Desktop TVOC Indoor Air Quality Monitor
Download
Download
This desktop VOC monitor offers real-time detection of indoor mixed gases with high sensitivity to total volatile organic compounds (TVOC).
Note: All Tongdy monitors and controls ship direct from the factory. Please allow 10-15 business days for shipping and handling.
It simultaneously displays temperature and humidity, providing a comprehensive overview of indoor air conditions. The device features a three-color backlit LCD that clearly indicates air quality levels, accompanied by a selectable buzzer alarm for immediate alerts. An optional on/off output allows integration with a ventilator for automated air control, and an RS485 interface is available for advanced connectivity. Its intuitive display and warning system enable precise air quality management to maintain a healthy environment. The unit includes a handheld remote controller for parameter setup and additional functionality.
-
Real-time monitoring of TVOC, temperature and humidity for complete indoor air quality insight
-
Built-in semiconductor mixed-gas sensor with 5-year lifespan for long-term reliability
-
Detects a wide range of harmful gases, including cigarette smoke, VOCs (formaldehyde, toluene), ethanol, ammonia, hydrogen sulfide, sulfur dioxide and more
-
Clear LCD display shows current readings plus a one-hour moving average for accurate trend analysis
-
Six-color backlight system aligned with PM2.5 AQI standards for intuitive visual air quality indication
-
Three-level color alarm (green/orange/red) with buzzer warning for quick response to poor air conditions
-
Provides one relay output to control a ventilator or other air-handling equipment
-
Optional Modbus RS485 communication for seamless integration into building management systems
-
Flexible design for desktop use or wall mounting in residential, commercial, and industrial settings
- Remote control included for parameter setup and additional functionality
Specifications
|
Gas detection |
Highly sensitive to many harmful gases, such as harmful gases from construction and decoration materials, VOCs (like toluene and formaldehyde); Cigarette smoke; Ammonia and H2S and other gases from household wastes; CO, SO2 from cooking and burning; Alcohol, Natural gas, detergent and other bad smells etc. |
|
| Sensing element | Semiconductor mix gas sensor of long working life and good stability | |
| Signal update | 1s | |
| Warm up time | 72 hours (first time), 1 hour (normal operation) | |
| VOC measuring range | 1~30ppm ( 1ppm= 1 part per million | |
| Display resolution | 0.1ppm | |
| VOC setting resolution | 0.1ppm | |
| Temperature & Humidity Sensor | Temperature | Relative Humidity |
| Sensing element | NTC 5K | Capacitive sensor |
| Measuring range | 0~50℃ | 0 -95%RH |
| Accuracy | ±0.5℃ (25℃, 40%-60%RH) | ±4%RH (25℃, 40%-60%RH) |
| Display resolution | 0.5℃ | 1%RH |
| Stability | ±0.5℃per year | ±1%RH per year |
| Output | 1xRelay output to control a ventilator or air-purifier,
max current 3A resistance(220VAC) |
|
| Warning alarm | Inner buzzer alarm and also three colors backlit switch as well | |
| Buzzer alarm | Alarm starts when VOC value above 25ppm | |
|
LCD backlit |
Green—optimal air quality ► enjoy the air quality
Orange—moderate air quality ► ventilation suggested Red—-poor air quality ► ventilation immediately |
|
| RS485 interface (optional) | Modbus protocol with 19200bps |
| Operating condition | -20℃~60℃ (-4℉~140℉)/ 0~ 95% RH |
| Storage conditions | 0℃~50℃ (32℉~122℉)/ 5~ 90% RH |
| Net Weight | 190g |
| Dimensions | 130mm(L)×85mm(W)×36.5mm(H) |
| Installation standard | Desktop (65mm×65mm or 85mmX85mm or 2”×4” wire box) |
| Wiring standard | Wire section area <1.5mm2 |
| Power supply | 24VAC/VDC,230VAC |
| Consumption | 2.8 W |
| Quality System | ISO 9001 |
| Housing | PC/ABS fire-proof, IP30 protection |
| Certificate | CE |
Downloads
Couldn't load pickup availability
Product Information
Product Information
This desktop VOC monitor offers real-time detection of indoor mixed gases with high sensitivity to total volatile organic compounds (TVOC).
Note: All Tongdy monitors and controls ship direct from the factory. Please allow 10-15 business days for shipping and handling.
It simultaneously displays temperature and humidity, providing a comprehensive overview of indoor air conditions. The device features a three-color backlit LCD that clearly indicates air quality levels, accompanied by a selectable buzzer alarm for immediate alerts. An optional on/off output allows integration with a ventilator for automated air control, and an RS485 interface is available for advanced connectivity. Its intuitive display and warning system enable precise air quality management to maintain a healthy environment. The unit includes a handheld remote controller for parameter setup and additional functionality.
-
Real-time monitoring of TVOC, temperature and humidity for complete indoor air quality insight
-
Built-in semiconductor mixed-gas sensor with 5-year lifespan for long-term reliability
-
Detects a wide range of harmful gases, including cigarette smoke, VOCs (formaldehyde, toluene), ethanol, ammonia, hydrogen sulfide, sulfur dioxide and more
-
Clear LCD display shows current readings plus a one-hour moving average for accurate trend analysis
-
Six-color backlight system aligned with PM2.5 AQI standards for intuitive visual air quality indication
-
Three-level color alarm (green/orange/red) with buzzer warning for quick response to poor air conditions
-
Provides one relay output to control a ventilator or other air-handling equipment
-
Optional Modbus RS485 communication for seamless integration into building management systems
-
Flexible design for desktop use or wall mounting in residential, commercial, and industrial settings
- Remote control included for parameter setup and additional functionality
Specifications
|
Gas detection |
Highly sensitive to many harmful gases, such as harmful gases from construction and decoration materials, VOCs (like toluene and formaldehyde); Cigarette smoke; Ammonia and H2S and other gases from household wastes; CO, SO2 from cooking and burning; Alcohol, Natural gas, detergent and other bad smells etc. |
|
| Sensing element | Semiconductor mix gas sensor of long working life and good stability | |
| Signal update | 1s | |
| Warm up time | 72 hours (first time), 1 hour (normal operation) | |
| VOC measuring range | 1~30ppm ( 1ppm= 1 part per million | |
| Display resolution | 0.1ppm | |
| VOC setting resolution | 0.1ppm | |
| Temperature & Humidity Sensor | Temperature | Relative Humidity |
| Sensing element | NTC 5K | Capacitive sensor |
| Measuring range | 0~50℃ | 0 -95%RH |
| Accuracy | ±0.5℃ (25℃, 40%-60%RH) | ±4%RH (25℃, 40%-60%RH) |
| Display resolution | 0.5℃ | 1%RH |
| Stability | ±0.5℃per year | ±1%RH per year |
| Output | 1xRelay output to control a ventilator or air-purifier,
max current 3A resistance(220VAC) |
|
| Warning alarm | Inner buzzer alarm and also three colors backlit switch as well | |
| Buzzer alarm | Alarm starts when VOC value above 25ppm | |
|
LCD backlit |
Green—optimal air quality ► enjoy the air quality
Orange—moderate air quality ► ventilation suggested Red—-poor air quality ► ventilation immediately |
|
| RS485 interface (optional) | Modbus protocol with 19200bps |
| Operating condition | -20℃~60℃ (-4℉~140℉)/ 0~ 95% RH |
| Storage conditions | 0℃~50℃ (32℉~122℉)/ 5~ 90% RH |
| Net Weight | 190g |
| Dimensions | 130mm(L)×85mm(W)×36.5mm(H) |
| Installation standard | Desktop (65mm×65mm or 85mmX85mm or 2”×4” wire box) |
| Wiring standard | Wire section area <1.5mm2 |
| Power supply | 24VAC/VDC,230VAC |
| Consumption | 2.8 W |
| Quality System | ISO 9001 |
| Housing | PC/ABS fire-proof, IP30 protection |
| Certificate | CE |
Downloads
Description
Description
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Category: Volatile Organic Compound (VOC) Meters
A few of our valued customers:

