DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V - Sanwa-America.com
DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V - Sanwa-America.com
DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V - Sanwa-America.com
DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V - Sanwa-America.com


Sanwa

DCM2000DR

DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V

Normaler Preis $318.00 $0.00 Einzelpreis pro

The Sanwa DCM2000DR is a digital clamp meter with digital multimeter capabilities.

The DCM2000DR is an AC/DC clamp meter/digital multimeter of the RMS value response type, designed for measurements in the range specified by IEC61010-1 CAT.IV 1000V. It is suitable for current and voltage measurements of low-voltage circuitry, electric equipment, and power supply facilities. 

This instrument is capable of measuring both AC and DC currents and voltages. As the device also functions as a multimeter, it can perform a variety of functions such as measuring resistances, frequency, capacitances, performing diode tests as well as continuity tests with buzzer alarms.

The device can also measure electric field strength and features a low pass filter for VFD (Variable Frequency Drive) AC voltage measurement. The DCM2000DR has data hold, range hold and peak hold functions as well. The device is power efficient and features an auto power save feature that turns off the display after 34 minutes of inactivity (cancellable).

Includes meter, one set of test leads, carrying case and instructions.

  • AC/DC current measurable max. 2000A & DMM function
  • True RMS
  • 6000 Count Digital Display with Backlight
  • Dual display shows voltage/current and its frequency
  • EF (Electric Field) sensing
  • VFD (Variable Frequency Drive) frequency measurement
  • Low input impedance voltage measurement capable of attenuating the effects of ghost voltage
  • Data hold / Range hold / Peak hold (5ms)
  • Relative value
  • Auto power save (34min after the last operation) (cancelable)

                            Specifications

                            Function Range Accuracy Resolution
                            ACA 200.0/2000A ±(2.0%+5) 0.1A
                            DCA 200.0/2000A ±(2.0%+5) 0.1A
                            ACV 6.000/60.00/600.0/1000V ±(1.2%+5) 0.001V
                            DCV 6.000/60.00/600.0/1000V ±(0.5%+5) 0.001V
                            Resistance 600.0/6.000k/60.00k/600.0k/6.000M/40.00MΩ ±(0.5%+5) 0.1Ω
                            Frequency 10~1999Hz ±(0.1%+4) 0.01Hz
                            Capacitance 60n/600n/6μ/60μ/600μ/2000μF ±(2.0%+5) 0.01nF
                            Continuity Buzzer sounds at below 10-200Ω Open voltage: approx. 0.5V
                            Diode test Open voltage: approx. 1.8V
                            EF sensing A voltage or electric field of about 60 V or more is detected. The barr graph and intermittent buzzer beeps change in three steps according to the field intensity. (50/60Hz)
                            Sampling rate Approx. 5 times/sec.
                            Bandwidth 50~400Hz
                            Display 6000/1999(Hz)
                            Max. overload protection input DC/AC1100V
                            CT: DC/AC2000A
                            Clamp diameter/Conductor size Φ55mm/20x66mm
                            Battery R6Px2
                            Battery life A function: Approx. 80 hrs. Functions other than A: Approx. 240 hrs. (Zinc-carbon battery/Backlight off)
                            Size/Mass H264×W97×D43mm/Approx. 640g
                            Safety standards IEC61010 CAT Ⅳ 1000V

                            Diesen Artikel teilen


                            A few of our valued customers: