{"product_id":"high-temperature-ph-sensor-with-vp-connector","title":"Online High-Temperature pH Sensor with VP Connector","description":"\u003ch1\u003eThis high-temperature pH sensor supports online pH and temperature monitoring in processes that use clean-in-place and sterilize-in-place cycles.\u003c\/h1\u003e\n\u003cp\u003eDesigned for fermentation, biotechnology, pharmaceutical manufacturing and food processing, the sensor measures 0–14 pH and operates at temperatures up to 130 °C. A double-junction electrode design supports industrial measurement through the temperature changes associated with cleaning and sterilization.\u003c\/p\u003e\n\u003cp\u003eThe VP connection works with compatible VP6 cabling, while the PG13.5 process thread supports installation with a suitable holder or sheath. Choose a T or Y configuration in 120, 150, 225 or 325 mm electrode lengths to match your process installation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOnline pH and temperature monitoring for high-temperature processes\u003c\/li\u003e\n\u003cli\u003eSuitable for applications using CIP and SIP procedures\u003c\/li\u003e\n\u003cli\u003eVP electrical connection and PG13.5 process thread\u003c\/li\u003e\n\u003cli\u003e12 mm electrode diameter\u003c\/li\u003e\n\u003cli\u003eFour electrode lengths and two configuration choices\u003c\/li\u003e\n\u003cli\u003eCompatible with suitable 316L stainless steel sheaths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 313.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003epH and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003ePublished pH accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e0–130 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e0–0.6 MPa (0–6 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eElectrical connector\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003eVP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eCompatible cable\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003eVP6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eProcess thread\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003ePG13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eElectrode diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eAvailable electrode lengths\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003e120, 150, 225 and 325 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003ePt1000 or 10 kΩ, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eReference system\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003eDouble liquid junction; electrolyte configuration depends on the selected version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cp\u003ePlease \u003ca href=\"https:\/\/sperdirect.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e for the product datasheet and installation guidance.\u003c\/p\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cp\u003eSelect the T or Y configuration and required electrode length. Contact us for help matching the reference system and temperature compensation element to your analyzer and process.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eLength\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eT Configuration\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eY Configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e120 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-120\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e150 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-150\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e225 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-225\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e325 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-1325\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eVP6-compatible cabling and suitable 316L stainless steel sheaths support analyzer and process connections. Photos show a representative electrode length and compatible cable. Confirm cable and mounting hardware requirements with your order.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum operating temperature?\u003c\/strong\u003e\u003cbr\u003eThe specified operating range is 0–130 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich connector does this listing use?\u003c\/strong\u003e\u003cbr\u003eAll eight variants use a VP electrical connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich electrode lengths are available?\u003c\/strong\u003e\u003cbr\u003eChoose 120, 150, 225 or 325 mm in either T or Y configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere can this sensor be used?\u003c\/strong\u003e\u003cbr\u003eTypical applications include fermentation vessels, bioreactors, pharmaceutical production and food or beverage processing.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"T \/ 120 mm","offer_id":68330364010720,"sku":"870002-HPHT-120","price":472.0,"currency_code":"USD","in_stock":true},{"title":"T \/ 150 mm","offer_id":68330364043488,"sku":"870002-HPHT-150","price":622.5,"currency_code":"USD","in_stock":true},{"title":"T \/ 225 mm","offer_id":68330364076256,"sku":"870002-HPHT-225","price":747.5,"currency_code":"USD","in_stock":true},{"title":"T \/ 325 mm","offer_id":68330364109024,"sku":"870002-HPHT-325","price":872.5,"currency_code":"USD","in_stock":true},{"title":"Y \/ 120 mm","offer_id":68330364141792,"sku":"870002-HPHY-120","price":472.0,"currency_code":"USD","in_stock":true},{"title":"Y \/ 150 mm","offer_id":68330364174560,"sku":"870002-HPHY-150","price":622.5,"currency_code":"USD","in_stock":true},{"title":"Y \/ 225 mm","offer_id":68330364207328,"sku":"870002-HPHY-225","price":747.5,"currency_code":"USD","in_stock":true},{"title":"Y \/ 325 mm","offer_id":68330364240096,"sku":"870002-HPHY-325","price":872.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-high-temperature-ph-sensor-with-vp-connector-870002-hpht-120-7278134.jpg?v=1793360773","url":"https:\/\/sperdirect.com\/fr-ca\/products\/high-temperature-ph-sensor-with-vp-connector","provider":"Sper Scientific Direct","version":"1.0","type":"link"}