{"product_id":"online-water-total-hardness-analyzer","title":"Online Water Total Hardness Analyzer","description":"\u003cdiv id=\"unit-jJRg30pax7IDugk\" type=\"text\"\u003e\n\n\u003cdiv class=\"ce-text_item\"\u003e\n\n\u003cdiv class=\"ce-text\"\u003e\n\n\u003ch1\u003ePagsusuri ng Kabuuang Katigasan ng Tubig sa Real-Time\u003cbr\u003e\n\n\u003c\/h1\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv id=\"unit-dp0xU9KXb5h4sOF\" type=\"text\"\u003e\n\n\u003cdiv class=\"ce-text_item\"\u003e\n\n\u003cdiv class=\"ce-text\"\u003e\n\n\u003cp\u003eAng Online Water Total Hardness Analyzer ay isang mahalagang kagamitan para sa pagsubaybay sa kabuuang katigasan (total hardness) o carbonate hardness at kabuuang alkali ng tubig sa pamamagitan ng ganap na awtomatikong paraan ng titrasyon.\u003c\/p\u003e\n\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\n\u003cdiv class=\"ce-list_text\"\u003e\n\n\u003cdiv class=\"ce-list_summary\"\u003e\n\n\u003cul\u003e\n\n\u003cli class=\"ce-summary\"\u003e\u003cspan\u003eMaaasahan, tumpak, at ganap na awtomatikong pagsusuri ng katigasan at alkali.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli class=\"ce-summary\"\u003eSimpleng komisyon gamit ang configuration assistant.\u003c\/li\u003e\n\n\u003cli class=\"ce-summary\"\u003e\u003cspan\u003eMay sariling kalibrasyon at pagsubaybay na may mataas na antas ng katumpakan sa pagsukat.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMadaling pagpapanatili at paglilinis.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMinimal na paggamit ng reagent at tubig.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMulti-colored at multi-lingual na graphic display.\u003c\/span\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp\u003eSa mga saklaw ng pagsukat para sa katigasan mula 0.5-534ppm, at kabuuang alkali mula 5.34-401ppm, ang aparatong ito ay nagbibigay ng tumpak at maulit na resulta, kaya mainam ito para sa kontrol sa kalidad ng mga pasilidad sa pagpapalambot ng tubig at mga pasilidad sa paghahalo ng tubig. Nag-aalok din ang analyzer ng mga programmable na agwat ng oras para sa pagsusuri, oras ng pag-flush, at mga opsyon sa output gaya ng potential-free relays, 4-20mA, at CAN interface para sa dagdag na kakayahang umangkop at kaginhawaan sa pagsubaybay sa kalidad ng tubig.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan\u003eAng Hardness and Alkali analyzer ay idinisenyo upang subaybayan ang kabuuang katigasan ng tubig at carbonate hardness, pati na rin ang kabuuang alkali, nang ganap na awtomatiko sa pamamagitan ng titrasyon. Ang instrumento ay may kakayahang sumukat ng kabuuang katigasan ng tubig o carbonate hardness at kabuuang alkali nang may mataas na katumpakan at pag-uulit, kaya mainam ito para sa pagtukoy ng mga antas ng katigasan, kontrol sa kalidad ng mga pasilidad sa pagpapalambot ng tubig, at pagsubaybay sa mga pasilidad sa paghahalo ng tubig. Ang online water quality analyzer na ito ay may IP65 protection grade at angkop para gamitin sa iba't ibang industriya tulad ng agrikultura, pagkain at inumin, pangangalagang pangkalusugan, parmasyutiko, at marami pa, na ginagawa itong perpektong pagpipilian para sa mga negosyong naghahanap ng maaasahang pagsukat at pagsubaybay sa kalidad ng tubig.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eTumpak at Maaasahang Pagsukat\u003cbr\u003e\u003c\/strong\u003eAng Online Water Total Hardness Analyzer ay nag-aalok ng tumpak at maaasahang pagsukat ng kabuuang katigasan sa tubig, na tinitiyak ang tamang data para sa epektibong paggamot ng tubig.\u003cbr\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003ePatuloy na Pagsubaybay at Awtomatikong Pagsasaayos\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eGamit ang makabagong teknolohiya nito, ang Total Hardness Meter na ito ay nagbibigay-daan sa patuloy na pagsubaybay at awtomatikong pagsasaayos, na ginagarantiyahan ang pinakamainam na kalidad ng tubig sa lahat ng oras.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eTumpak at Real-Time na Data\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eAng Total Hardness Transmitter ay nagbibigay ng tumpak at real-time na data, na nagbibigay-daan para sa mabilis at may kaalamang pagpapasya sa mga proseso ng paggamot ng tubig.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eWalang-putol na Integrasyon sa mga Umiiral na Sistema\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eAng Total Hardness Transmitter ay nagbibigay-daan sa maayos na integrasyon sa mga umiiral na sistema ng paggamot ng tubig, na ginagawa itong mahalagang asset para sa anumang pasilidad na naglalayong mapabuti ang kalidad ng tubig.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"unit-wSeat8IifqaSdy5\" class=\"ce-color-dark\" type=\"text\"\u003e\n\n\u003cdiv class=\"ce-text_item\"\u003e\n\n\u003cdiv class=\"ce-text\"\u003e\n\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\n\u003cdiv class=\"ce-list_text\"\u003e\n\n\u003cdiv class=\"ce-list_summary\"\u003e\n\n\u003cdiv class=\"ce-summary\"\u003e\n\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\n\u003cdiv class=\"ce-list_image\"\u003e\n\n\u003cdiv class=\"ce-image_item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\n\u003cdiv class=\"ce-list_text\"\u003e\n\n\u003cdiv class=\"ce-list_summary\"\u003e\n\n\u003cdiv class=\"ce-summary\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch4 class=\"ce-summary\"\u003eMga Detalye\u003c\/h4\u003e\n\n\u003cdiv id=\"module-jBfmb5MgcPWi0002\"\u003e\n\n\u003cdiv id=\"grid-bslQkHAZgSRr0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-qNoMZnfyrthz0000\"\u003e\n\n\u003cdiv type=\"text\" id=\"unit-P6UEJCGQ38ju0000\"\u003e\n\n\u003cdiv class=\"ce-text_item\"\u003e\n\n\u003cdiv class=\"ce-text\"\u003e\n\n\u003cdiv class=\"table-responsive\"\u003e\n\n\u003ctable class=\"table table-bordered table-hover\" style=\"width: 100%; height: 804px;\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr class=\"firstRow\" style=\"height: 19px;\"\u003e\n\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 19px;\"\u003e\u003cstrong\u003eProdukto\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 19px;\"\u003e\u003cstrong\u003eOnline Water Total Hardness Meter\u003c\/strong\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 38px;\"\u003e\n\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 38px;\"\u003e\u003cstrong\u003eParaan ng pagsukat\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 38px;\"\u003eParaan ng titrasyon\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 54px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePapasok na tubig sa pangkalahatan\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003eMalinaw, walang kulay, walang solidong partikulo, walang mga bula ng gas\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 54px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSaklaw ng pagsukat\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003eKabuuang Katigasan : 0.5-534ppm, kabuuang alkali: 5.34~401ppm\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 35px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKatumpakan\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003e+\/- 5% \u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 35px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePag-uulit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003e±2.5%\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 54px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperatura ng tubig na sinusukat\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003e5-45℃\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 54px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePresyon ng papasok na tubig\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003etinatayang 0.5 - 5 bar (max.) (Inirerekomenda ang 1 - 2 bar)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 140px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 140px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSimula ng pagsusuri\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 140px;\"\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eProgrammable na agwat ng oras (5 - 360 minuto)\u003c\/p\u003e\n\n\u003cp\u003ePanlabas na signal\u003c\/p\u003e\n\n\u003cp\u003eProgrammable na agwat ng dami\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 35px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOras ng pag-flush\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003eProgrammable na oras ng pag-flush (15 - 1800 segundo)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 124px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 124px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eResolusyon ng temp.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 124px;\"\u003e\n\n\u003cp\u003e2 x potential-free Relays (max. 250 Vac \/ Vdc; 4A (bilang potential free output NC\/NO))\u003c\/p\u003e\n\n\u003cp\u003e0\/4-20mA\u003c\/p\u003e\n\n\u003cp\u003eCAN interface\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 35px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003eKuryente\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003e90 - 260 VAC (47 - 63Hz)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 54px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePagkonsumo ng kuryente\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003e25 VA (sa operasyon), 3.5 VA (stand by)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 38px;\"\u003e\n\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 38px;\"\u003e\u003cstrong\u003eGrado ng proteksyon\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 38px;\"\u003eIP65\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 35px;\"\u003e\n\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMga sukat\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\n\u003cp\u003e\u003cspan\u003e300x300x200 mm (WxHxD)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMga Reagent sa Katigasan \u0026amp; Mga Saklaw ng Pagsukat\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"table-responsive\"\u003e\n\n\u003ctable\u003e\n\n\u003ctbody\u003e\n\n\u003ctr class=\"firstRow\"\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eUri ng reagent\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e°dH\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e°F\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003eppm CaCO3\u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003emmol\/l\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eTH5001\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e0.03-0.3\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e0.053-0.534\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003e0.534-5.340 \u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003e0.005-0.053\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eTH5003\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e0.09-0.9\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e0.160-1.602\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003e1.602-16.02\u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003e0.016-0.160\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eTH5010\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e0.3-3.0\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e0.534-5.340\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003e5.340-53.40\u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003e0.053-0.535\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eTH5030\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e0.9-9.0\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e1.602-16.02\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003e16.02-160.2\u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003e0.160-1.602\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eTH5050\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e1.5-15\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e2.67-26.7\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003e26.7-267.0\u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003e0.267-2.670\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"142\" valign=\"top\"\u003eTH5100\u003c\/td\u003e\n\n\u003ctd width=\"152\" valign=\"top\"\u003e3.0-30\u003c\/td\u003e\n\n\u003ctd width=\"174\" valign=\"top\"\u003e5.340-53.40\u003c\/td\u003e\n\n\u003ctd width=\"176\" valign=\"top\"\u003e53.40-534.0\u003c\/td\u003e\n\n\u003ctd width=\"194\" valign=\"top\"\u003e0.535-5.340\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMga Reagent sa Alkali \u0026amp; Mga Saklaw ng Pagsukat\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"table-responsive\"\u003e\n\n\u003ctable\u003e\n\n\u003ctbody\u003e\n\n\u003ctr class=\"firstRow\"\u003e\n\n\u003ctd width=\"419\" valign=\"top\"\u003eModelo ng reagents\u003c\/td\u003e\n\n\u003ctd width=\"417\" valign=\"top\"\u003eSaklaw ng pagsukat\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5010\u003c\/td\u003e\n\n\u003ctd width=\"417\" valign=\"top\"\u003e5.34~134 ppm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5015\u003c\/td\u003e\n\n\u003ctd width=\"417\" valign=\"top\"\u003e8.01~205ppm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5020\u003c\/td\u003e\n\n\u003ctd width=\"417\" valign=\"top\"\u003e10.7~267ppm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5030\u003c\/td\u003e\n\n\u003ctd width=\"417\" valign=\"top\"\u003e16.0~401ppm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47596813287648,"sku":"870013","price":8655.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-water-total-hardness-analyzer-870013-3359228.jpg?v=1753329751","url":"https:\/\/sperdirect.com\/fil\/products\/online-water-total-hardness-analyzer","provider":"Sper Scientific Direct","version":"1.0","type":"link"}