{"product_id":"ultrasonic-thickness-gauge","title":"UCT-180B Ultrasonic Thickness Gauge","description":"\u003ch1\u003e\u003cspan\u003e\u003cb\u003ePortable High-Precision Thickness Measurement for Industrial NDT Applications\u003c\/b\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll BRK meters and probes ship direct from the \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003emanufacturer and\u003c\/span\u003e require 10-15 business days for shipping.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTHe BRK UCT-180B Ultrasonic Thickness Gauge is a rugged, high-accuracy portable instrument designed for non-destructive thickness measurement across a wide range of materials including metals, plastics, ceramics and composites.\u003c\/strong\u003e Built with a durable all-metal housing, the UCT-180B is engineered for reliable performance in harsh industrial environments while delivering fast and repeatable measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePowered by advanced microprocessor technology, the unit provides precise thickness readings, sound velocity measurement and multi-probe flexibility, making it ideal for corrosion monitoring, quality control and field inspection.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWide measurement range up to 500 mm depending on probe configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh resolution of 0.01 mm for precise thickness readings\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdvanced microprocessor for fast and stable measurement performance\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDurable all-metal sealed housing for harsh environments\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with multiple probes including standard, micro-diameter and high-temperature (comes with standard 10mm general purpose probe.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto probe recognition and calibration for simplified operation\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData storage capacity up to 2000 readings\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB connectivity for data export and reporting\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong battery life exceeding 200 hours with power-saving modes\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBacklit display for visibility in low-light environments\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-description\" style=\"text-align: start;\"\u003e\n\u003ch3\u003eMeasurement Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteel, stainless steel and cast iron\u003c\/li\u003e\n\u003cli\u003eAluminum, copper and alloys\u003c\/li\u003e\n\u003cli\u003ePlastics, glass and composites\u003c\/li\u003e\n\u003cli\u003eCorroded and coated materials\u003c\/li\u003e\n\u003cli\u003ePipes, tanks and structural components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePipeline corrosion monitoring\u003c\/li\u003e\n\u003cli\u003ePressure vessels and boilers\u003c\/li\u003e\n\u003cli\u003eMarine inspection\u003c\/li\u003e\n\u003cli\u003eAerospace and automotive\u003c\/li\u003e\n\u003cli\u003eManufacturing quality control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain unit\u003c\/li\u003e\n\u003cli\u003eStandard 10mm probe\u003c\/li\u003e\n\u003cli\u003eCalibration block\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.65 – 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mm (\u0026lt;10 mm), ±(0.5%H + 0.01 mm) (\u0026gt;10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Velocity Range\u003c\/td\u003e\n\u003ctd\u003e1000 – 9999 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003eSingle and Scan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd\u003e4 readings\/sec (single), 10 readings\/sec (scan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e2000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003emm \/ inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-30°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e4.0 mm steel reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eProbe Options\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProbe Type\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eFrequency\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eDiameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eRange\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard (included) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 – 500 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral purpose\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicro \/ Thin Wall\u003c\/td\u003e\n\u003ctd\u003e7 MHz\u003c\/td\u003e\n\u003ctd\u003e4 or 6 mm\u003c\/td\u003e\n\u003ctd\u003e0.65 – 260 mm\u003c\/td\u003e\n\u003ctd\u003eThin materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoarse Grain\u003c\/td\u003e\n\u003ctd\u003e2–5 MHz\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003ctd\u003eUp to 500 mm\u003c\/td\u003e\n\u003ctd\u003eCast materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Temp\u003c\/td\u003e\n\u003ctd\u003e5 MHz\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003ctd\u003e3 – 200 mm\u003c\/td\u003e\n\u003ctd\u003eUp to 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"BRK UCT-180 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UCT-180_Series_Ultrasonic_Thickness_Gauge.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"BRK UCT-180 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UCT-180_Series_Ultrasonic_Thickness_Gauge.pdf\" target=\"_blank\"\u003eBRK UCT-180 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UCT_Series_Ultrasonic_Thickness_Gauge.pdf\" title=\"BRK UCT-180 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UCT_Series_Ultrasonic_Thickness_Gauge.pdf\" title=\"BRK UCT-180 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eBRK UCT-180 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eComparison Chart\u003c\/h4\u003e\n\u003ch3\u003eCompare Ultrasonic Thickness Gauges\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 342px;\" class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003cth style=\"text-align: left; width: 15.753119%; height: 19px;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"width: 24.863525%; height: 19px; text-align: left;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/ultrasonic-thickness-gauge\" rel=\"noopener\" target=\"_blank\"\u003eUCT-180B\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"width: 32.294452%; height: 19px; text-align: left;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/uct-180c-ultrasonic-thickness-gauge\"\u003eUCT-180C\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"width: 22.103387%; height: 19px; text-align: left;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/materials-non-destructive-testing\/products\/ultrasonic-precision-thickness-gauge\" rel=\"noopener\" target=\"_blank\"\u003ePMT-360 Series\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 57px;\"\u003eBest For\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 57px;\"\u003eField inspection, corrosion testing\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 57px;\"\u003eEnhanced inspection with coating capability\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 57px;\"\u003eAdvanced analysis, lab + field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 38px;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 38px;\"\u003e0.65 – 500 mm\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 38px;\"\u003e0.65 – 500 mm\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 38px;\"\u003e0.05 – 2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 19px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 19px;\"\u003e0.01 mm\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 19px;\"\u003e0.01 mm\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 19px;\"\u003eUp to 0.0001 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 38px;\"\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 38px;\"\u003eBasic + Scan\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 38px;\"\u003ePulse-Echo + Echo-Echo\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 38px;\"\u003eE-E, P-E, Coating, Multi-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 38px;\"\u003eThrough Coating\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 38px;\"\u003eLimited\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 38px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 38px;\"\u003eYes (advanced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 38px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 38px;\"\u003eStandard LCD\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 38px;\"\u003eEnhanced LCD\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 38px;\"\u003eA-scan + B-scan waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 19px;\"\u003eData Storage\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 19px;\"\u003e2000 readings\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 19px;\"\u003e10,000 readings (typical)\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 19px;\"\u003eUp to 1TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 19px;\"\u003eEase of Use\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 19px;\"\u003eVery easy\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 19px;\"\u003eEasy with added features\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 19px;\"\u003eAdvanced user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 19px;\"\u003ePrice Tier\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 19px;\"\u003e$$\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 19px;\"\u003e$$$\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 19px;\"\u003e$$$$\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 15.753119%; height: 38px;\"\u003eIdeal Buyer\u003c\/td\u003e\n\u003ctd style=\"width: 24.863525%; height: 38px;\"\u003eTechnicians, inspectors\u003c\/td\u003e\n\u003ctd style=\"width: 32.294452%; height: 38px;\"\u003eInspectors needing coating measurement\u003c\/td\u003e\n\u003ctd style=\"width: 22.103387%; height: 38px;\"\u003eEngineers, NDT specialists\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eProbes\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UCT-180B-6_600x600.jpg\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003ch4\u003e Probe Comparison\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Probes for UCT-180 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UCT-180_Probes_600x600.png?v=1776292362\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BRK","offers":[{"title":"Default Title","offer_id":50129217814752,"sku":"UCT-180B","price":367.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/ultrasonic-thickness-gauge-uct-180b-2935544.jpg?v=1787082101","url":"https:\/\/sperdirect.com\/products\/ultrasonic-thickness-gauge","provider":"Sper Scientific Direct","version":"1.0","type":"link"}