{"product_id":"ts8503-benchtop-grating-spectrophotometer","title":"TS8503 Benchtop Grating Spectrophotometer","description":"\u003ch1\u003eThe 3nh TS8503 Benchtop Grating Spectrophotometer is a high-precision color measurement solution designed for laboratories, quality control departments and production environments requiring reliable color analysis of opaque, transparent, translucent, and fluorescent materials.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eUtilizing a dual-array CMOS sensor and advanced concave grating spectroscopic technology, the TS8503 delivers exceptional repeatability, accurate spectral data, and comprehensive color analysis across a wide range of industrial applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFeaturing a 7-inch rotatable touchscreen, integrated camera positioning system, automatic aperture recognition, and simultaneous SCI\/SCE measurement, the TS8503 streamlines color measurement while minimizing operator error. Reflectance, transmittance, haze, and UV-inclusive measurements are all supported, making it an ideal instrument for plastics, paints, coatings, textiles, inks, packaging, pharmaceuticals, food, and research laboratories. Combined with 3nh's SQCX Color Management Software, the TS8503 provides powerful reporting, quality control, and color analysis capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompared to the \u003ca href=\"https:\/\/sperdirect.com\/products\/3nh-ts8510-benchtop-grating-spectrophotometer\" title=\"3nh TS8510 Benchtop Grating Spectrophotometer\" rel=\"noopener\" target=\"_blank\"\u003e3nh TS8510 Spectrophotometer\u003c\/a\u003e, the TS8503 offers the same advanced optical platform and broad measurement capabilities in a more economical configuration, making it an excellent choice for users who need professional laboratory-grade color measurement without the enhanced performance and expanded capabilities found in the flagship TS8510.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance dual-array CMOS image sensor for outstanding accuracy and repeatability\u003c\/li\u003e\n\u003cli\u003ed\/8 integrating sphere optical geometry with simultaneous SCI\/SCE measurement\u003c\/li\u003e\n\u003cli\u003eSupports reflectance, transmittance, haze, and UV-inclusive color measurement\u003c\/li\u003e\n\u003cli\u003e360–780 nm spectral range with combined full-spectrum LED and UV illumination\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of four interchangeable measurement apertures\u003c\/li\u003e\n\u003cli\u003eBuilt-in camera for precise sample positioning\u003c\/li\u003e\n\u003cli\u003e7-inch independently rotatable capacitive touchscreen\u003c\/li\u003e\n\u003cli\u003eMeasures opaque, transparent, translucent, and fluorescent samples\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature and humidity compensation\u003c\/li\u003e\n\u003cli\u003eSupports more than 40 illuminants and multiple color spaces\u003c\/li\u003e\n\u003cli\u003e32 GB onboard storage with USB and Bluetooth connectivity\u003c\/li\u003e\n\u003cli\u003eIncludes SQCX Color Management Software for reporting and quality control\u003c\/li\u003e\n\u003cli\u003eSuitable for plastics, textiles, paints, coatings, inks, printing, pharmaceuticals, food, cosmetics and research laboratories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eNote: This item ships direct from the manufacturer. Please allow an\u003cspan\u003e \u003c\/span\u003eadditional 3-5 business days for order processing and shipment on all 3nh instruments.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTS8503 Benchtop Grating Spectrophotometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 118.354%;\" height=\"1856\" border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e\n\u003cstrong\u003eTS8503 Benchtop Grating Spectrophotometer\u003c\/strong\u003e (LED Light source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\" rowspan=\"6\"\u003eOptical Geometry\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eReflect: D\/8 (diffused illumination, 8-degree viewing angle) ;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eSCI (specular component included)\/SCE (specular component excluded) ; Include UV \/ excluded UV light source ;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eTransmittance: D\/0 (diffuse illumination: 0° viewing) ;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eSCI (specular component included)\/SCE (specular component excluded) ; Include UV \/ excluded UV light source ;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eHAZE (ASTM D1003);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eStandards meet: CIE No.15, GB\/T 3978,GB 2893,GB\/T 18833, ISO7724\/1, ASTM E1164,DIN5033 Teil7,JIS Z8722 under condition C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\" rowspan=\"5\"\u003eCharacteristic\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e1. Widely applied in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e2. 7-inch independently rotatable touch screen,32G storage,camera locating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e3. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e4. Open transmission warehouse, available thickness of 54mm transmitted samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e5. Automatic temperature and humidity compensation function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eIntegrating Sphere Size\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eΦ154mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eLight Source Device\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e360nm–780nm Wavelength range, combined LED Light. Including UV, 400nm cut-off light source, 420nm Cut-off light source, 460nm Cut-off light source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eSpectrophotometric Mode\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eConcave Grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eSensor\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e256 Image Element Double Array CMOS Image Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e360~780nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eWavelength Interval\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e10nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eSemiband Width\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e5nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eMeasured Reflectance Range\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e0~200%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eReflectivity Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\" rowspan=\"7\"\u003eMeasuring Aperture\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eReflective：\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eXLAV Φ25.4mm\/Φ30mm,\u003cbr\u003eLAVΦ15mm\/Φ18mm ,\u003cbr\u003eMAVΦ8mm\/Φ10mm,\u003cbr\u003eSAVΦ4mm\/Φ6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eTransmissive:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eΦ25.4mm(Sample height and thickness: height not limited, thickness≤54mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eRemark:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e1. Automatic identification of aperture switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e2. Customized Configuration caliber and lens position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eSpecular Component\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eReflectance: SCI\u0026amp;SCE \/ Transmittance: SCI\u0026amp;SCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eColor Space\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eColor Difference Formula\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99, ΔE(Hunter), ΔE*CH, 555 Index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\" rowspan=\"6\"\u003eOther Colorimetric Index\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eWI(ASTM E313,CIE\/ISO,AATCC,Hunter,Taube,Berger Stensby)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eYI(ASTM D1925,ASTM E313),ISO brightness,R457\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eMI (Metamerism Index),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eStaining Fastness, Color Fastness, Color Strength, Opacity,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eAPHA\/Hazen\/Pt-Co Index,Gardner Index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eHaze, Transmission(ASTM D1003), Saybolt index, ASTM D1500 Color code, 8° Gloss, 555 Index, carbon(My,dM),Color density CMYK(A,T,E,M), Tint, Color density,Pharmacopoeia (China, Europe, USA) , EBC (beer Color) , ICUMSA Color (sugar Color)(part function achieved via software in PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eObserver Angle\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e2°\/10°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\" rowspan=\"2\"\u003eIlluminant\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total,part achieved via software in PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eDisplayed Data\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eSpectrogram\/Values, Samples Chromaticity Values, Color Difference Values\/Graph, PASS\/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eMeasuring Time\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e2.0s（Measure SCI \u0026amp; SCE meantime about 4s )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\" rowspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eReflectance chromaticity value:Φ25.4mm\/SCI, Standard deviation within ΔE*ab 0.018 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003espectrum reflectance \/transmission：≤0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eInter-instrument Error\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eΦ25.4mm\/SCI, Within ΔE*ab 0.24\u003cbr\u003e(Average for 12 BCRA Series II color tiles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eDimension\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eL*W*H=440x248x283mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eApprox. 13.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eAC 24V, 3A Power adapter power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eIlluminant Life Span\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e5 years, more than 3 million times measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e\u003cspan\u003e7-inch independently rotatable touch screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eData Port\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eUSB \u0026amp; Bluetooth 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eAudit Trail Feature\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eSupport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eNetwork Correction\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eSupports Netmetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eData Storage\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e32G storage, above 100000pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eLanguage\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eSimplified Chinese, Traditional Chinese, English,(Optional Customized German,Russian, French ,Spanish ,Japanese, Thai, Korean, Polish, Portuguese)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eOperating Environment\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e0~40℃（32~104°F）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eStorage Environment\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003e-20~50℃（-4~122°F）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eStandard Accessory\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003ePower Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eOptional Accessory\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eMicro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.4752%;\"\u003eNotes\u003c\/td\u003e\n\u003ctd style=\"width: 83.6147%;\"\u003eTest reports can be printed through a network printer connected to a PC or display pad,\u003cbr\u003eThe specifications are subject to change without notice.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan class=\"s1\"\u003eDownloads\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/3nh_TS8503_Datasheet.pdf\" title=\"3nh TS8503 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e \u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/3nh_TS8503_Datasheet.pdf\" title=\"3nh TS8503 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e3nh TS8503 Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/TS8500_Benchtop_spectrophotometer_Operation_Manual_EN.doc\" title=\"3nh TS8503 Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e \u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"3nh TS8503 Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/TS8500_Benchtop_spectrophotometer_Operation_Manual_EN.doc\" target=\"_blank\"\u003e3nh TS8503 Users Manual\u003c\/a\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eComparison Chart\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComparison of TS8503 and TS8510 Benchtop Grating Spectrophotometers\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 99.9392%; height: 274.41px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003cth style=\"text-align: left; width: 36.1306%; height: 19.6007px;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"text-align: left; width: 29.0496%; height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/ts8503-benchtop-grating-spectrophotometer\" title=\"3nh TS8503 Benchtop Spectrophotometer\"\u003eTS8503\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left; width: 31.8215%; height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/3nh-ts8510-benchtop-grating-spectrophotometer\" title=\"3nh TS8510\"\u003eTS8510\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 39.2014px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 39.2014px;\"\u003e7-inch rotating touchscreen\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 39.2014px;\"\u003e10.5-inch rotating touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eInternal Storage\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003e32 GB\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003e128 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eRepeatability (ΔE*ab)\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003e≤0.02\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003e≤0.015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eInter-Instrument Agreement\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003e≤0.15 ΔE*ab\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003e≤0.15 ΔE*ab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eOptical Geometry\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003ed\/8 SCI\/SCE\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003ed\/8 SCI\/SCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eSensor\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003eDual-array CMOS\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003eDual-array CMOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003e360–780 nm\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003e360–780 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eUV Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eCamera Positioning\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 19.6007px;\"\u003eAutomatic Apertures\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 19.6007px;\"\u003eFour\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 19.6007px;\"\u003eFour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 36.1306%; height: 39.2014px;\"\u003eReflectance \/ Transmittance \/ Haze\u003c\/td\u003e\n\u003ctd style=\"width: 29.0496%; height: 39.2014px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 31.8215%; height: 39.2014px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eKnowledge Base\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eSper Knowledge Base \u0026gt; \u003ca rel=\"noopener\" title=\"Color Management\" href=\"https:\/\/sperdirect.com\/blogs\/news\/tagged\/color-management\" target=\"_blank\"\u003eColor \u003c\/a\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" title=\"Color Management\" href=\"https:\/\/sperdirect.com\/blogs\/news\/tagged\/color-management\" target=\"_blank\"\u003eManagement\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/blogs\/news\/navigating-the-spectrum-a-comprehensive-guide-to-choosing-the-right-spectrophotometer-for-your-needs\" target=\"_blank\"\u003eNavigating the Spectrum: A Guide to Choosing the Right Spectrophotometer for Your Needs\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/blogs\/news\/colorimeters-vs-spectrophotometers-which-is-the-best-tool-for-measuring-color-consistency\" target=\"_blank\"\u003eColorimeters vs. Spectrophotometers: Which is the Best Tool for Measuring Color Consistency?\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/blogs\/news\/the-importance-of-color-measurement-in-quality-control\"\u003eThe Importance of Color Measurement in Quality Control\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/sperdirect.com\/blogs\/news\/selecting-the-perfect-aperture\" title=\"Selecting the Perfect Aperture\" style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eSelecting the Perfect Aperture\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"3nh","offers":[{"title":"Default Title","offer_id":53483151818976,"sku":"TS8503","price":8427.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/ts8503-benchtop-grating-spectrophotometer-ts8503-5375988.jpg?v=1784636291","url":"https:\/\/sperdirect.com\/en-ca\/products\/ts8503-benchtop-grating-spectrophotometer","provider":"Sper Scientific Direct","version":"1.0","type":"link"}