{"product_id":"industrial-online-phosphate-analyzer-870019","title":"Online Industrial Phosphate Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870019 Industrial Online Phosphate Analyzer continuously monitors phosphate concentration in process water using photoelectric colorimetry.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIt supports water chemistry monitoring in power plants and chemical processing facilities.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe color LCD displays current readings and trend curves, with approximately one month of historical data available for review. A 4–20 mA output and RS485 communication connect the analyzer to monitoring equipment. Automatic calibration and optional multi-channel configurations support routine monitoring of one or more sample streams.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated phosphate measurement with optical detection\u003c\/li\u003e\n\u003cli\u003eColor display with real-time trend curves\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration\u003c\/li\u003e\n\u003cli\u003eOne to six sample channels available by configuration\u003c\/li\u003e\n\u003cli\u003eAudible and relay alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870019\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMethod\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eMolybdenum yellow photoelectric colorimetry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000 µg\/L or 0–10 mg\/L; select when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDrift\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±1% of full scale per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResponse\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eInitial response 4 minutes; at least 98% response in 6 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSampling period\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e3 minutes per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSample conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eFlow \u0026gt;2 mL\/s; temperature 10–45°C; pressure 10–100 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAmbient conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e5–45°C; reduced accuracy above 40°C; \u0026lt;85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eReagent\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne type; approximately 3 L per month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAlarms\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eBuzzer and normally open relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485 Modbus RTU; LAN, Wi-Fi or 4G options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%, 50 Hz; approximately 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e720 × 460 × 300 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMounting hole dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e665 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the analyzer measure?\u003c\/strong\u003e\u003cbr\u003eThe specified sampling period is 3 minutes per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it monitor multiple sample streams?\u003c\/strong\u003e\u003cbr\u003eConfigurations with one to six channels are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need reagent?\u003c\/strong\u003e\u003cbr\u003eYes. The analyzer uses one type of reagent that must be replenished.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68217987268832,"sku":"870019","price":12497.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-phosphate-analyzer-870019-5753256.jpg?v=1793360776","url":"https:\/\/sperdirect.com\/de\/products\/industrial-online-phosphate-analyzer-870019","provider":"Sper Scientific Direct","version":"1.0","type":"link"}