{"product_id":"thermocouple-extension-coiled-types-j-k-t","title":"Thermocouple Extension - Coiled - Types J\/K\/T","description":"\u003ch1\u003eThermocouple coiled extension wire is used to carry the signal from the thermocouple sensor to the readout device while maintaining a high degree of accuracy. \u003c\/h1\u003e\n\u003cp\u003eThe extension wire material must match the material used in the positive and negative leg of the thermocouple type (e.g. type K) being used in the application. If a transmitter is installed within the thermocouple sensor assembly, copper wire is typically used in place of thermocouple extension wire to send the scalable (4 to 20) mA signal back to the process control equipment.\u003c\/p\u003e\n\u003cp\u003eWe offer a variety of sizes and gauges of thermocouple grade and extension wire, as well as wire insulators. We also offer special construction thermocouple wire and RTD cable, including multi-pair thermocouple extension wire.\u003c\/p\u003e\n\u003cp\u003eThermocouple and extension wires are generally ordered and specified by ASTM\/ANSI designations for calibration.\u003c\/p\u003e\n\u003cp\u003ePopular generic and trade name examples are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChromel®\/Alumel® - ASTM\/ANSI Type K\u003c\/li\u003e\n\u003cli\u003eIron\/Constantan - ASTM\/ANSI Type J\u003c\/li\u003e\n\u003cli\u003eCopper\/Constantan - ASTM\/ANSI Type T\u003c\/li\u003e\n\u003cli\u003eChromel®\/Constantan - ASTM\/ANSI Type E\u003c\/li\u003e\n\u003cli\u003eNicrosil®\/Nisil® - ASTM\/ANSI Type N\u003c\/li\u003e\n\u003cli\u003ePlatinum\/Platinum (10% Rhodium) - ASTM\/ANSI Type S\u003c\/li\u003e\n\u003cli\u003ePlatinum\/Platinum (13% Rhodium) - ASTM\/ANSI Type R\u003c\/li\u003e\n\u003cli\u003ePlatinum (6% Rhodium)\/Platinum (30% Rhodium) - ASTM\/ANSI Type B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePyromation produces a wide range of thermocouples and thermocouple replacements for most market applications, including MgO (Magnesium Oxide), industrial and general-purpose types. We also make thermocouple assemblies for hazardous locations and other applications that require connection heads, protection tubes, thermowells and\/or transmitters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll \u003c\/span\u003e\u003cspan style=\"caret-color: rgb(255, 42, 0); color: rgb(255, 42, 0);\"\u003ePyromation\u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e products are built to order and typically ship 2-4 business days after we \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ereceive \u003c\/span\u003eyour order.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eIf you have a specific requirement or need a thermocouple you don't see listed just \u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/pages\/contact-us\" target=\"_blank\"\u003esend us a note\u003c\/a\u003e and we'll get you a quote.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable width=\"899\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"bottom\" width=\"99\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"513\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd nowrap width=\"132\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"66\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003ePlug Color\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"89\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRelaxed length\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"bottom\" width=\"99\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eTE5-C3060-6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"513\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eType T, Extension, Coil Cord, Standard Female Jack, Mini Plug, 60\" Max Extension\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"132\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e105C Continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"66\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eBlue\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"89\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e12\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"bottom\" width=\"99\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eJE5-C3060-6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"513\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eType J, Extension, Coil Cord, Standard Female Jack, Mini Plug, 60\" Max Extension\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"132\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e105C Continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"66\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"89\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e12\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"bottom\" width=\"99\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eKE5-C3060-6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"513\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eType K, Extension, Coil Cord, Standard Female Jack, Mini Plug, 60\" Max Extension\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"132\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e105C Continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"66\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eYellow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" width=\"89\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e12\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca rel=\"noopener\" title=\"Thermocouple Temperature Limits and Color Codes\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Thermocouple_Temperature_Limits_and_Color_Codes.pdf\" target=\"_blank\"\u003e\u003cimg style=\"margin-right: 16px; margin-bottom: 16px; float: left;\" alt=\"Thermocouple Temperature Limits and Color Codes\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63.png?v=1613706188\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"Thermocouple Temperature Limits and Color Codes\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Thermocouple_Temperature_Limits_and_Color_Codes.pdf\" target=\"_blank\"\u003eThermocouple Temperature Limits and Color Codes\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca rel=\"noopener\" title=\"Thermocouple Initial Material Tolerances\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Thermocouple_Initial_Material_Tolerances.pdf\" target=\"_blank\"\u003e\u003cimg style=\"margin-right: 16px; margin-bottom: 16px; float: left;\" alt=\"Thermocouple Temperature Limits and Color Codes\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63.png?v=1613706188\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca rel=\"noopener\" title=\"Thermocouple Initial Material Tolerances\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Thermocouple_Initial_Material_Tolerances.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eThermocouple Initial Material Tolerances\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/General_MgO_Specifications.pdf\" title=\"General MgO Specifications\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"General MgO Specifications\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63.png?v=1613706188\" style=\"margin-right: 16px; margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/General_MgO_Specifications.pdf\" title=\"General MgO Specifications\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eGeneral MgO Specifications\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/j7eZ2vR1OUM?si=cWydWCem7Nb_tau7\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Pyromation","offers":[{"title":"TE5-C3060-6 | Type T, Extension, Coiled Cord, Standard Female Jack, Mini Plug, 60\" Max Extension","offer_id":47723690918112,"sku":"TE5-C3060-6","price":61.38,"currency_code":"USD","in_stock":true},{"title":"JE5-C3060-6 | Type J, Extension, Coiled Cord, Standard Female Jack, Mini Plug, 60\" Max Extension","offer_id":47723690950880,"sku":"JE5-C3060-6","price":60.28,"currency_code":"USD","in_stock":true},{"title":"KE5-C3060-6 | Type K, Extension, Coiled Cord, Standard Female Jack, Mini Plug, 60\" Max Extension","offer_id":47723702190304,"sku":"KE5-C3060-6","price":61.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/thermocouple-extension-coiled-types-jkt-te5-c3060-6-6452464.jpg?v=1758657352","url":"https:\/\/sperdirect.com\/products\/thermocouple-extension-coiled-types-j-k-t","provider":"Sper Scientific Direct","version":"1.0","type":"link"}