PDM5219S-125V-250V-500V-Analog-Insulation-Tester-Portable-Insulation-Resistance-Meter | Sanwa-America.com
PDM5219S | 125V / 250V / 500V Analog Insulation Tester / Portable Insulation Resistance Meter - Sanwa-America.com
PDM5219S | 125V / 250V / 500V Analog Insulation Tester / Portable Insulation Resistance Meter - Sanwa-America.com
PDM5219S | 125V / 250V / 500V Analog Insulation Tester / Portable Insulation Resistance Meter - Sanwa-America.com
PDM5219S | 125V / 250V / 500V Analog Insulation Tester / Portable Insulation Resistance Meter - Sanwa-America.com
PDM5219S | 125V / 250V / 500V Analog Insulation Tester / Portable Insulation Resistance Meter - Sanwa-America.com


Sanwa

PDM5219S

PDM5219S | 125V / 250V / 500V Analog Insulation Tester / Portable Insulation Resistance Meter

Precio habitual $261.03 $0.00 Precio unitario por

The Sanwa PDM5219S is a lightweight Analog Insulation Tester with 3 test ranges of 125 / 250 / 500 Volts DC.

The PDM5219S is a DC insulation resistance tester to measure the insulation resistance of electric lines and electric equipment. The device’s main function is to measure insulation resistance and has a maximum insulation measuring range of 500V/ 100MΩ. It has 3 test voltage ranges DC500V/250V/125V.

The PDM5219S can not only measure insulation resistance it can also measure DC voltages (60 Volts, max), as well as AC voltages (600 Volts, max). Just like the Sanwa PDM1529S, the PDM5219S is also an IEC61010-1 CAT.III 600V certified and comes with an IP20 protection rating.

Meter includes test leads, carrying case with strap and instruction manual.

  • Test voltage DC500V/250V/125V
  • Easy viewing and readable scale graduations
  • One-shot or continuous measurement push switch
  • DCV measurement range (DC60V)
  • Auto discharge function
  • Inner battery check range
  • IEC61010-1 CAT.III 600V certified
  • IP20 Rated

        Specifications

        Scale (MΩ) 0.02~0.1~50~100MΩ
        500V/250V/125V
          Accuracy ± 5% of reading (1st effective measurement range : written in thick print above)
        ±10% of reading (2nd effective measurement range : written in small type above)
        ACV 600V
          Tolerance Within ±5% of the max. scale value(50~60Hz sine wave)
        DCV 60V
          Tolerance Within ±5% of the max. scale value
        Rated current 1.0~1.2mA
        Battery 6LF22/6LR61 (9V alkaline battery) x1
        Size/Mass H144×W99×D43 mm / Approx. 310g
        Safety standard IEC61010 CAT.Ⅲ 600V

        Compartir este producto


        A few of our valued customers: