| Model |
TS8510 (LED Light Source) |
| Optical Geometry |
Reflect: D/8 (diffused illumination, 8-degree viewing angle) ; |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; |
| Transmittance: D/0 (diffuse illumination: 0° viewing) ; |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; |
| HAZE (ASTM D1003); |
| Standards meet: CIE No.15, GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164,DIN5033 Teil7,JIS Z8722 under condition C |
| Characteristic |
1. Widely applied in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| 2. 10.5 inch rotatable display pad,128G storage, camera locating |
| 3. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures. |
| 4. Open transmission warehouse, available thickness of 54mm transmitted samples. |
| 5. Automatic temperature and humidity compensation function. |
| Integrating Sphere Size |
Φ154mm |
| Light Source Device |
360nm–780nm Wavelength range, combined LED Light. Including UV, 400nm cut-off light source, 420nm Cut-off light source, 460nm Cut-off light source |
| Spectrophotometric Mode |
Concave Grating |
| Sensor |
256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range |
360~780nm |
| Wavelength Interval |
10nm |
| Semiband Width |
5nm |
| Measured Reflectance Range |
0~200% |
| Reflectivity Resolution |
0.01 |
| Measuring Aperture |
Reflective: |
XLAV Φ25.4mm/Φ30mm, LAVΦ15mm/Φ18mm , MAVΦ8mm/Φ10mm, SAVΦ4mm/Φ6mm |
| Transmissive: |
| Φ25.4mm(No limit on sample height and width, but thickness≤54mm) |
| Remark: |
| 1. Automatic identification of aperture switch |
| 2. Customized Configuration caliber and lens position |
| Specular Component |
Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space |
CIE LAB,XYZ,Yxy,LCh,CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
| Color Difference Formula |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99, ΔE(Hunter), ΔE*CH, 555 Index |
| Other Colorimetric Index |
WI(ASTM E313,CIE/ISO,AATCC,Hunter, Taube, Berger Stensby) |
| YI(ASTM D1925,ASTM 313),ISO brightness,R457 |
| MI (Metamerism Index), |
| Staining Fastness, Color Fastness, Color Strength, Opacity, |
| APHA/Hazen/Pt-Co Index,Gardner Index |
| Haze, Transmission(ASTM D1003), Saybolt index, ASTM D1500 Color code, 8° Gloss, 555 Index, carbon(My,dM),Color density CMYK(A,T,E,M), Tint, Color density(part function achieved via software in PC) |
| Observer Angle |
2°/10° |
| Illuminant |
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF |
| ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total, part achieved via software in PC) |
| Displayed Data |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity |
| Measuring Timed |
2.0s(Measure SCI & SCE meantime about 4s ) |
| Repeatability |
Reflectance chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration); |
| spectrum reflectance /transmission:≤0.1% |
| Inter-instrument Error |
Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Dimension |
17.3 x 9.75 x 11.1 inches (440 x 248 x 283 mm) |
| Weight |
30 lbs. (Approx. 13.5kg) |
| Power |
AC 24V, 3A Power adapter power supply |
| Illuminant Life Span |
5 years, more than 3 million times measurements |
| Display |
10.5-inch rotatable Display Pad |
| Data Port |
USB & Bluetooth 5.0 |
| Data Storage |
64G storage, above 100,000pcs |
| Language |
Simplified Chinese, Traditional Chinese, English, (Optional Customized German,Russian, French , Spanish, Japanese, Thai, Korean, Polish, Portuguese) |
| Operating Environment |
0~40℃(32~104°F) |
| Storage Environment |
-20~50℃(-4~122°F) |
| Standard Accessory |
Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette, 10.5-inch screen |
| Optional Accessory |
Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture |
| Notes |
Test reports can be printed through a network printer connected to a PC or display pad, The specifications are subject to change without notice. |