{"product_id":"industrial-dissolved-oxygen-bioprocess-monitor","title":"Industrial Dissolved Oxygen Bioprocess Monitor","description":"\u003ch1\u003eIndustrial Dissolved Oxygen Monitor is ideal for effluent treatment, pure water, boiler water, surface water, electroplating, chemical processing, pharmaceuticals, food production, environmental monitoring, breweries and fermentation applications.\u003c\/h1\u003e\n\u003cp\u003eFeatures a large dot-matrix display with intuitive operation interface designed for ease of use. Built-in data storage, viewing, and export functions with configurable storage cycles. RS485 network connectivity enables remote monitoring across multiple locations. Advanced lightning protection safeguards equipment reliability in demanding environments. Firmware supports online upgrades for simplified maintenance and feature updates. Flexible mounting options accommodate panel, wall or pipe installation to fit your facility layout.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge dot-matrix display with intuitive interface for straightforward operation and clear visibility.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in data storage, viewing, and export capabilities with user-configurable storage cycles.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRS485 interface enables network monitoring and remote oversight across multiple locations.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced lightning protection design ensures reliable equipment performance in industrial environments.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFirmware supports online upgrades for convenient maintenance and system enhancements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 200.0%\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00 ppm; 0.0 to 200.0 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e0.01\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2\u003c\/td\u003e\n\u003ctd\u003e±0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePt 1000\/NTC22K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10.0 to +130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10.0 to +130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Current Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-2.0 to +400 nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Current Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.005 nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarization\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0.675 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 to 9999 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 50.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBacklit dot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Current Output 1\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIsolated 4–20 mA output; maximum load 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Current Output 2\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIsolated 4–20 mA output; maximum load 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eModbus RTU protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9600\/19200\/38400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relay Contact Capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 A at 250 VAC; 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning Setting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eON: 1–1000 seconds; OFF: 0.1–1000.0 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne Multifunction Relay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCleaning\/period alarm\/error alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Delay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0–120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage Selection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEnglish, traditional Chinese and simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof Grade\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90–260 VAC; power consumption \u0026lt;5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePanel, wall or pipe installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":67893279260896,"sku":"SSMDO-100","price":786.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/industrial-dissolved-oxygen-bioprocess-monitor-ssmdo-100-4054598.jpg?v=1791990915","url":"https:\/\/sperdirect.com\/products\/industrial-dissolved-oxygen-bioprocess-monitor","provider":"Sper Scientific Direct","version":"1.0","type":"link"}