Online Dual-Channel pH/Conductivity Analyzer
Product Notes:
1. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and handling.
2. Custom options and configurations are also available. Please contact us if you need help with your specific application.
Download
Download
Sper Scientific Online pH/Conductivity Analyzer monitors one analog pH or ORP sensor and one analog conductivity sensor simultaneously.
It combines two measurement channels in a compact panel-mounted instrument for continuous water quality monitoring in industrial processes, water treatment and wastewater applications.
The pH/ORP channel supports acidity or oxidation-reduction potential measurement, while the conductivity channel provides conductivity, TDS, salinity or resistivity readings. Temperature measurement and compensation support consistent process evaluation when used with compatible probes. Actual measurement range, process temperature limits and overall system performance depend on the sensors selected.
A 3.1-inch backlit LCD displays process readings, while the front-panel buttons provide access to measurement and output settings. Two configurable 4–20 mA outputs and RS485 Modbus RTU communication support integration with PLCs and plant monitoring systems. Three relay outputs provide alarm and supported control functions.
Historical data records and trend curves help review process changes. Recording intervals can be set from 1–999 minutes, and stored data can be exported to a computer over USB. The ABS enclosure has an IP65 protection rating, with standard 100–240 VAC power and an optional 24 VDC configuration.
Features
- Simultaneous pH/ORP and conductivity monitoring with compatible analog sensors
- Conductivity-channel functions include EC, TDS, salinity and resistivity
- Temperature compensation with multiple supported temperature sensor types
- 3.1-inch backlit LCD and front-panel controls
- Two configurable 4–20 mA outputs
- RS485 Modbus RTU communication for PLC integration
- Three relay outputs for alarm and supported control functions
- Historical data logging and trend curve display
- Adjustable data recording intervals from 1–999 minutes
- USB export of stored records
- IP65-rated ABS enclosure
- Standard AC power with an optional 24 VDC version
Specifications
| Parameter | Specification |
|---|---|
| Model | 870002D |
| Measurement channels | One analog pH/ORP sensor and one analog conductivity sensor, operating simultaneously |
| pH range | −2.00 to 16.00 pH |
| ORP range | −2,000 to +2,000 mV |
| Conductivity range | 0–2,000,000 µS/cm (0–2,000 mS/cm) |
| TDS range | 0–130,000 mg/L (ppm) |
| Resistivity range | 0–20 MΩ·cm |
| Salinity | Supported; usable range depends on sensor and configuration |
| Channel 1 temperature range | −30.0 to 130.0°C |
| Channel 2 temperature range | −40.0 to 200.0°C |
| Accuracy | pH: ±0.01 pH; ORP: ±1 mV; conductivity: ±2%; temperature: ±0.5°C |
| Temperature compensation inputs | NTC30k, NTC22k, NTC10k, Pt1000 and NTC2.252k |
| Display | 3.1-inch backlit digital LCD |
| Analog outputs | Two configurable 4–20 mA outputs |
| Digital interface | RS485, Modbus RTU |
| Relays | Three; contacts rated 5 A at 250 VAC or 5 A at 30 VDC |
| Data logging | Historical records and curves; adjustable recording interval 1–999 minutes |
| Data export | USB connection to computer |
| Standard power | 100–240 VAC, 50/60 Hz |
| Optional power | 24 VDC |
| Power consumption | 4 W |
| Housing / protection | ABS plastic / IP65 |
| Dimensions / weight | 144 × 144 × 104 mm / 0.9 kg |
| Operating environment | −20 to 50°C; ≤95% RH, non-condensing |
| Storage environment | −40 to 70°C; ≤95% RH, non-condensing |
| Altitude / overvoltage category / pollution degree | ≤2,000 m / II / 2 |
| Languages | English, Simplified Chinese, Traditional Chinese and Russian |
| Country of origin | China |
Listed measurement limits are controller capabilities. Select compatible electrodes with ranges, temperature ratings and process connections appropriate for the application.
Downloads
FAQs
Can the DCA130 measure pH and conductivity at the same time?
Yes. It supports one pH/ORP sensor and one conductivity sensor simultaneously.
Can it measure pH and ORP simultaneously?
The first channel uses a pH or ORP sensor. The second channel is intended for conductivity measurements.
What measurements are available on the conductivity channel?
Conductivity, TDS, salinity and resistivity functions are supported. Available ranges depend on the electrode and configuration.
Can it connect to a PLC?
Yes. The analyzer provides RS485 Modbus RTU and two configurable 4–20 mA outputs.
Can historical readings be exported?
Yes. Stored data can be exported to a computer over USB. Logging pauses while the USB connection is active and resumes after disconnection.
Are sensors included?
Sensor inclusion has not been specified. Select the required pH/ORP and conductivity probes for your installation and confirm the package before ordering.
Couldn't load pickup availability
Product Information
Product Information
Sper Scientific Online pH/Conductivity Analyzer monitors one analog pH or ORP sensor and one analog conductivity sensor simultaneously.
It combines two measurement channels in a compact panel-mounted instrument for continuous water quality monitoring in industrial processes, water treatment and wastewater applications.
The pH/ORP channel supports acidity or oxidation-reduction potential measurement, while the conductivity channel provides conductivity, TDS, salinity or resistivity readings. Temperature measurement and compensation support consistent process evaluation when used with compatible probes. Actual measurement range, process temperature limits and overall system performance depend on the sensors selected.
A 3.1-inch backlit LCD displays process readings, while the front-panel buttons provide access to measurement and output settings. Two configurable 4–20 mA outputs and RS485 Modbus RTU communication support integration with PLCs and plant monitoring systems. Three relay outputs provide alarm and supported control functions.
Historical data records and trend curves help review process changes. Recording intervals can be set from 1–999 minutes, and stored data can be exported to a computer over USB. The ABS enclosure has an IP65 protection rating, with standard 100–240 VAC power and an optional 24 VDC configuration.
Features
- Simultaneous pH/ORP and conductivity monitoring with compatible analog sensors
- Conductivity-channel functions include EC, TDS, salinity and resistivity
- Temperature compensation with multiple supported temperature sensor types
- 3.1-inch backlit LCD and front-panel controls
- Two configurable 4–20 mA outputs
- RS485 Modbus RTU communication for PLC integration
- Three relay outputs for alarm and supported control functions
- Historical data logging and trend curve display
- Adjustable data recording intervals from 1–999 minutes
- USB export of stored records
- IP65-rated ABS enclosure
- Standard AC power with an optional 24 VDC version
Specifications
| Parameter | Specification |
|---|---|
| Model | 870002D |
| Measurement channels | One analog pH/ORP sensor and one analog conductivity sensor, operating simultaneously |
| pH range | −2.00 to 16.00 pH |
| ORP range | −2,000 to +2,000 mV |
| Conductivity range | 0–2,000,000 µS/cm (0–2,000 mS/cm) |
| TDS range | 0–130,000 mg/L (ppm) |
| Resistivity range | 0–20 MΩ·cm |
| Salinity | Supported; usable range depends on sensor and configuration |
| Channel 1 temperature range | −30.0 to 130.0°C |
| Channel 2 temperature range | −40.0 to 200.0°C |
| Accuracy | pH: ±0.01 pH; ORP: ±1 mV; conductivity: ±2%; temperature: ±0.5°C |
| Temperature compensation inputs | NTC30k, NTC22k, NTC10k, Pt1000 and NTC2.252k |
| Display | 3.1-inch backlit digital LCD |
| Analog outputs | Two configurable 4–20 mA outputs |
| Digital interface | RS485, Modbus RTU |
| Relays | Three; contacts rated 5 A at 250 VAC or 5 A at 30 VDC |
| Data logging | Historical records and curves; adjustable recording interval 1–999 minutes |
| Data export | USB connection to computer |
| Standard power | 100–240 VAC, 50/60 Hz |
| Optional power | 24 VDC |
| Power consumption | 4 W |
| Housing / protection | ABS plastic / IP65 |
| Dimensions / weight | 144 × 144 × 104 mm / 0.9 kg |
| Operating environment | −20 to 50°C; ≤95% RH, non-condensing |
| Storage environment | −40 to 70°C; ≤95% RH, non-condensing |
| Altitude / overvoltage category / pollution degree | ≤2,000 m / II / 2 |
| Languages | English, Simplified Chinese, Traditional Chinese and Russian |
| Country of origin | China |
Listed measurement limits are controller capabilities. Select compatible electrodes with ranges, temperature ratings and process connections appropriate for the application.
Downloads
FAQs
Can the DCA130 measure pH and conductivity at the same time?
Yes. It supports one pH/ORP sensor and one conductivity sensor simultaneously.
Can it measure pH and ORP simultaneously?
The first channel uses a pH or ORP sensor. The second channel is intended for conductivity measurements.
What measurements are available on the conductivity channel?
Conductivity, TDS, salinity and resistivity functions are supported. Available ranges depend on the electrode and configuration.
Can it connect to a PLC?
Yes. The analyzer provides RS485 Modbus RTU and two configurable 4–20 mA outputs.
Can historical readings be exported?
Yes. Stored data can be exported to a computer over USB. Logging pauses while the USB connection is active and resumes after disconnection.
Are sensors included?
Sensor inclusion has not been specified. Select the required pH/ORP and conductivity probes for your installation and confirm the package before ordering.
Description
Description
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Category: Laboratory Equipment
A few of our valued customers:

