| Model |
MS3003 |
| Measurement Geometry |
3 measurement angles (3 illumination sources, 1 receivers) |
| Measure Angle |
45° Receiver: 45as25°,45as45°,45as110° Conform to the standards: ASTM D 2244,E 308,E 1164,E 2194, E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4 SAE J 1545 |
| Application |
Provide accurate and consistent color measurement for metallic, pearlescent and other complex special effect color products |
| Light Source |
Full spectrum LED light source with blue enhancement |
| Lamp Life |
5 years, 3 million times measurements |
| Spectrophotometric Mode |
Concave Grating |
| Sensor |
256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range |
400nm-700nm |
| Wavelength Interval |
10nm |
| Measurement Range |
0~600% |
| Semiband Width |
10nm |
| Measuring Aperture |
Illumination size Φ23mm / Measuring spot 9X12mm |
| Color Space |
CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99 |
| Color Difference Formula |
ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE DIN6175 |
| Other Colorimetric Index |
Flop Index |
| Observer Angle |
2°/10° |
| Illuminant |
D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
| Display |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time |
Approx. 1 second for one angle Approx. 3 seconds for all angles |
| Repeatability |
Spectral reflectance: Standard deviation within 0.08% Chromaticity value: ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Reproducibility |
ΔE*<0.10,avg on the gray tile of BCRA tile set ΔE*<0.25,avg on the color BCRA tile set |
| Inter-instrument Error |
0.2ΔE*00(avg on reference Series II BCRA tile set) |
| Effect Parameters |
/ |
| Effect Measurement |
/ |
| Effect Repeatability |
/ |
| Effect Reproducibility |
/ |
| Trigger mode |
Pressure sensing trigger, button trigger, software trigger |
| Measuring Mode |
Single measurement, average measurement (1-99), continuous measurement (1-99) |
| Locating Mode |
Color camera preview |
| Dimension |
7.7x83x5 inches (195x83x128mm) |
| Weight |
35 oz. (1Kg) |
| Power |
Lithium-ion battery, 3.7V,3200mAh, Continuous test 6000 times within 8 hours of full charge |
| Display |
3.5-inch TFT color LCD, Capacitive Touch Screen |
| Interface |
USB, Bluetooth |
| Data Storage |
1000 pcs Standards, 4000 pcs Samples |
| Language |
Simplified Chinese, Traditional Chinese, English |
| Operating Environment |
10℃ to 50℃, humidity does not exceed 85%, no condensation |
| Storage Environment |
-20℃ to 50℃, humidity does not exceed 85%, no condensation |
| Calibration |
Built-in white board parameters, external white board, black light trap |
| Calibration Interval |
4 hours,8 hours,24 hours,Startup calibration |
| Standard accessories |
Power Adapter, USB Cable, User Guide,PC Software(download from the official website), Calibration Board, black light trap,Protective cap, wristband |
| Optional Accessory |
Micro-printer |
| Notes |
Technical parameters are for reference only, subject to actual sales products. |