The UNI-T UDP5040-40 is a single-channel 400W programmable DC switching power supply delivering 0–40V and 0–40A with auto-ranging across the rated power envelope.

It pairs a wide output range with the regulation accuracy, source-emulation and remote control expected of a professional programmable supply.

Voltage accuracy is ±(0.05% of set + 0.05% of rated) and current accuracy ±(0.5% of set + 0.1% of rated); ripple is held to 50mV p-p with a 100 ppm/°C temperature coefficient. A 2.4-inch TFT-LCD shows voltage, current and power together, and full SCPI control over USB and LAN drops the UDP5040-40 straight into LabVIEW, Python-VISA or any ATE framework.

Choosing Your Model: UDP5000 Series

The UDP5000 name spans 20 models built on one platform: five voltage classes (40 V / 80 V / 160 V / 250 V / 800 V) across four power classes (400 W / 800 W / 1200 W / 2000 W). They differ only in output range and chassis size — control, accuracy, protection and interface are otherwise identical. Compare the full series before selecting:

Rated Power 40 V 80 V 160 V 250 V 800 V
400W UDP5040-40
0–40A
UDP5080-20
0–20A
UDP5160-8
0–8A
UDP5250-6
0–6A
UDP5800-2
0–2A
800W UDP5040-80
0–80A
UDP5080-40
0–40A
UDP5160-16
0–16A
UDP5250-12
0–12A
UDP5800-4
0–4A
1200W UDP5040-120
0–120A
UDP5080-60
0–60A
UDP5160-24
0–24A
UDP5250-18
0–18A
UDP5800-6
0–6A
2000W UDP5040-200
0–200A
UDP5080-100
0–100A
UDP5160-40
0–40A
UDP5250-30
0–30A
UDP5800-10
0–10A

Every model shares the same chassis architecture, control system, regulation accuracy, protection suite, and interface set. The 800 V UDP5800 tier does not support series connection; all other tiers support series and parallel combining. Choose by the voltage class that covers your rail and the power class that covers your load — output range and chassis height scale with power, the instrument does not change.

  • 400W / 0–40V / 0–40A — auto-ranging across the rated power envelope
  • Voltage accuracy ±(0.05% of set + 0.05% of rated); current accuracy ±(0.5% of set + 0.1% of rated)
  • Low ripple — 50mV p-p voltage, 80mA rms current (20 MHz BW)
  • CC/CV priority slope modes — choose voltage-first or current-first turn-on for DUT safety
  • Adjustable internal resistance to 1.000Ω — emulate batteries, fuel cells and solar sources
  • List Mode — 128 programmable V/I/dwell steps, 1 to 9,999, infinite cycles, stand-alone
  • Front and rear output terminals (front limited to 10 A)
  • Multi-unit series/parallel — up to 4 parallel / 4 series
  • USB + LAN with full SCPI 1999.0 / IEEE-488.2; 2.4-inch TFT-LCD
  • Discharge-load control for rapid output bleed-down

CC/CV Priority: Protect the Device, Not Just the Supply

Most bench supplies treat the CC/CV crossover as a fixed hardware behaviour. The UDP5000 lets you choose which parameter takes priority at turn-on and during mode transitions. CV-priority establishes the target voltage first — the right choice for microcontrollers, FPGAs and analog rails. CC-priority brings current up under control — the safer choice for LEDs, laser diodes and battery charging where inrush must be bounded.

Adjustable Slew Rate: Control How Fast Power Arrives

Internal Resistance: Simulate Real Power Sources

The internal variable-resistance function (set in CV mode, up to 1.000Ω in 1 mΩ steps) makes the terminal voltage droop with load current exactly as a battery, fuel cell or solar panel would — no physical resistor, no thermal risk, value changeable instantly from the panel or over SCPI.

Front & Rear Outputs: Bench-Ready and Rack-Ready

Output terminals are provided on both panels. Front terminals are there for quick prototype hookup; rear terminals keep permanent rack wiring clean. Both are the same single output — front-panel draw is limited to 10 A, so high-current loads belong on the rear.

List Mode & Discharge Control: Automate Output Sequences

List Mode runs up to 128 programmed V/I/dwell steps for 1 to 9,999, infinite cycles or continuously, stored locally or exported, executing with no PC attached — built for overnight burn-in, charge-profile runs and production routines. The internal discharge load bleeds output capacitance down rapidly when output is switched off.Voltage and current slew rates are independently settable. A slower ramp prevents inrush into capacitive loads, reduces mechanical stress on motor windings at start-up and gives sensitive analog circuits time to settle; the high-speed default mode is there when fast settling is what the test needs.

Multi-Unit Operation: Scale When You Need More

Up to 4 identical units parallel for more current, or up to 4 series for more voltage, coordinated over the rear CAN / LS_BUS interface from the master unit or a single SCPI connection; unit-to-unit balance stays within ~5% of rated.

Display and Control

A 2.4-inch TFT-LCD presents voltage, current and power simultaneously with a concise multifunction keypad; external analog control (0–10 V setpoint plus digital ON/OFF) is available on the rear analog interface for closed-loop and HIL setups.

Applications

Battery and Energy-Storage Test

The wide 0–40 V range covers 12 V to 36 V lithium-ion and LFP packs used in e-bike, power-tool and light-EV work. Internal-resistance emulation and List Mode let you reproduce charge profiles and varying pack states without cycling real cells.

New-Energy and Automotive Electronics

DC/DC converter input stages, inverter front ends and sub-40 V automotive ECUs benefit from the tight regulation, low ripple and CC/CV priority control.

Automated Test and Production

SCPI over USB or LAN plus stored List Mode sequences make the UDP5000 a clean fit for unattended characterisation, burn-in and end-of-line test.

Model UDP5040-40
Output Channels 1 (single channel)
Rated Output Voltage 0–40V
Rated Output Current 0–40A
Rated Output Power 400W
Maximum Adjustable Voltage 42V
Maximum Adjustable Current 42A
Voltage Setting Resolution 1mV
Current Setting Resolution 1mA
Voltage Display Resolution 1mV
Current Display Resolution 1mA
Voltage Output Accuracy ±(0.05% of set + 0.05% of rated)
Current Output Accuracy ±(0.5% of set + 0.1% of rated)
Voltage Load Regulation ±6mV
Voltage Line Regulation ±6mV
Current Load Regulation ±13mA
Current Line Regulation ±6mA
Voltage Ripple (p-p, 20 MHz BW) 50mV
Voltage Ripple (rms) 5mV
Current Ripple (rms) 80mA
Rise Time (rated load) <50ms
Fall Time (rated load) <50ms
Fall Time (no load) <500ms
Adjustable Internal Resistance (max) 1.000Ω
Remote Sense Compensation (max) 1.5V
Temperature Coefficient 100 ppm/°C
Preset Memory Groups 32
List Mode Groups 128
List Mode Step Time 0.1s to 99,999.9s
List Mode Cycles 1 to 9,999, infinite
Max Series-Connected Units 4
Max Parallel-Connected Units 4
Protection OVP, OCP, FOCP, OTP, Power Limit, Watchdog, Output ON/OFF Delayer
Remote Interface USB-Device, USB-Host, LAN, Analog I/O
SCPI / IEEE-488.2 Yes (SCPI 1999.0 + IEEE-488.2)
AC Input Voltage 85-265 Vac
AC Input Frequency 47-63 Hz
Efficiency (typ) 75%
Power Factor 0.99 @100Vac, 0.97 @200Vac
Display 2.4in TFT-LCD
Cooling Fan-forced air cooling
Operating Temperature 0°C to +50°C
Operating Humidity 20% to 85% R.H. (non-condensing)
Storage Temperature -20°C to +60°C
Max Altitude 2000m
Weight 3kg
Certifications CE


Included in the box:

  • Power cord
  • English download guide
  • multi-language safety manual
  • calibration report (COC)

Can I use the front and rear output terminals at the same time?

Both terminal sets are parallel connections to the same single output. You can wire both, but the front terminals are limited to 10 A maximum — route high-current loads to the rear panel.

What is the difference between the VHS/IHS and VSR/ISR slope modes?

VHS (CV high-speed) and IHS (CC high-speed) use the supply's default fast rise and fall rates. VSR (CV slope) and ISR (CC slope) let you set the rise and fall rate so output ramps in controlled fashion — useful for capacitive and motor loads, and for sensitive analog circuits that need settling time.

Does the internal-resistance function need an external resistor?

No. The internal variable-resistance function electronically emulates source impedance (set in CV mode, up to 1.000Ω in 1 mΩ steps), so the supply behaves like a battery, fuel cell or solar source with no physical resistor and no added thermal risk.

Can multiple units be combined for more power?

Yes. Identical models combine for more current (parallel, up to 4 units) or more voltage (series, up to 4 units), controlled from the master unit or a single SCPI connection; unit-to-unit balance stays within ~5% of rated.

How does it integrate with automated test?

USB and LAN with full SCPI 1999.0 / IEEE-488.2 support LabVIEW, Python-VISA and any standard ATE framework; List Mode runs stored sequences stand-alone without a connected PC.