(-4~122°F) |
Standard Accessory |
ower Adapter, Li-ion Battery, Operating Instruction, CD-ROM (containing management software), Data Line, White and Black Calibration Cavity, Protective Cover and Wrist Strap |
Power Adapter, Li-ion Battery, Operating Instruction, CD-ROM (containing management software), Data Line, White and Black Calibration Cavity, Protective Cover and Wrist Strap |
Power Adapter, Li-ion Battery, Operating Instruction, SQC8 software, White and Black Calibration Cavity, Protective Cover and Wrist Strap |
Optional Accessories |
Micro Printer, Universal Test Component |
Micro Printer, Powder Test Box |
Universal Test Components, Micro Printer, Powder Test Box |
Other |
Provide complete spectrum reflectance curve, Input L, a, b value manually |
|
|
Notes |
The specifications are subject to change without notice |
The specifications are subject to change without notice. |
The specifications are subject to change without notice. |