{"product_id":"3nh-yl4560-benchtop-grating-spectrophotometer","title":"YL4560 Non-Contact Benchtop Spectrophotometer","description":"\u003ch1\u003eThe 3nh YL4560 Non-Contact Benchtop Spectrophotometer is a cutting-edge tool designed for precise and efficient color measurement and analysis.\u003c\/h1\u003e\n\u003cp\u003eThis advanced instrument is perfect for a variety of industries ranging from automotive, food and cosmetics to textiles, paints and plastics, aiming to ensure the highest standards of color quality and consistency. With its innovative features and user-friendly design, the YL4560 is an indispensable asset for professionals who require accurate color analysis without the complications of direct sample contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Measurement:\u003c\/strong\u003e Utilizes state-of-the-art technology to measure colors without physical contact, making it ideal for delicate, wet, or uneven samples, thus preserving the integrity of both the sample and the results.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Optical System:\u003c\/strong\u003e Features both d\/8° and diffuse\/8° geometry, catering to diverse needs from color matching to quality control, ensuring comprehensive color analysis.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Camera:\u003c\/strong\u003e Simplifies sample positioning with its advanced imaging capabilities, allowing for precise targeting of measurement areas, especially on complex patterns or detailed surfaces.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntuitive User Interface:\u003c\/strong\u003e Offers a user-friendly experience with easy navigation and powerful analysis tools, enabling users to efficiently set up measurements and analyze data.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Connectivity Options:\u003c\/strong\u003e Supports USB and Wi-Fi connections, facilitating seamless integration into existing workflows and easy data management for a streamlined process.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe YL4560 stands out for its precision, versatility and ease of use. It is engineered to deliver detailed insights into color characteristics, including gloss and texture, crucial for a comprehensive evaluation. Whether it's for research and development, quality control, or color matching, the 3nh YL4560 Non-Contact Benchtop Spectrophotometer is your solution for achieving flawless color accuracy and consistency across various applications.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\" data-mce-style=\"color: #ff2a00;\"\u003eNote: This item ships direct from the manufacturer. Please allow an\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eadditional 3-5 business days for order processing and shipment on all 3nh instruments.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e\u003cstrong\u003eYL4560\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eOptical Geometry\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e45\/0 method (45 ring-shaped illumination, vertical viewing); Conforms to CIE No.15,GB\/T 3978,GB 2893, GB\/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7, GB 2893,GB\/T 18833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eFeatures\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e45\/0 non-contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R \u0026amp; D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, paint and ink, printing, ceramics and other industries, and also for fluorescence sample measurement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eFull spectrum LED light,UV light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eSpectrophotometric Mode\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eConcave Grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eSensor\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e256 Image Element Double Array CMOS Image Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e400~700nm\/10nm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eReflectance Range\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e0~200%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eMeasuring Aperture\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eΦ20mm(can be customized \u0026lt;20mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eNon-contact Distance\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e7.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eSample Height\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e0~150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eDistance Adjustment Method\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eManual adjustment and automatic adjustment (test height can be stored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eMeasuring mode\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eSample mode\/QC Mode\/Continuous statistics mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eLocating Method\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eCamera Locating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eColor Space\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eCIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eColor Difference Formula\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eOther Colorimetric Index\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eWI (ASTM E313,CIE\/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),TI(ASTM E313,CIE\/ISO), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eObserver Angle\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e2°\/10°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eIlluminant\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83\/U30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eDisplayed Data\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eSpectrogram\/Values, Samples Chromaticity Values, Color Difference Values\/Graph, Chromaticity Graph, Color Simulation, PASS\/FAIL Result, Color Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eMeasuring Time\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eAbout 1.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eData Storage\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eSample mode + QC mode: 40,000; \u003cbr\u003eContinuous statistics mode: 10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003e \u003cbr\u003eRepeatability\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e \u003cbr\u003eSpectral reflectance: Standard deviation within 0.08% \u003cbr\u003eChromaticity value: Within ΔE*ab 0.03 (when a white calibration plate is measured 30 times at 5 second intervals after white calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eInter-instrument Error\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eWithin ΔE*ab 0.2（Average for 12 BCRA Series II color tiles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eMeasurement Mode\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eSingle Measurement, Average Measurement(2 ~ 99 times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eDimension\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e330*250*370mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eAbout 10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eDC 24V, 3A Power Adapter \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eIlluminant Life Span\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e5 years, more than 3 million times measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eDisplay Screen\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e7\" TFT Capacitive Screen-touch Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eData Port\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eUSB\/RS-232,Bluetooth®4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eLanguage\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eSimplified Chinese,Traditional Chinese,English\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eWorking Environment\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eTemperature: 0~40℃; Humidity: 0~85% (No Condensation); Altitude \u0026lt; 2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eStorage Environment\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003eTemperature: -20~50℃; Humidity: 0~85% (No Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eStandard Accessory\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003ePower Adapter, User Manual, USB cable, Standard Calibration Board, Black Calibration Cavity,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 129.414px;\" data-mce-style=\"width: 129.414px;\"\u003eNotes\u003c\/td\u003e\n\u003ctd style=\"width: 641.273px;\" data-mce-style=\"width: 641.273px;\"\u003e\n\u003cp\u003eThe specifications are subject to change without notice.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003eDownloads\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/YL4560.pdf\" title=\"YL4560 Non-Contact Benchtop Spectrophotometer\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" data-mce-style=\"float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/YL4560.pdf\" title=\"YL4560 Spectrophotometer\" rel=\"noopener\" target=\"_blank\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"YL4560 Spectrophotometer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/YL4560_Spectrophotometer.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" data-mce-style=\"float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"YL4560_Spectrophotometer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/YL4560_Spectrophotometer.pdf\" target=\"_blank\"\u003eUsers Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003eKnowledge Base\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eSper Knowledge Base \u0026gt; \u003ca rel=\"noopener\" title=\"Color Management\" href=\"https:\/\/sperdirect.com\/blogs\/news\/tagged\/color-management\" target=\"_blank\"\u003eColor \u003c\/a\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" title=\"Color Management\" href=\"https:\/\/sperdirect.com\/blogs\/news\/tagged\/color-management\" target=\"_blank\"\u003eManagement\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/blogs\/news\/navigating-the-spectrum-a-comprehensive-guide-to-choosing-the-right-spectrophotometer-for-your-needs\" data-mce-href=\"https:\/\/sperdirect.com\/blogs\/news\/navigating-the-spectrum-a-comprehensive-guide-to-choosing-the-right-spectrophotometer-for-your-needs\" target=\"_blank\"\u003eNavigating the Spectrum: A Guide to Choosing the Right Spectrophotometer for Your Needs\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/blogs\/news\/colorimeters-vs-spectrophotometers-which-is-the-best-tool-for-measuring-color-consistency\" data-mce-href=\"https:\/\/sperdirect.com\/blogs\/news\/colorimeters-vs-spectrophotometers-which-is-the-best-tool-for-measuring-color-consistency\" target=\"_blank\"\u003eColorimeters vs. Spectrophotometers: Which is the Best Tool for Measuring Color Consistency?\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/blogs\/news\/the-importance-of-color-measurement-in-quality-control\" data-mce-href=\"https:\/\/sperdirect.com\/blogs\/news\/the-importance-of-color-measurement-in-quality-control\"\u003eThe Importance of Color Measurement in Quality Control\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/sperdirect.com\/blogs\/news\/selecting-the-perfect-aperture\" title=\"Selecting the Perfect Aperture\" style=\"font-size: 0.875rem;\" data-mce-href=\"https:\/\/sperdirect.com\/blogs\/news\/selecting-the-perfect-aperture\"\u003e\u003cstrong\u003eSelecting the Perfect Aperture\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"3nh","offers":[{"title":"Default Title","offer_id":44939212128480,"sku":"YL4560","price":11168.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/products\/yl4560-non-contact-benchtop-spectrophotometer-yl4560-295659.jpg?v=1752691891","url":"https:\/\/sperdirect.com\/en-ca\/products\/3nh-yl4560-benchtop-grating-spectrophotometer","provider":"Sper Scientific Direct","version":"1.0","type":"link"}