Model |
YL4560 |
Optical Geometry |
45/0 method (45 ring-shaped illumination, vertical viewing); Conforms to CIE No.15,GB/T 3978,GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7, GB 2893,GB/T 18833 |
Features |
45/0 non-contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, paint and ink, printing, ceramics and other industries, and also for fluorescence sample measurement. |
Light Source |
Full spectrum LED light,UV light |
Spectrophotometric Mode |
Concave Grating |
Sensor |
256 Image Element Double Array CMOS Image Sensor |
Wavelength Range |
400~700nm/10nm output |
Reflectance Range |
0~200% |
Measuring Aperture |
Φ20mm(can be customized <20mm) |
Non-contact Distance |
7.5mm |
Sample Height |
0~150mm |
Distance Adjustment Method |
Manual adjustment and automatic adjustment (test height can be stored) |
Measuring mode |
Sample mode/QC Mode/Continuous statistics mode |
Locating Method |
Camera Locating |
Color Space |
CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
Color Difference Formula |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) |
Other Colorimetric Index |
WI (ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),TI(ASTM E313,CIE/ISO), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity |
Observer Angle |
2°/10° |
Illuminant |
D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30) |
Displayed Data |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, Chromaticity Graph, Color Simulation, PASS/FAIL Result, Color Offset |
Measuring Time |
About 1.5s |
Data Storage |
Sample mode + QC mode: 40,000; Continuous statistics mode: 10,000 |
Repeatability |
Spectral reflectance: Standard deviation within 0.08% Chromaticity value: Within ΔE*ab 0.03 (when a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error |
Within ΔE*ab 0.2(Average for 12 BCRA Series II color tiles) |
Measurement Mode |
Single Measurement, Average Measurement(2 ~ 99 times) |
Dimension |
330*250*370mm |
Weight |
About 10 kg |
Power Supply |
DC 24V, 3A Power Adapter |
Illuminant Life Span |
5 years, more than 3 million times measurements |
Display Screen |
7" TFT Capacitive Screen-touch Display |
Data Port |
USB/RS-232,Bluetooth®4.0 |
Language |
Simplified Chinese,Traditional Chinese,English |
Working Environment |
Temperature: 0~40℃; Humidity: 0~85% (No Condensation); Altitude < 2000m |
Storage Environment |
Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory |
Power Adapter, User Manual, USB cable, Standard Calibration Board, Black Calibration Cavity, |
Notes |
The specifications are subject to change without notice.
|