{"title":"Wastewater","description":"\u003cp\u003e\u003cstrong\u003eWastewater monitoring instruments help operators evaluate water quality, manage treatment processes and track changes in municipal and industrial effluent. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring parameters such as pH, ORP, dissolved oxygen, conductivity and turbidity supports informed decisions throughout collection, treatment and discharge.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSper Scientific offers water quality meters, online analyzers and sensors for routine testing and continuous monitoring. Select instruments based on your measurement range, wastewater conditions, installation requirements and maintenance needs to support reliable performance in demanding treatment environments.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"cod-bod-toc-sensor","title":"Online COD Sensor with BOD\/TOC Correlation","description":"\u003ch1 class=\"p1\"\u003e\n\u003cspan class=\"s1\"\u003eThe Online COD Sensor is an advanced device designed to measure the concentration of soluble organic matter in water by utilizing the absorption of ultraviolet (UV) light at 254 nm. \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/multi-parameter-inline-water-quality-analyzer-870001-820665_100x100.jpg?v=1730508960\" alt=\"Multi-Parameter Water Quality Analyzer\" style=\"margin-right: 16px; margin-bottom: 16px; float: left;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cbr\u003eThis sensor is only for use with: \u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/multi-parameter-analyzer\" title=\"Multi-parameter-analyzer\"\u003eSper Scientific 870001 \u003cspan\u003eMulti-Parameter Water Quality Analyzer\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThis UV spectral absorption coefficient (SAC254) reflects the presence of organic compounds and can be converted into a chemical oxygen demand (COD) value under specific conditions. This method allows for continuous, real-time monitoring without the need for chemical reagents, making it an eco-friendly and efficient solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003e\u003cspan class=\"s2\"\u003eWhat is BOD COD and TOC?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s1\"\u003eBOD - Biochemical Oxygen Demand\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003eCOD - Chemical Oxygen Demand\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003eTOC - Total Organic Carbon\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p6\"\u003e\u003cspan class=\"s1\"\u003eThe sensor offers a simple yet effective way to track organic pollution in various water sources, with minimal maintenance and no need for pre-processing. Its fast response time and automatic cleaning function ensure reliable, long-term performance, making it ideal for wastewater treatment facilities, industrial water discharge monitoring, and environmental water quality assessments.\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li6\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDirect immersion measurement\u003c\/b\u003e: No need for sampling or pre-processing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li6\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eReagent-free operation\u003c\/b\u003e: No chemical reagents are required, preventing secondary pollution.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li6\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFast response and continuous monitoring\u003c\/b\u003e: Real-time results for efficient process control.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li6\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eAutomatic cleaning function\u003c\/b\u003e: Low-maintenance, ensuring consistent performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li6\"\u003e\u003cspan class=\"s1\"\u003eContinuous monitoring of organic load in sewage treatment processes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li6\"\u003e\u003cspan class=\"s1\"\u003eReal-time monitoring of influent and effluent in wastewater treatment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li6\"\u003e\u003cspan class=\"s1\"\u003eSuitable for surface water, industrial discharge and fishery water quality monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Online \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"s1\"\u003eSpecifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 235.125px;\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 39.1875px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 39.1875px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003e0-200mg, 0~1000mg\/l \u003cbr\u003eCOD (2mm optical path)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003e±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Interval\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003eMinimum 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003e≤0.4Mpa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eSensor Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003eSUS316L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003e-15℃ ~ 65℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003e0℃~45℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003e70mm*395mm (Diameter*length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 19.5938px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 19.5938px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 45.4545%; height: 39.1875px;\" width=\"250\" valign=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 118.364%; height: 39.1875px;\" width=\"651\" valign=\"center\"\u003e\u003cspan\u003eStandard 10m cable, can be extended to 100 meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001-COD_User_Manual.pdf\" title=\"Inline COD\/BOD\/TOC Sensor Instruction Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001-COD_User_Manual.pdf\" title=\"Inline COD\/BOD\/TOC Sensor Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246434963680,"sku":"870001-COD","price":11747.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-codbodtoc-sensor-870001-cod-922922.webp?v=1752691896"},{"product_id":"inline-digital-ion-sensor","title":"Online Digital Ion Sensor","description":"\u003ch1\u003eThe Sper Scientific Inline Digital Ion Sensor is equipped with RS485 communication and a standard Modbus protocol, making it highly adaptable for remote monitoring.\u003c\/h1\u003e\n\u003cp\u003eIts corrosion-resistant PPS+POM housing meets IP68 standards, ensuring durability in various water quality monitoring environments. The sensor features an industrial-grade composite electrode with a double salt bridge reference design for extended lifespan. With a built-in temperature sensor and compensation algorithm, it offers high precision in measurement.\u003c\/p\u003e\n\u003cp\u003eWidely used in both domestic and international research institutions, chemical production, agricultural fertilization and organic wastewater management, this sensor is ideal for detecting general sewage, wastewater and surface water. It can be installed in sinks or flow tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable ion measurement options\u003c\/li\u003e\n\u003cli\u003eCompact design for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWastewater plants\u003c\/li\u003e\n\u003cli\u003eGroundwater monitoring\u003c\/li\u003e\n\u003cli\u003eAquaculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable cellspacing=\"0\" border=\"1\" style=\"width: 79.0191%; height: 491.102px;\" height=\"462\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 55.1875px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 55.1875px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"justify\"\u003e\u003cstrong\u003e870001-ION Digital Ion Sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.7891px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 40.7891px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eIons type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 40.7891px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eF\u003csup\u003e-\u003c\/sup\u003e,Cl\u003csup\u003e-\u003c\/sup\u003e,Ca\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e,NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e,NH\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e,K\u003csup\u003e+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e0.02-1000ppm (mg\/L)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e0.01mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 55.1875px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 55.1875px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"justify\"\u003e\u003cspan\u003e12V (customized for 5V,24VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eSlope\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e52~59mV\/25℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u0026lt;±2% 25℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u0026lt;60s (90% right value)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eStandard RS485 Modbus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature compensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003ePT1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 55.1875px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 55.1875px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"justify\"\u003e\u003cspan\u003eD:30mm, L:250mm, cable: \u003cbr\u003e3 meters (can be extended)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"292\" valign=\"top\" style=\"width: 52.8868%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eWorking environment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"715\" valign=\"top\" style=\"width: 47.1132%; height: 35.5938px;\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e0~45℃ , 0~2bar\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e \u003cb\u003eReference Ion\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"table_wrap\"\u003e\n\u003ctable style=\"width: 83.9237%; height: 328px;\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 35.5938px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eIon Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 35.5938px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eFormula\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 35.5938px;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003eInterfering ion\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 55.1875px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eFluoride ion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 55.1875px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eF\u003csup\u003e-\u003c\/sup\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 55.1875px; text-align: left;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003eOH\u003csup\u003e-\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 55.1875px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eChloride ion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 55.1875px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eCl\u003csup\u003e-\u003c\/sup\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 55.1875px; text-align: left;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003eCN\u003csup\u003e-\u003c\/sup\u003e, Br, I\u003csup\u003e-\u003c\/sup\u003e, OH\u003csup\u003e-\u003c\/sup\u003e, S\u003csup\u003e2-\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63.0469px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 63.0469px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eCalcium ion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 63.0469px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eCa\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 63.0469px; text-align: left;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003ePb\u003csup\u003e2+\u003c\/sup\u003e,Hg\u003csup\u003e2+\u003c\/sup\u003e,Si\u003csup\u003e2+\u003c\/sup\u003e,Fe\u003csup\u003e2+\u003c\/sup\u003e,Cu\u003csup\u003e2+\u003c\/sup\u003e,Ni\u003csup\u003e2+\u003c\/sup\u003e,NH\u003csub\u003e3\u003c\/sub\u003e,Na\u003csup\u003e+\u003c\/sup\u003e,\u003cbr\u003eLi\u003csup\u003e+\u003c\/sup\u003e,Tris\u003csup\u003e+\u003c\/sup\u003e,K\u003csup\u003e+\u003c\/sup\u003e,Ba\u003csup\u003e+\u003c\/sup\u003e,Zn\u003csup\u003e2+\u003c\/sup\u003e,Mg\u003csup\u003e2+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.7891px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 40.7891px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eNitrate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 40.7891px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eNO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 40.7891px; text-align: left;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003eCIO\u003csub\u003e4\u003c\/sub\u003e-,I\u003csup\u003e-\u003c\/sup\u003e,CIO\u003csub\u003e3\u003c\/sub\u003e-,F\u003csup\u003e-\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 55.1875px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eAmmonium ion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 55.1875px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eNH\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 55.1875px;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003eK\u003csup\u003e+\u003c\/sup\u003e,Na\u003csup\u003e+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38.2578px;\"\u003e\n\u003ctd style=\"width: 28.4314%; height: 38.2578px;\" width=\"177\" valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003ePotassium\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 18.6275%; height: 38.2578px;\" width=\"115\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eK\u003csup\u003e+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 52.9412%; height: 38.2578px;\" width=\"715\" valign=\"top\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003eCs\u003csup\u003e+\u003c\/sup\u003e,NH4\u003csup\u003e+\u003c\/sup\u003e,Tl\u003csup\u003e+\u003c\/sup\u003e,H\u003csup\u003e+\u003c\/sup\u003e,Ag\u003csup\u003e+\u003c\/sup\u003e,Tris\u003csup\u003e+\u003c\/sup\u003e,Li\u003csup\u003e+\u003c\/sup\u003e,Na\u003csup\u003e+\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inline_Digital_Online_Ion_Sensor_User_Manual.pdf\" title=\"Inline Digital Ion Sensor - User Manual\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inline_Digital_Online_Ion_Sensor_User_Manual.pdf\" title=\"Inline Digital Ion Sensor - User Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246434996448,"sku":"870001-ION","price":1980.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-ion-sensor-870001-ion-892030.jpg?v=1752691910"},{"product_id":"ammonia-nitrogen-sensor","title":"Online Ammonia Nitrogen Sensor","description":"\u003ch1 class=\"p1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003eThe Inline Ammonia Nitrogen Sensor is a cutting-edge digital sensor designed for precise measurement of ammonia nitrogen concentrations in various water environments.\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/multi-parameter-inline-water-quality-analyzer-870001-820665_100x100.jpg?v=1730508960\" alt=\"Multi-Parameter Water Quality Analyzer\" style=\"margin-right: 16px; margin-bottom: 16px; float: left;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cbr\u003eThis sensor is only for use with: \u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/multi-parameter-analyzer\" title=\"Multi-parameter-analyzer\"\u003eSper Scientific 870001 \u003cspan\u003eMulti-Parameter Water Quality Analyzer\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003eUtilizing advanced ion selective electrode technology, this sensor delivers reliable and accurate readings essential for effective water quality management. \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eIts advanced technology and precision sensors allow for precise and consistent readings, ensuring the quality and integrity of experimental data.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDirect Measurement: \u003c\/b\u003eThe sensor employs an ammonium ion selective electrode that directly detects ammonium ions, ensuring accurate determination of ammonia nitrogen levels.\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eStability:\u003c\/b\u003e A pH electrode serves as a reference, enhancing the stability of measurements and ensuring consistent performance.\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eInterference Compensation:\u003c\/b\u003e The sensor includes potassium ion compensation to mitigate interference from potassiu\u003c\/span\u003e\u003cspan class=\"s1\"\u003em ions, providing more reliable readings in varying water conditions.\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIntegrated Design:\u003c\/b\u003e This comprehensive sensor probe integrates an ammonium ion selective electrode, an optional potassium ion electrode, a pH electrode, and a temperature electrode, allowing for multi-parameter measurements.\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eAdvanced Technology\u003c\/b\u003e: Its advanced sensors allow for precise and consistent readings, ensuring the quality and integrity of experimental data.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eVersatile Applications: \u003c\/b\u003eIdeal for use in sewage treatment plants, nitrification processes, aeration tanks and industrial water systems, as well as in scientific research and river water.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\"\u003eSpecifications\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 720pt; height: 528.376px;\" width=\"960\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 8618; width: 202pt;\" width=\"269\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 22101; width: 518pt;\" width=\"691\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px; width: 202pt;\" width=\"269\" class=\"xl64\" height=\"24\"\u003e\n\u003cp\u003eProduct\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 518pt; box-sizing: border-box; height: 26.6641px;\" width=\"691\" class=\"xl64\"\u003eInline Digital Ammonia Nitrogen Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 79.8829px; box-sizing: border-box;\" class=\"xl64\" height=\"72\" rowspan=\"3\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003eNH4N：0.1-1000 mg\/L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003eK+：0.5-1000 mg\/L （Optional）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003epH：5-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 106.547px; box-sizing: border-box;\" class=\"xl64\" height=\"96\" rowspan=\"4\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003eNH4N：±5 % of the measured value or ± 0.2 mg\/L, take the greater one.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003eK+：±5 % of the measured value or ±0.2 mg\/L Optional）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003eTemperature：±0.1C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003epH：±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003e0-45 ℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 106.547px; box-sizing: border-box;\" class=\"xl64\" height=\"96\" rowspan=\"4\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003eNH4N：0.01 mg\/l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003eK+：0.01 mg\/l（Optional）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003eTemperature：0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.6641px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.6641px;\" class=\"xl65\" height=\"24\"\u003epH：0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eSize\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003e2.17\" x 13.39\" (55mm x 340mm)（Diameter x Length）\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003e4-20mA load \u0026lt;750Ω (optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eDC12V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.5547px; box-sizing: border-box;\" height=\"24\"\u003e\n\u003ctd style=\"height: 26.5547px; box-sizing: border-box;\" class=\"xl64\" height=\"24\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; height: 26.5547px;\" class=\"xl65\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eStandard cable 10M, can be extended up to 100M\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPER_870001-NH_Inline_Ammonia_Nitrogen_Sensor_User_Manual.pdf\" title=\"Inline Ammonia Nitrogen Sensor Instruction Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPER_870001-NH_Inline_Ammonia_Nitrogen_Sensor_User_Manual.pdf\" title=\"Inline Ammonia Nitrogen Senso Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435029216,"sku":"870001-NH","price":6423.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-ammonia-nitrogen-sensor-870001-nh-365308.webp?v=1752691909"},{"product_id":"inline-digital-nitrate-nitrogen-sensor","title":"Online Digital Nitrate Nitrogen Sensor","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"12cbd555-acd5-4218-981d-b8963ee09243\" dir=\"auto\" class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+\u0026amp;]:mt-5\" data-message-model-slug=\"gpt-4o\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003ch1\u003eThis spectrometer-based Sensor measures Nitrate Nitrogen (NO3-N) directly via its absorption of 210 nm UV light.\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-right: 16px; margin-bottom: 16px; float: left;\" alt=\"Multi-Parameter Water Quality Analyzer\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/multi-parameter-inline-water-quality-analyzer-870001-820665_100x100.jpg?v=1730508960\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cbr\u003eThis sensor is only for use with: \u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003ca title=\"Multi-parameter-analyzer\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/multi-parameter-analyzer\"\u003eSper Scientific 870001 \u003cspan\u003eMulti-Parameter Water Quality Analyzer\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAs water flows through the sensor slit, a portion of the light is absorbed by the sample, while the remaining light passes through, reaching the opposite side of the sensor. This absorption is used to calculate nitrate concentration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Measurement\u003c\/strong\u003e: Measures nitrate nitrogen directly from the sample without the need for pre-processing or sampling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-Friendly Operation\u003c\/strong\u003e: Requires no chemical reagents, eliminating secondary pollution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast, Continuous Monitoring\u003c\/strong\u003e: Provides a rapid response time with real-time, continuous online measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Maintenance\u003c\/strong\u003e: Features an automatic cleaning function to reduce maintenance demands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Protection\u003c\/strong\u003e: Includes positive and negative reverse connection protection for reliable power supply use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS485 Terminal Safety\u003c\/strong\u003e: Power supply protection for RS485 A\/B terminals for secure connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrinking and Surface Water\u003c\/strong\u003e: Ideal for nitrate monitoring in drinking water sources and natural water bodies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Water and Wastewater\u003c\/strong\u003e: Suitable for industrial process water and wastewater treatment applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNitrate Monitoring\u003c\/strong\u003e: Designed for continuous monitoring of nitrate concentration in water, especially beneficial for managing sewage aeration tanks and denitrification processes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv class=\"table_wrap\"\u003e\n\u003ctable style=\"width: 100%; height: 266px;\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eNitrate Nitrogen NO3-N: 0.1~40.0mg\/L\u003c\/strong\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e±5%\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e± 2% \u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e0.01 mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e≤0.4Mpa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 38px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eSensor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 38px;\" width=\"854\" valign=\"center\"\u003e\n\u003cspan\u003eBody: SUS316L (freshwater), \u003c\/span\u003e\u003cspan\u003eTitanium Alloy (Ocean marine); \u003c\/span\u003e\u003cspan\u003eCable: PUR\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003eStandard calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e12VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003eMODBUS RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e0-45℃ (Non-freezing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003e2.7x15 inches (69mmx380mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003eIP68\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 44.283122%; height: 19px;\" width=\"244\" valign=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 154.990926%; height: 19px;\" width=\"854\" valign=\"center\"\u003e\u003cspan\u003eStandard 10M, can be extended to 100m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Nitrate Nitrogen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Nitrate_Nitrogen_Sensor_Users_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Nitrate Nitrogen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Nitrate_Nitrogen_Sensor_Users_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435061984,"sku":"870001-NO3","price":11337.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-nitrate-nitrogen-sensor-870001-no3-486122.jpg?v=1752691898"},{"product_id":"ultrasonic-level-meter","title":"Integrated Ultrasonic Level Meter","description":"\u003ch1\u003eThe Ultrasonic Level Meter combines the strengths of various level measurement instruments into a fully digital and user-friendly system.\u003c\/h1\u003e\n\u003cp\u003eIt offers reliable level monitoring, seamless data transmission, and intuitive human-machine interaction. With robust anti-interference capabilities, customizable upper and lower limits, and online output adjustments, it supports on-site display and multiple output options, including analog, switching and RS485 for easy integration with control systems. \u003c\/p\u003e\n\u003cp\u003eConstructed with a waterproof engineering plastic cover and ABS probe, it suits diverse level measurement applications. Additional modules like RS485 and current output can be added for enhanced compatibility with PLCs. Key features include wide DC12-24V voltage range, parameter backup and recovery, flexible analog output adjustment, filter settings to eliminate noise, customizable serial data formats, and adjustable pulse intensity for measuring air gaps or liquid levels.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eDC12-24V wide work voltage\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eBackup and recovery parameter set\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFree adjustment of the range of analog output\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eSet a filter value to remove\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eCustom serial port data format\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eMeasure measure air space or liquid level\u003c\/li\u003e\n\u003cli class=\"p1\"\u003e1-15 transmitted pulse intensity depending on working conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 654pt; box-sizing: border-box; outline: 0px; border-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; height: 301px;\" width=\"872\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 296px;\" width=\"296\"\u003e \u003ccol style=\"width: 575px;\" width=\"576\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; width: 222pt; box-sizing: border-box; outline: 0px;\" width=\"296\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 432pt; box-sizing: border-box; outline: 0px; height: 24px;\" width=\"576\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e5, 8, 10, 12, 15m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13px;\"\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e±0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eBlind Zone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e＜\u003cspan class=\"font5\"\u003e0.3-0.5m (different for range)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDisplay resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e1mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e20~350KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e12-24VDC; consumption:\u0026lt;1.5W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e4~20mA RL\u0026gt;600\u003cspan class=\"font6\"\u003eΩ\u003c\/span\u003e\u003cspan class=\"font5\"\u003e(standard),1~5V\\1~10V\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e2 NPN relays (AC: 5A 250V DC: 10A 24V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eΦ\u003cspan class=\"font5\"\u003e92mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003e198mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003eM60\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eIP65 (others optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eElectrical interface: M20X1.5, Installation: M60X2 or ￠61MM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435094752,"sku":"870010","price":568.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/integrated-ultrasonic-level-meter-870010-7414059.jpg?v=1760646507"},{"product_id":"inline-industrial-conductivity-electrode","title":"Online Industrial Conductivity Electrode","description":"\u003ch1\u003eThe Industrial Conductivity Series electrodes are purpose-built for precise conductivity measurements in pure water, ultra-pure water and water treatment applications.\u003c\/h1\u003e\n\u003cp\u003eThese electrodes are especially suitable for use in thermal power plants and the water treatment industry, where durability and accuracy are critical. Featuring a robust double-cylinder structure made from titanium alloy, they naturally oxidize to form a chemically passive layer, enhancing resistance to various liquids (excluding hydrofluoric acid). Temperature compensation components are available in multiple options, including NTC2.252K, 2K, 10K, 20K, 30K, PT100, and PT1000, which can be specified based on user needs.\u003c\/p\u003e\n\u003cp\u003eThe K=10.0 or K=30 electrodes in this series incorporate a large-area platinum structure, providing excellent resistance to strong acids and alkalis as well as high anti-fouling capacity. These electrodes are well-suited for on-line conductivity measurement in demanding industries such as wastewater treatment and seawater purification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-cylinder structure with corrosion-resistant titanium alloy\u003c\/li\u003e\n\u003cli\u003eNaturally oxidized, chemically passive surface for improved durability\u003c\/li\u003e\n\u003cli\u003eMultiple temperature compensation options: NTC2.252K, 2K, 10K, 20K, 30K, PT100, PT1000\u003c\/li\u003e\n\u003cli\u003eLarge-area platinum structure on K=10.0 and K=30 models for resistance to strong acids and alkalis\u003c\/li\u003e\n\u003cli\u003eExcellent anti-fouling capacity, ideal for specialized industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable border=\"0\" style=\"width: 100%; height: 430px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConstant of electrode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"6\" style=\"width: 46.058303%; height: 430px;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.boquinstruments.com\/uploads\/DDG-0.1-Industrial-Conductivity-Sensor.jpg\" alt=\"DDG-0.1 Industrial Conductivity Sensor\" class=\"alignnone size-full wp-image-2585\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eCompressive strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.6 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 19px;\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 19px;\"\u003e\u003cspan\u003e0-2000 uS\/em\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e1\/2 or 3\/4 Thread Installation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\n\u003cspan\u003e316L Titanium Alloy \u003cbr\u003eand \u003c\/span\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 259px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 259px;\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 259px;\"\u003e\u003cspan\u003eWater Treatment Industry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"870003-ICE-01","offer_id":52569194791136,"sku":"870003-ICE-01","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-02","offer_id":52569194823904,"sku":"870003-ICE-02","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-03","offer_id":52569194856672,"sku":"870003-ICE-03","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-04","offer_id":52569194889440,"sku":"870003-ICE-04","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-05","offer_id":52569194922208,"sku":"870003-ICE-05","price":170.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-conductivity-electrode-870003-ice-994131.jpg?v=1752691912"},{"product_id":"industrial-conductivity-tds-salinity-resistivity-meter","title":"Online Industrial Conductivity, TDS, Salinity, Resistivity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Industrial Conductivity, TDS, Salinity and Resistance Meter is essential for inline monitoring of water conductivity in applications like drinking water treatment, industrial water and boiler water.\u003c\/h1\u003e\n\u003cp\u003eConductivity measurements provide valuable insight into the amount of dissolved material in water. We offer a wide range of high-quality, affordable conductivity sensors, suitable for everything from deionized water to highly saturated brines. \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eWhy is conductivity measurement important in water treatment? The conductivity of water is crucial because it gives an indication of the amount of dissolved material within that water. \u003cmeta charset=\"utf-8\"\u003ePaired with Sper Scientific conductivity controllers, this meter delivers reliable, cost-effective process control across industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-functional: Measures conductivity, TDS, resistivity, salinity, and temperature\u003c\/li\u003e\n\u003cli\u003eReliable conductivity monitoring for consistent results\u003c\/li\u003e\n\u003cli\u003eEasy system integration for seamless conductivity measurement\u003c\/li\u003e\n\u003cli\u003eIdeal for all water quality environments\u003c\/li\u003e\n\u003cli\u003eCompatible with contact conductivity sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\" style=\"width: 70.766488%;\" height=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInline Conductivity Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eConductivity, TDS, Resistivity, Salinity, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e0.00uS\/cm~2000000.00 uS\/cm(0.00uS\/cm~2000.00 mS\/cm)\u003c\/p\u003e\n\u003cp\u003e0.00g\/L~80.00 g\/L (ppt)\u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~130000.00 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003e0.00MΩ~20.00MΩ\u003c\/p\u003e\n\u003cp\u003e-40.0℃~200.0℃ (refer to matching electrode)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays: 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%; text-align: left;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435225824,"sku":"870003","price":722.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/industrial-conductivity-tds-salinity-resistivity-meter-870003-600932.jpg?v=1752691869"},{"product_id":"industrial-inductive-acid-alkaline-sensor","title":"Online Inductive Acid-Alkaline Concentration Sensor","description":"\u003ch1 class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThis digital conductivity sensor is equipped to measure and digitize conductivity, various salinity levels and concentrations of acids and alkalis. \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eWith an integrated signal processing circuit and embedded MCU ASIC, this conductivity sensor overcomes previous sensor limitations. It is factory-calibrated, with the calibration values stored permanently within the probe, ensuring reliable performance over time. The sensor also includes a temperature compensation feature with direct digital output of temperature data.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eChemical and Wastewater \u003cmeta charset=\"utf-8\"\u003eFacilities, River Water, Power Plants\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModels:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e870009-CS: Standard polypropylene (PEEK) sensor (rated to 176º F \/ 80º C)\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003e870009-CS2: Mid-range \u003cspan\u003epolypropylene (PEEK) sensor (rated to 302º F \/ 150º C)\u003c\/span\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e870009-CS-PFA: Hi-Temp sensor with PFA coating\u003cspan\u003e (rated to 176º F \/ 80º C)\u003cbr\u003e870009-CS2-PFA  Hi-Temp sensorwith PFA coating (rated to 257º F \/ 125º C)\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003eExceptional performance in harsh chemical environments, with chemical-resistant materials that resist polarization and prevent grime buildup, making it suitable for high-acid environments like fuming sulfuric acid. Simple, wide-ranging installation options for versatile applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003eHigh accuracy and stability, specifically designed for English acid concentration measurement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003eAdvanced conductivity sensor technology eliminates clogging and polarization errors, ensuring reliable operation in environments prone to electrode blockage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003eLarge aperture sensor design for long-term stability and robust performance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003eCompatible with various mounting brackets and bulkhead structures, allowing flexible installation across applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan class=\"s1\"\u003eSpecifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e870009-CS-PFA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e870009-CS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e870009-CS2-PFA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e870009-CS2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eElectrode body material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"293\" nowrap colspan=\"2\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-20~80\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~125\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~150\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1mS\/cm ~ 2000mS\/cm\u003cbr\u003eHNO3: 0.00%~29.00%\/35.00%~96.00%(25C)\u003cbr\u003eH2SO4: 0.00%~29.00%\/30.00%~83.00%\/93.00%~99.00%(10°C)\u003cbr\u003eHCL: 0.00%~18.00%\/22.00%~39.00%(25°C) \u003cbr\u003eNaOH: :0.00%~14.00%\/18.00%~50.00%(25°C)\u003cbr\u003eNaCl:0.00%~26.00%(20°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e±2% of reading or  ± 1 mS\/cm, whichever is greater;  ±0.5\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMaximum pressure (bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOutput\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eModbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Inductive_Conductivity_Sensor_Datasheet.pdf\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Inductive_Conductivity_Sensor_Datasheet.pdf\"\u003e870009 Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009-CS2-Inductive-Conductivity-Sensor-User-Manual.pdf?v=1788197630\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009-CS2-Inductive-Conductivity-Sensor-User-Manual.pdf\"\u003e870009 Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"870009-CS (rated to 176º F \/ 80º C)","offer_id":47008857555168,"sku":"870009-CS","price":1821.75,"currency_code":"USD","in_stock":true},{"title":"870009-CS2 (rated to 302º F \/ 150º C)","offer_id":47009050231008,"sku":"870009-CS2","price":1903.65,"currency_code":"USD","in_stock":true},{"title":"870009-CS-PFA (rated to 176º F \/ 80º C)","offer_id":47008857587936,"sku":"870009-CS-PFA","price":1882.65,"currency_code":"USD","in_stock":true},{"title":"870009-CS2-PFA (rated to 257º F \/ 125º C)","offer_id":54581983805664,"sku":"870009-CS2-PFA","price":1841.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-inductive-acid-alkaline-concentration-sensor-870009-cs-1260198.jpg?v=1788270247"},{"product_id":"industrial-dissolved-oxygen-meter","title":"Online Industrial Dissolved Oxygen Meter","description":"\u003ch1\u003eInline Dissolved Oxygen Analyzer is designed for continuous, real-time DO monitoring across a wide range of industrial processes.\u003c\/h1\u003e\n\u003cp\u003eBuilt with a rugged yet straightforward design, the industrial dissolved oxygen probes deliver precise measurements in any process condition. Ideal for industries like pharmaceuticals, food and beverage, chemicals, power, microelectronics and clean water applications, this system ensures reliable dissolved oxygen monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient and easy-to-service dissolved oxygen measurement\u003c\/li\u003e\n\u003cli\u003eMeasures dissolved oxygen levels from ppb to ppm\u003c\/li\u003e\n\u003cli\u003eFast response time, even at ppb levels\u003c\/li\u003e\n\u003cli\u003eDurable, hygienic design for continuous online monitoring\u003c\/li\u003e\n\u003cli\u003eUser-friendly operation with an intuitive interface\u003c\/li\u003e\n\u003cli\u003eLower overall cost per measurement point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper #870007 Dissolved Oxygen Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"272\" colspan=\"2\" rowspan=\"1\"\u003e\u003cspan\u003eDissolved Oxygen, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDO Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\" width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\n\u003cp\u003e0.00~20.00 ug\/L \u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~20.00 mg\/L \u003c\/p\u003e\n\u003cp\u003e0.00%~200.00 % \u003c\/p\u003e\n\u003cp\u003e-10.0℃~130.0℃ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" colspan=\"1\" rowspan=\"1\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant: V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" rowspan=\"1\" colspan=\"1\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays, 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K \/ 22K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"79\" rowspan=\"1\" colspan=\"1\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"79\" rowspan=\"1\" colspan=\"1\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870007_Industrial_DO_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870007_Industrial_DO_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435455200,"sku":"870007","price":825.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-optical-dissolved-oxygen-meter-870006-203770.jpg?v=1752691908"},{"product_id":"digital-optical-dissolved-oxygen-meter","title":"Online Digital Optical Dissolved Oxygen Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eSper Scientific Inline Digital Optical Dissolved Oxygen Meter features an advanced sensor designed for precise, real-time measurement of dissolved oxygen and temperature in a variety of applications. \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eEngineered for durability and minimal maintenance, this meter is ideal for harsh environments. This Digital Optical Dissolved Oxygen Meter is an essential tool for ensuring optimal water quality and effective monitoring across various industries, enhancing operational efficiency and compliance with environmental standards. \u003c\/span\u003e\u003cspan class=\"s1\"\u003eEngineered for durability and maintenance-free operation, it features innovative light source technology that ensures a long service life while reducing operational costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThis meter offers dual 4-20mA output options for seamless integration into existing systems, providing real-time data for both dissolved oxygen and temperature. With a built-in data recording function, users can easily access historical data and trends for effective monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eDesigned for versatile installation, the meter can be panel-mounted, wall-mounted, or pipe-mounted. It incorporates RS485 Modbus RTU communication for straightforward digital integration. Additionally, the device includes three relay outputs: two for high and low limit alarms and one for clean time settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eIdeal for applications in industrial wastewater, drinking water, pulp and paper processing and the chemical industry, this optical dissolved oxygen meter ensures optimal water quality and compliance across various treatment processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003eDissolved oxygen (DO) is the oxygen present in water, essential for the survival of fish, invertebrates, and microorganisms. Measured in milligrams per liter (mg\/L), DO levels are influenced by factors like temperature, pressure, salinity, and organic matter. Adequate dissolved oxygen is crucial for healthy aquatic ecosystems; low levels can cause hypoxia, harming aquatic life. Regular monitoring of DO is important for maintaining water quality in natural bodies of water and wastewater treatment.\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHigh Precision Measurement\u003c\/b\u003e: Utilizes cutting-edge optical technology for accurate and reliable dissolved oxygen readings.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRobust Design\u003c\/b\u003e: Suitable for challenging applications, the sensor boasts a long operational lifespan thanks to innovative light source technology.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFlexible Output Options\u003c\/b\u003e: Provides dual 4-20mA outputs for both dissolved oxygen and temperature measurements, ensuring compatibility with various systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eData Recording Capability\u003c\/b\u003e: Equipped with a built-in data logger, allowing users to easily access historical data and view trends via history curves.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting Versatility\u003c\/b\u003e: Can be panel-mounted, wall-mounted, or pipe-mounted, providing flexibility for installation in different environments.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRS485 Modbus Communication\u003c\/b\u003e: Direct integration with digital systems through RS485 Modbus RTU, facilitating easy data transmission and system integration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRelay Outputs\u003c\/b\u003e: Features three relay outputs—two configurable for high and low limit alarms and one for clean time settings.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIndustrial Wastewater Treatment\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDrinking Water Quality Monitoring\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePulp and Paper Processing\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eChemical Industry Applications\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eGeneral Water and Wastewater Treatment\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003eSpecifications\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\" height=\"1086\" style=\"width: 73.3878%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 33.9378%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cstrong\u003eInline Digital Dissolved Oxygen Meter\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eOnline measure dissolved oxygen and temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSensor Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWith Digital Dissolved Oxyen Sensor\u003c\/p\u003e\n\u003cp\u003e( Sensor with RS485 Modbus )\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e0~20.00 mg\/L\u003c\/p\u003e\n\u003cp\u003e0~200.00 %\u003c\/p\u003e\n\u003cp\u003e-10.0~100.0℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e±1%FS\u003c\/p\u003e\n\u003cp\u003e±0.5℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eData Recording Function\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCurrent output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003eIsolated type \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e2 ways of 4-20mA output \u003c\/p\u003e\n\u003cp\u003e(dissolved oxygen.temperature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTwo relays for high and low limit\u003c\/p\u003e\n\u003cp\u003eOne relay for clean\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 33.9378%;\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 64.5408%;\"\u003e138×138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel, Wall or Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital DO Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870006_Digital_DO_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital DO Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870006_Digital_DO_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435520736,"sku":"870006","price":948.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-optical-dissolved-oxygen-meter-870006-312466.jpg?v=1752691908"},{"product_id":"industrial-polarographic-dissolved-oxygen-sensor","title":"Online Industrial Polarographic Dissolved Oxygen Sensor","description":"\u003ch1\u003eThe Inline Industrial Polarographic Dissolved Oxygen Sensor features a significant upgrade from previous models, incorporating a grit mesh metal membrane instead of a traditional diaphragm.\u003c\/h1\u003e\n\u003cp\u003eThis enhancement provides increased stability and stress resistance, making it well-suited for harsher environments. It requires less maintenance and is ideal for continuous dissolved oxygen measurement in applications such as urban sewage treatment, industrial wastewater management, aquaculture and environmental monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnhanced design with a grit mesh metal membrane for superior stability and stress resistance.\u003c\/li\u003e\n\u003cli\u003eSuitable for challenging environments with reduced maintenance needs.\u003c\/li\u003e\n\u003cli\u003eIdeal for continuous monitoring of dissolved oxygen in urban sewage, industrial wastewater treatment, aquaculture, and environmental monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" style=\"width: 82.1072%; height: 316px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eUltra resistant to pressure (0.6M pa) wallop, imported (grit mesh metal membrane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 19.5938px;\"\u003e\u003cspan\u003eUp thread: M32 * 2.0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasuring range: \u003cbr\u003e0-20mg \/ L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasuring principle: Current type sensor (polarographic electrode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eBreathable membrane thickness: 100μm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eElectrode shell material: PVC or 316L stainless steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eTemperature compensation resistance: \u003cbr\u003ePt100, Pt1000, 22K, 2.252K, etc.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 19.5938px;\"\u003e\u003cspan\u003eSensor life: \u0026gt; 2 years\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 19.5938px;\"\u003e\u003cspan\u003eCable length: 5m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 19.5938px;\"\u003e\u003cspan\u003eDetection limit: \u003cbr\u003e0.01 mg \/ L (20 ℃)  \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasurement limit: \u003cbr\u003e20 mg \/ L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 19.5938px;\"\u003e\u003cspan\u003eResponse time: 2min (90%, 20 ℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 19.5938px;\"\u003e\u003cspan\u003ePolarization time: 60min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 19.5938px;\"\u003e\u003cspan\u003eMinimum flow rate: 2.5cm \/ s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 19.5938px;\"\u003e\u003cspan\u003eDrift: \u0026lt;2% \/ month\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasurement error: \u0026lt;± 0.01 mg \/ L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"606\" valign=\"top\" colspan=\"2\" style=\"width: 100.001%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput Current: 50-80nA\/0.1 mg \/ L  Note: Maximum current 3.5uA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 19.5938px;\"\u003e\u003cspan\u003ePolarization voltage: 0.7V  \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 19.5938px;\"\u003e\u003cspan\u003eZero oxygen: \u0026lt;0.01 mg \/ L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 55.0917%; height: 39.1875px;\"\u003e\u003cspan\u003eCalibration interval: \u0026gt; 60 days\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"303\" valign=\"top\" style=\"width: 44.9097%; height: 39.1875px;\"\u003e\u003cspan\u003eMeasured water temperature: \u003cbr\u003e32 - 140º F (0-60℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial DO Sensor - Instruction Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Industrial_Dissolved_Oxygen_Sensor_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial DO Sensor - Instruction Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Industrial_Dissolved_Oxygen_Sensor_User_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435586272,"sku":"870007-DO","price":752.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-polarographic-dissolved-oxygen-sensor-870007-do-554405.jpg?v=1752691865"},{"product_id":"optical-dissolved-oxygen-sensor","title":"Online Optical Dissolved Oxygen Sensor","description":"\u003ch1\u003eOur Online Optical Dissolved Oxygen Sensor sensor uses advanced fluorescence technology for dissolved oxygen measurement.\u003c\/h1\u003e\n\u003cp\u003eThe fluorescent dissolved oxygen (FDO) sensor utilizes fluorescence phase detection technology and proprietary algorithms to detect stable and sensitive changes in oxygen concentration or partial pressure. This sensor, which measures the lifetime of fluorescent molecules and their optical phase offset, offers high measurement accuracy compared to second-generation electrochemical measurement technology.\u003c\/p\u003e\n\u003cp\u003eIt's plug-and-play and requires no chemical reagents, making it an ideal choice for water quality testing in industries such as chemical engineering, biopharmaceuticals, nuclear power, sewage and wastewater treatment, and smart aquaculture. The sensor also boasts proprietary sensor membrane manufacturing technology, fluorescence phase detection algorithms, and electronic circuit hardware and software systems.\u003c\/p\u003e\n\u003cp\u003eThis sensor is widely used for continuous dissolved oxygen monitoring in sewage treatment processes, water plants, surface water, industrial process water, wastewater treatment, aquaculture and more.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProprietary sensor membrane manufacturing process, fluorescence oxygen phase algorithm, and electronic circuit hardware and software systems.\u003c\/li\u003e\n\u003cli\u003eWidely applicable in various applications (environmental protection, aquaculture, food processing, and other fields).\u003c\/li\u003e\n\u003cli\u003eStrong anti-interference capabilities.\u003c\/li\u003e\n\u003cli\u003eLow maintenance, long lifespan, and a long service life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Online \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"683\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDissolved Oxygen: 0–25 mg\/L (customizable up to 50 mg\/L)\u003cbr\u003eSaturation: 0–250%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e0–55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e-20–80°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eWorking Pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e500–1500 mbar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDO: ±0.1 mg\/L or ±1% (0–10 mg\/L)\u003cbr\u003eDO: ±0.3 mg\/L or ±3% (10–25 mg\/L)\u003cbr\u003eTemperature: ±0.2°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eT90 \u0026lt; 60 s (25°C)\u003cbr\u003eT95 \u0026lt; 90 s (25°C)\u003cbr\u003eT99 \u0026lt; 180 s (25°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eWaterproof Rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eIP68\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eTemperature Compensation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAutomatic, 0–55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePressure Compensation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e500–1500 mbar, automatic or manual setting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eSalinity Compensation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e0–55 ppt, automatic or manual setting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOne-point calibration: 100% air saturation\u003cbr\u003eTwo-point calibration: 100% air saturation and 0% oxygen (oxygen-free water)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMembrane Cap Material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePOM + PMMA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eSensor Body Material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eSS316L Stainless Steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eModbus RS485\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e9–36 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e6 mA (at 12 VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eStandard 10 m (custom lengths available)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"227\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eService Life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"455\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFluorescent membrane cap: 2 years (under normal maintenance conditions)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Optical DO Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Optical_DO_Sensor_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Optical DO Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Optical_DO_Sensor_User_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435619040,"sku":"870006-ODO","price":2124.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-optical-dissolved-oxygen-sensor-870006-odo-810063.jpg?v=1752691908"},{"product_id":"inline-digital-orp-sensor","title":"Online Digital ORP Sensor","description":"\u003ch1\u003eInline D\u003cmeta charset=\"utf-8\"\u003eigital ORP Sensor is a lightweight, high-precision electrode designed for easy installation and reliable, long-term performance.\u003c\/h1\u003e\n\u003cp\u003eWith a built-in temperature probe, it provides instant temperature compensation, ensuring accuracy and responsiveness. This sensor is highly resistant to interference and can be connected with output cables up to 500 meters in length. It allows for remote setup and calibration, making it user-friendly and ideal for ORP monitoring in various industries, including thermal power, fertilizer, metallurgy, environmental protection, pharmaceuticals, biochemistry, food and tap water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: right;\"\u003e\n\u003cli style=\"text-align: left;\"\u003eIndustrial-grade design suitable for long-term stable performance in sewage applications\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eBuilt-in temperature sensor with real-time temperature compensation\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eRS485 signal output with strong anti-interference, supporting cable lengths up to 500 meters\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eStandard Modbus RTU (485) communication protocol\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eRemote setup and calibration for easy operation and parameter adjustment\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eCompatible with 24V DC or 12V DC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 73.2062%; height: 593px;\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e870001-ORP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eParameter Measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eORP, Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e-2000mv~+2000mv\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eORP: ±0.1mv \u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eTemperature: ±1ºF (0.5℃)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1mV \u003c\/span\u003e\u003cspan\u003eTemperature: 0.1℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 34.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 34.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e24V DC \/ 12VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Dissipation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003e1W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eRS485 (Modbus RTU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eCan be ODM depend on user’s requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 55.1875px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSinking type, pipeline, circulation type, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eOverall Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e9x1.2 inches\u003cbr\u003e(230mm×30mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eABS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Digital_ORP_Sensor_User_Manual.pdf\" title=\"Inline Digital ORP Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Digital_ORP_Sensor_User_Manual.pdf\" title=\"Inline Digital ORP Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435782880,"sku":"870001-ORP","price":547.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-orp-sensor-870001-orp-313724.jpg?v=1752691897"},{"product_id":"multi-parameter-analyzer","title":"Online Multi-Parameter Water Quality Analyzer","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline Water Quality Meters and Sensors are sold separately - please be sure to add the appropriate sensor (listed above) when purchasing your meter - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMulti-Parameter Inline Water Quality Analyzer\u003c\/h1\u003e\n\u003cp\u003eThe Multi-Parameter Water Quality Analyzer is an advanced online analysis system designed for comprehensive water quality monitoring. It integrates up to eight (8) different water quality parameters into a single unit, which is \u003cmeta charset=\"utf-8\"\u003edisplayed and managed on a touch screen panel. This system combines real-time water quality analysis, remote data transmission, database management, analysis software, and system calibration functions into one convenient platform, streamlining water quality data collection and analysis.\u003c\/p\u003e\n\u003cp\u003eThe meter offers flexible configuration options, allowing you to customize the setup based on your specific needs. It supports a range of parameters including pH, ORP, dissolved oxygen, conductivity, temperature, ammonia (NH4+), COD, turbidity, and more. The system is equipped with a state-of-the-art tandem flow analysis device that requires minimal water and provides real-time results. Water samples pass through various sensors, capturing all parameters in real time and enabling easy expansion for larger-scale continuous monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable Parameters:\u003c\/strong\u003e Tailor monitoring parameters to your specific needs with flexible combinations and custom setups - connect up to eight digital sensors for simultaneous monitoring.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Monitoring:\u003c\/strong\u003e Achieve intelligent online monitoring through configurable software and parameter analysis modules.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Water Use:\u003c\/strong\u003e The integrated tandem flow device requires minimal water to perform diverse real-time analyses.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Maintenance:\u003c\/strong\u003e Automatic sensor and pipeline maintenance reduces manual intervention, simplifies complex field issues, and enhances measurement accuracy.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Flow Technology:\u003c\/strong\u003e Patented decompression and constant flow technology ensure stable data analysis by maintaining consistent flow rates despite pipeline pressure changes.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Data Options:\u003c\/strong\u003e Optional remote data links and database integration allow you to strategize and manage data from afar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.093%;\" class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 61.2274%;\" colspan=\"2\" width=\"403\"\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"68\"\u003e\u003cspan\u003e\u003cstrong\u003eSper #870001 Multi-Parameter Inline Water Quality Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61.2274%;\" colspan=\"2\" width=\"489\"\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"68\"\u003e\n\u003cp\u003e\u003cspan\u003epH,Conductivity, dissolved oxygen, COD, Turbidity, Suspended Solids, Ammonia, etc. (Note: the specific parameters to the actual ordering parameters prevail)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" rowspan=\"11\" colspan=\"1\" width=\"181\"\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"211\"\u003e\u003cspan\u003epH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"68\"\u003e\u003cspan\u003e0-14.00pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"148\"\u003e\u003cspan\u003eDO\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\u003cspan\u003e0-20.00mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"154\"\u003e\u003cspan\u003eORP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\n\u003cp\u003e\u003cspan\u003e-1999—1999mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"159\"\u003e\u003cspan\u003eConductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\u003cspan\u003e0~2000us\/cm (max to 2000ms\/cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"163\"\u003e\u003cspan\u003eTurbidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\u003cspan\u003e0-4000NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003e\u003cspan\u003eSuspended Solids (TSS)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e\u003cspan\u003e0~120 000mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eAmmonia\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003eNH4+:0~5000mg\/L, NH3-N:0~1000mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eCOD\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e0~1000mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e0 ~ 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eNitrate Nitrogen\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e0~100mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" rowspan=\"1\"\u003e(Note: Meter can be extended with other parameters, please confirm before ordering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"182\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\u003cspan\u003eRS485 Modbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"186\"\u003e\u003cspan\u003e\u003cstrong\u003eWireless\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\u003cspan\u003eLocal SIM card and \u003cmeta charset=\"utf-8\"\u003emobile app  (optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eData Logger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" rowspan=\"1\"\u003eYes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" rowspan=\"1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003e24V DC or 220V AC \u003cmeta charset=\"utf-8\"\u003e±10%\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003eWorking Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: 0-122ºF (0-50℃)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003eStorage Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003eRelative Humidity: ≤85% RH（without condensation）\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003eOther parameters can be customized based on requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Multi-Parameter Inline Water Quality Analyzer- Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001_Multi-Parameter_Water_Quality_Analyzer_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca title=\"Multi-Parameter Inline Water Quality Analyzer- Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001_Multi-Parameter_Water_Quality_Analyzer_Manual.pdf\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435946720,"sku":"870001","price":1819.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/multi-parameter-inline-water-quality-analyzer-870001-820665.jpg?v=1752691911"},{"product_id":"870002-online-ph-electrode","title":"Online Industrial Wastewater PH Sensor","description":"\u003ch1\u003eThe electrode features a world-class solid dielectric and a large PTFE liquid junction, ensuring a non-blocking design that is easy to maintain.\u003c\/h1\u003e\n\u003cp\u003eIts long-distance reference diffusion channel enhances durability, allowing it to withstand harsh environments for extended service life. The PPS\/PC casing, combined with a 3\/4NPT threaded pipe on both ends, simplifies installation without the need for a separate jacket, reducing overall installation costs. Equipped with a high-quality, low-noise cable, it maintains signal integrity for distances of over 20 meters without interference.\u003c\/p\u003e\n\u003cp\u003eWith no need for additional dielectric, this electrode requires minimal maintenance while offering high accuracy, quick response times, and excellent repeatability. It features a silver ion Ag\/AgCl reference electrode and proper use can further extend its service life. The electrode can be installed laterally or vertically in reaction tanks or pipelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolid dielectric and large PTFE liquid junction for low maintenance\u003c\/li\u003e\n\u003cli\u003eLong-distance reference diffusion channel for extended lifespan\u003c\/li\u003e\n\u003cli\u003eDurable PPS\/PC casing with 3\/4NPT threads for easy installation, no jacket required\u003c\/li\u003e\n\u003cli\u003eHigh-quality low-noise cable allows interference-free signal over 20 meters\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance with no need for additional dielectric\u003c\/li\u003e\n\u003cli\u003eHigh accuracy, fast response, and good repeatability\u003c\/li\u003e\n\u003cli\u003eSilver ion Ag\/AgCl reference electrode\u003c\/li\u003e\n\u003cli\u003eVersatile installation: lateral or vertical in tanks or pipelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable height=\"274\" border=\"1\" cellspacing=\"0\" style=\"width: 79.2007%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e0-14pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eTemperature \u003cmeta charset=\"utf-8\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e32-140\u003cmeta charset=\"utf-8\"\u003eºF (0-60℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.1439%;\"\u003e\u003cspan\u003eAccuracy \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8561%;\"\u003e\u003cspan\u003e±0.1 pH \/ ±0.5 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.1439%;\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003eTemperature Compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8561%;\"\u003e\u003cspan\u003e 10K, 2.252K, PT100, PT1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eCompressive Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e0.6 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eSlope\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e≥96％\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eZero point potential\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eE0=7 PH±0.3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eInternal impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e150-250 MΩ (25℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eNatural Tetrafluoro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eProfile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e3-in-1 Electrode (Integrating the temperature compensation and the solution grounding)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eInstallation size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eUpper and Lower 3\/4NPT Pipe Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eLow-noise cable goes out directly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eApplicable to various industrial sewage, environmental protection and water treatment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002-PH_Inline_Industrial_PH_Electrode_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002-PH_Inline_Industrial_PH_Electrode_User_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436143328,"sku":"870002-PH","price":179.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-wastewater-ph-sensor-870002-ph-611335.jpg?v=1752691881"},{"product_id":"industrial-ph-orp-meter","title":"Online Industrial PH \u0026 ORP Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Inline Industrial PH \u0026amp; ORP Meter offers stable and reliable operation designed to solve common issues faced by operators in water treatment and processing plants. \u003c\/h1\u003e\n\u003cp\u003eThese analyzers provide precise, continuous measurement, ensuring dependable water quality monitoring. Each pH and ORP meter is equipped with a transmitter and process adaptation, tailored to meet your specific pH control requirements. The meter delivers accurate readings in diverse environments, from ultra-pure water to bioreactor applications - even in challenging conditions like chemical production.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStable, precise, continuous measurement of pH, ORP and temperature\u003c\/li\u003e\n\u003cli\u003eFlexible installation options: panel, wall, or pipe-mounted\u003c\/li\u003e\n\u003cli\u003eDual 4-20mA outputs and standard RS485 Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eHigh\/low control relay functionality\u003c\/li\u003e\n\u003cli\u003eLocal data logging for up to 1,000 entries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications include industrial wastewater, drinking water monitoring, environmental monitoring, ultra-pure water, fermentation, food production and more.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\" style=\"width: 100%; height: 550px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper Scientific #870002 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003epH \/ ORP \/ Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e-2 ~16 pH, -2000 ~2000 mV, -30 ~130 ℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" colspan=\"1\" rowspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e0.05pH,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eThree relays, 5A\/250V AC      5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eHole Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436176096,"sku":"870002","price":661.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-ph-orp-meter-870002-793550.jpg?v=1752691886"},{"product_id":"online-acid-alkaline-concentration-meter","title":"Online Acid Alkaline Concentration Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Sper Scientific Inline Acid Alkali Concentration Meter is a smart, inline digital device designed for accurate measurement of acid and alkali concentrations.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring Parameters:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eConductivity, NaCl, HCl, NHO3, NaOH, H2SO4, KOH, Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis meter features a digital inductive conductivity sensor capable of measuring a variety of solutions, including \u003cstrong\u003ehydrochloric acid, nitric acid, sodium chloride, sodium hydroxide, potassium hydroxide and both dilute and concentrated sulfuric acid\u003c\/strong\u003e. It's advanced digital acid-base concentration sensor ensures precise and reliable monitoring across different applications.\u003c\/p\u003e\n\u003cp\u003eThis concentration meter is ideal for industries such as thermal power generation, chemical manufacturing and ion exchange processes where high-purity water production is critical. It is particularly useful for monitoring acid-base salt concentrations during processes like regenerating liquid concentration or controlling the solution concentration in boiler pipe pickling. Designed for continuous, real-time monitoring, it delivers dependable performance in demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmart, inline digital meter for accurate acid and alkali concentration measurement\u003c\/li\u003e\n\u003cli\u003eEquipped with a digital inductive conductivity sensor\u003c\/li\u003e\n\u003cli\u003eMeasures various solutions, including HCl, nitric acid, NaCl, NaOH, KOH, and sulfuric acid (dilute and concentrated)\u003c\/li\u003e\n\u003cli\u003eIdeal for thermal power, chemical industry, and ion exchange processes for high-purity water production\u003c\/li\u003e\n\u003cli\u003eEnsures precise control of acid-base salt concentration in continuous monitoring applications\u003c\/li\u003e\n\u003cli\u003eSuitable for regenerating liquid concentration and boiler pipe pickling solution configuration\u003c\/li\u003e\n\u003cli\u003eProvides real-time, continuous monitoring for reliable industrial performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eReal-Time Monitoring\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eReal-time analysis and adjustments for precise monitoring of acid-base concentrations in industrial processes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eOptimal Performance\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eWith its advanced technology, this analyzer ensures optimal performance and efficiency in various industrial applications by providing accurate and reliable data.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eThe user-friendly interface makes it easy to operate and allows for seamless monitoring and control of acid-base concentrations in industrial processes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eQuality construction ensures long-lasting reliability and stability, providing a dependable solution for continuous monitoring in industrial environments.\u003c\/div\u003e\n\u003cdiv class=\"ce-summary\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"ce-summary\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eMeter Specifications\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable style=\"border-collapse: collapse; width: 523pt;\" width=\"697\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 7296; width: 171pt;\" width=\"228\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 15018; width: 352pt;\" width=\"469\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.0pt;\" height=\"45\"\u003e\n\u003ctd style=\"height: 34.0pt; width: 171pt;\" width=\"228\" class=\"xl67\" height=\"45\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl68\"\u003e\u003cstrong\u003eSodium Chloride (NaCl) Concentration Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo ways of 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCurrent Output Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e±1%FS,±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eTemp. Measure Range\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eConductivity 0~2000ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e90 – 260V AC 50; 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo ways of 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eSize\/Weight\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e144×144×104mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePrinciple\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eInductive Conductivity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eConductivity 0~2000ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e±1%FS,±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo relays: 5A 250V AC; 5A 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e90 – 260V AC 50;60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"s1\"\u003eSensor Specifications \u003cbr\u003e(\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/online-acid-alkaline-concentration-meter\" rel=\"noopener\" target=\"_blank\"\u003eInline Acid-Alkaline Sensors\u003c\/a\u003e sold separately)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47008857587936\"\u003e870009-CS-PFA\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/online-acid-alkaline-concentration-meter\"\u003e870009-CS\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=54581983805664\" title=\"870009 CS2-PFA Sensor\"\u003e870009-CS2-PFA\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47009050231008\"\u003e870009-CS2\u003c\/a\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47009050231008\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eElectrode body material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"293\" nowrap colspan=\"2\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-20~80\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~125\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~150\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1mS\/cm ~ 2000mS\/cm\u003cbr\u003eHNO3: 0.00%~29.00%\/35.00%~96.00%(25C)\u003cbr\u003eH2SO4: 0.00%~29.00%\/30.00%~83.00%\/93.00%~99.00%(10°C)\u003cbr\u003eHCL: 0.00%~18.00%\/22.00%~39.00%(25°C) \u003cbr\u003eNaOH: :0.00%~14.00%\/18.00%~50.00%(25°C)\u003cbr\u003eNaCl:0.00%~26.00%(20°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e±2% of reading or  ± 1 mS\/cm, whichever is greater;  ±0.5\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMaximum pressure (bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOutput\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eModbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Acid Alkali Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Acid_Alkali_analyzer_manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Acid Alkali Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Acid_Alkali_analyzer_manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436241632,"sku":"870009","price":1030.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-acid-alkaline-concentration-meter-870009-354516.jpg?v=1752691908"},{"product_id":"online-total-suspended-solids-meter","title":"Online Total Suspended Solids Meter","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"e9712092-827b-4909-b36a-e40dccfa5e6f\" dir=\"auto\" class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+\u0026amp;]:mt-5\" data-message-model-slug=\"gpt-4o\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Digital Online TSS Meter is a high-precision instrument designed to measure Total Suspended Solids (TSS) in a variety of applications.\u003c\/h1\u003e\n\u003cp\u003eEquipped with an RS485 Online TSS Sensor, this meter provides accurate and reliable data, making it ideal for industrial and environmental monitoring.\u003c\/p\u003e\n\u003cp\u003eThe device features multiple output options including 4-20mA, RS485 Modbus RTU, and three relay outputs. Two relays can be set for high and low limit alarms, while the third relay is reserved for an automatic cleaning function. Additionally, the integrated datalogger allows for easy data management, enabling users to quickly download TSS measurements via a USB interface.\u003c\/p\u003e\n\u003cp\u003eIdeal for industrial water treatment, environmental monitoring, and other applications requiring precise suspended solid measurements, the Digital Online TSS Meter is both reliable and easy to use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Outputs and Relay Functions\u003c\/strong\u003e: Includes three configurable relays and two-way analog output for flexible control and data handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e: Designed to work with a single parameter sensor, ensuring precise and focused measurement of suspended solids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Transmitter Shell\u003c\/strong\u003e: The IP65-rated shell offers protection from dust and water, making it suitable for harsh environments. For outdoor use, additional protective measures are recommended to ensure long-term durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"ueditor_1568606020244\" class=\"noScrollMove\"\u003e\n\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable height=\"524\" style=\"width: 78.8374%;\" class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper Scientific #870005 Online TSS Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e90 ~260V AC 50\/60Hz\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP65 waterproof and dust rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e0~1000.00mg\/L\u003c\/p\u003e\n\u003cp\u003e0~99999.00 mg\/L\u003c\/p\u003e\n\u003cp\u003e99.99~120.0 g\/L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e±2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelays\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e5A\/250V AC, 5A\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4-20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDigital Communication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003eMODBUS RS485 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\" colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eHole Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\" colspan=\"1\" rowspan=\"1\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWarranty Period\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e1 year\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline TSS Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870005_TSS_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline TSS Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870005_TSS_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436405472,"sku":"870005","price":886.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-total-suspended-solids-meter-870005-831818.jpg?v=1752691912"},{"product_id":"digital-turbidity-meter","title":"Online Digital Turbidity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Sper Scientific Online Digital Turbidity Meter is a state-of-the-art instrument engineered for precise and reliable continuous turbidity measurement, conforming to international standards.\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSper Scientific Digital Turbidity Meter\u003c\/strong\u003e is an advanced instrument engineered for precise and reliable continuous turbidity measurement, adhering to international standards in a wide variety of applications. With a measuring range of \u003cstrong\u003e0-100.00 NTU\u003c\/strong\u003e, \u003cstrong\u003e0-3000.00 NTU\u003c\/strong\u003e, \u003cstrong\u003e0-4000.00 NTU\u003c\/strong\u003e and \u003cstrong\u003e0-10000.00 NTU\u003c\/strong\u003e, this meter is versatile and suitable for a variety of applications. Its advanced RS485 Modbus RTU digital turbidity sensor ensures accuracy and durability, making it an essential tool for effective water quality management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Measurement:\u003c\/strong\u003e Achieve high accuracy with a tolerance of ±2%, ensuring reliable turbidity readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Measuring Range:\u003c\/strong\u003e Handles turbidity levels from 0.01 NTU to 10,000 NTU, accommodating various water conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Service Life:\u003c\/strong\u003e Designed for extended operation, minimizing the need for frequent replacements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Calibration:\u003c\/strong\u003e Quick and easy calibration processes allow users to verify measurements in seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Connectivity:\u003c\/strong\u003e RS485 Modbus RTU interface enables seamless integration with existing monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatalogger:\u003c\/strong\u003e Built-in datalogger for recording measurements, facilitating long-term monitoring and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP65 rating ensures protection against dust and water ingress, suitable for various environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrinking and Process Water Monitoring:\u003c\/strong\u003e Ensures compliance with safety standards and optimal water quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess and Filter Monitoring:\u003c\/strong\u003e Facilitates efficient operation in industrial settings, monitoring filter performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Backwash Assessment:\u003c\/strong\u003e Provides critical data for filter maintenance in waterworks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Quality Monitoring in Distribution Networks:\u003c\/strong\u003e Supports utilities in maintaining high water quality throughout distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility Operations Across Industries:\u003c\/strong\u003e Versatile enough for various sectors, from manufacturing to municipal services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecirculation Lines:\u003c\/strong\u003e Monitors turbidity levels in recirculating systems to ensure water clarity and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Water Turbidity Monitoring:\u003c\/strong\u003e Essential for maintaining optimal conditions in cooling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"easytabs-undertabs-holder\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.091%;\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 27.7064%;\" colspan=\"1\" rowspan=\"1\" width=\"137\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" colspan=\"1\" rowspan=\"1\" width=\"357\"\u003e\u003cstrong\u003eOnline Digital Turbidity Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e0-100.00,0~3000.00 , 0-4000.00,10000.00 NTU\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" colspan=\"1\" rowspan=\"1\" width=\"137\"\u003e\u003cstrong\u003eUnit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" colspan=\"1\" rowspan=\"1\" width=\"357\"\u003eNTU \/ FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e± 2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCurrent output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e4-20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCommunication \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eRS485 Modbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e3 relays ,5A\/250V AC      5A\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverall dimension\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e144×144×104mm L*W*H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHole size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e138x138 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDatalogger\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCable length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e3 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Turbidity Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870004_Turbidity_Meter_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870004_Turbidity_Meter_User_Manual.pdf\" title=\"Inline Digital Turbidity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436438240,"sku":"870004","price":939.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-turbidity-meter-870004-461669.jpg?v=1752691910"},{"product_id":"inline-digital-suspended-solid-sensor","title":"Online Digital Suspended Solid Sensor","description":"\u003ch1\u003eThe Inline Digital Suspended Solid Sensor utilizes advanced infrared absorption and scattering light technology, in line with the ISO7027 standard, for highly accurate and continuous monitoring of suspended solids and sludge concentration.\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eBased on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of suspended solids and sludge concentration value. According to the usage environment, self-cleaning function can be equipped with. It assures the stability of data and reliability of performance; with the built-in self-diagnosis function, it can make sure the accurate data be delivered; besides, the installation and calibration is quite simple.  The product is widely used in sewage plant, water plant, water station, surface water, farming, industry and other fields.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared Dual Scattering Technology\u003c\/strong\u003e: Provides stable and accurate measurements unaffected by color variations in the sample.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO7027 Compliance\u003c\/strong\u003e: Ensures reliable and industry-standard measurements of suspended solids and sludge concentrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Cleaning Wiper Included\u003c\/strong\u003e: Available for environments prone to fouling, reducing maintenance and ensuring consistent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Self-Diagnostics\u003c\/strong\u003e: Monitors the sensor's performance and ensures accurate data output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple Installation and Calibration\u003c\/strong\u003e: Designed for easy setup and minimal calibration effort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\u003cspan\u003e0.01-20000 mg\/L, 0.01-45000 mg\/L, 0.01-120000 mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eCommunication\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eMain\u003c\/b\u003e\u003cb\u003e Materials\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp style=\"text-align: left;\" align=\"justify\"\u003e\u003cspan\u003eMain Body: SUS316L (Ordinary Version), Titanium Alloy (Seawater Version)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eUpper and Lower Cover:PVC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eCable: PVC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eWaterproof Rate\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eLess than ± 5% of the measured value \u003cbr\u003e(depending on sludge homogeneity)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003ePressure Range\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e≤0.4Mpa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eFlow\u003c\/b\u003e\u003cb\u003e velocity\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e≤2.5m\/s,8.2ft\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\" style=\"text-align: left;\"\u003e\u003cspan\u003eStorage Temperature: -15~65℃; Environment Temperature: 0~45℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eSample Calibration, Slope Calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eCable Length\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eStandard 10-Meter Cable, Max Length: 100 Meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eP\u003c\/b\u003e\u003cb\u003eower \u003c\/b\u003e\u003cb\u003eS\u003c\/b\u003e\u003cb\u003eupply\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e12 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"241\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cb\u003eSize\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"760\" valign=\"center\"\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eDiameter 60mm* Length 256mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Suspended_Solids_Sensor_Operation_Manual.pdf\" title=\"Inline Digital Suspended Solids Sensor  - Users Manual\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Suspended_Solids_Sensor_Operation_Manual.pdf\" title=\"Inline Digital Suspended Solids Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436503776,"sku":"870005-SS","price":2042.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-suspended-solid-sensor-870005-ss-849544.jpg?v=1752691909"},{"product_id":"turbidity-sensor","title":"Online Turbidity Sensor","description":"\u003ch1\u003eThe Online Digital Turbidity Sensor uses an advanced light scattering method, combining infrared absorption and infrared scattering.\u003c\/h1\u003e\n\u003cp\u003eInfrared light emitted from the source interacts with suspended particles in the sample, and the resulting scattered light is detected by a photodetector. This is then converted to an electrical signal, processed to yield an accurate turbidity reading through analog and digital signal processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrinking Water Treatment\u003c\/strong\u003e\u003cbr\u003eEnsure water meets regulatory standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWastewater Treatment\u003c\/strong\u003e\u003cbr\u003eMonitor effluent quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Monitoring\u003c\/strong\u003e\u003cbr\u003eAssess the clarity of lakes, rivers, and streams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Processes\u003c\/strong\u003e\u003cbr\u003eMaintain clarity in production lines, especially in food and beverage industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate and Reliable\u003c\/strong\u003e\u003cbr\u003eProvides consistent, precise measurements, ideal for laboratory and field use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Technology\u003c\/strong\u003e\u003cbr\u003eUtilizes high-precision sensors for reliable data, ensuring experimental integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e\u003cbr\u003eSimple, intuitive controls make it easy to operate for professionals and researchers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003cbr\u003eDesigned to withstand demanding laboratory conditions, offering reliable, long-lasting performance.\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIncluded self-cleaning wiper\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.469px;\" border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e0.01-100 NTU，0.01－4000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.9494%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%;\"\u003e\u003cspan\u003e0.01 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eLess than the measured value of ±1%, \u003cbr\u003eor ±0.1NTU，whichever is larger\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e≤0.4Mpa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCurrent Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e≤2.5m\/s, 8.2ft\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eSample calibration, slope calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 58.7812px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eSensor Main Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"368\" style=\"text-align: left; width: 74.0506%; height: 58.7812px;\"\u003e\u003cspan\u003eBody: SUS316L + PVC（normal type), SUS316L Titanium + PVC（sea water type)；O type circle：Fluorine rubber； cable：PVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e12V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication Interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eMODBUS  RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e5 to 149\u003cmeta charset=\"utf-8\"\u003eº F (-15 to 65℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e32 to 113\u003cmeta charset=\"utf-8\"\u003eºF (0 to 45℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e2.3 x 10 inches (60mm x 256mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e3.6lbs. (1.65kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eStandard 10m cable, can be extended to 100m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Turbidity_Sensor_User_Manual.pdf\" title=\"Inline Digital Turbisity Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Turbidity_Sensor_User_Manual.pdf\" title=\"Inline Digital Turbisity Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436536544,"sku":"870004-TB","price":2126.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-turbidity-sensor-870004-tb-338006.jpg?v=1752691889"},{"product_id":"wireless-module","title":"Wireless Module","description":"\u003cp class=\"p1\"\u003eGPRS gateway used by EMCP IOT cloud platform for MODBUS data automatic acquisition and transmission.\u003c\/p\u003e\n\u003ch4 class=\"p1\"\u003eDownloads\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Datasheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Product Datasheet\" rel=\"noopener\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47407009661152,"sku":"870012","price":1049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/wireless-module-wm-6099-101565.jpg?v=1748137960"},{"product_id":"conductivity-salinity-sensor-fits-multi-parameter-sensor-housing","title":"Conductivity\/Salinity Sensor - Fits Multi-Parameter Sonde","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1 style=\"text-align: left;\"\u003eAdvanced Conductivity\/Salinity Sensor is designed to fit the Multi-Parameter Sensor Housing.\u003c\/h1\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"color: rgb(255, 42, 0); font-size: 0.875rem;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNotes\u003c\/span\u003e:\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e1) This is for the SENSOR ONLY and requires use of the \u003ca href=\"https:\/\/sperdirect.com\/products\/multi-parameter-sonde-water-quality-sensor-housing\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Parameter Sensor Housing\u003c\/a\u003e. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2) The sensor housing can be connected to either the \u003ca href=\"https:\/\/sperdirect.com\/products\/portable-multi-parameter-water-quality-analyzer\"\u003ePortable Multi-Parameter Water Quality Analyzer\u003c\/a\u003e, or integrated with 3rd party data loggers or remote monitoring systems via \u003cspan class=\"Apple-converted-space\"\u003ebuilt-in \u003c\/span\u003eRS485 Modbus output.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e3) This unit ships direct from the factory. Please allow an additional 5-10 working days for shipment and delivery.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.sper-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 20px;\n}\n\n.sper-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 16px;\n  background: #fff;\n  transition: box-shadow 0.2s ease;\n  display: flex;\n  flex-direction: column;\n}\n\n.sper-card:hover {\n  box-shadow: 0 4px 12px rgba(0,0,0,0.08);\n}\n\n.sper-card img {\n  width: 100%;\n  height: auto;\n  margin-bottom: 12px;\n  display: block;\n}\n\n.sper-title {\n  font-size: 16px;\n  font-weight: 600;\n  margin-bottom: 6px;\n  line-height: 1.3;\n}\n\n.sper-desc {\n  font-size: 14px;\n  margin-bottom: 12px;\n  line-height: 1.4;\n  color: #444;\n}\n\n.sper-specs {\n  font-size: 13px;\n  line-height: 1.6;\n  margin-top: auto;\n}\n\n.sper-spec-row {\n  display: grid;\n  grid-template-columns: 120px 1fr;\n  gap: 6px;\n  margin-bottom: 2px;\n}\n\n.sper-spec-label {\n  font-weight: 600;\n  color: #222;\n}\n\n.sper-spec-value {\n  color: #333;\n}\n\u003c\/style\u003e\n\u003c!-- Conductivity --\u003e\n\u003cdiv class=\"sper-card\"\u003e\n\u003cdiv class=\"sper-title\"\u003eConductivity \/ Salinity Sensor\u003c\/div\u003e\n\u003cdiv class=\"sper-desc\"\u003eDual-range conductivity sensor for freshwater and high-salinity environments.\u003c\/div\u003e\n\u003cdiv class=\"sper-specs\"\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003ePlatinum electrode\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eRange\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e1–2000 µS\/cm, 100 µS\/cm–100 mS\/cm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.1 µS\/cm–0.01 mS\/cm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eAccuracy\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e±3%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":51416366612704,"sku":"870015-CS","price":677.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/conductivitysalinity-sensor-fits-multi-parameter-sonde-870015-cs-6017359.jpg?v=1793167087"},{"product_id":"nitrate-ion-sensor-fits-multi-parameter-sensor-housing","title":"Nitrate Ion Sensor - Fits Multi-Parameter Sonde","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1 style=\"text-align: left;\"\u003eAdvanced Nitrate Ion Sensor is designed to fit the Multi-Parameter Sensor Housing.\u003c\/h1\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"color: rgb(255, 42, 0); font-size: 0.875rem;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNotes\u003c\/span\u003e:\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e1) This is for the SENSOR ONLY and requires use of the \u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/products\/multi-parameter-sonde-water-quality-sensor-housing\" target=\"_blank\"\u003eMulti-Parameter Sensor Housing\u003c\/a\u003e. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2) The sensor housing can be connected to either the \u003ca href=\"https:\/\/sperdirect.com\/products\/portable-multi-parameter-water-quality-analyzer\"\u003ePortable Multi-Parameter Water Quality Analyzer\u003c\/a\u003e, or integrated with 3rd party data loggers or remote monitoring systems via \u003cspan class=\"Apple-converted-space\"\u003ebuilt-in \u003c\/span\u003eRS485 Modbus output.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e3) This unit ships direct from the factory. Please allow an additional 5-10 working days for shipment and delivery.\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.sper-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 20px;\n}\n\n.sper-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 16px;\n  background: #fff;\n  transition: box-shadow 0.2s ease;\n  display: flex;\n  flex-direction: column;\n}\n\n.sper-card:hover {\n  box-shadow: 0 4px 12px rgba(0,0,0,0.08);\n}\n\n.sper-card img {\n  width: 100%;\n  height: auto;\n  margin-bottom: 12px;\n  display: block;\n}\n\n.sper-title {\n  font-size: 16px;\n  font-weight: 600;\n  margin-bottom: 6px;\n  line-height: 1.3;\n}\n\n.sper-desc {\n  font-size: 14px;\n  margin-bottom: 12px;\n  line-height: 1.4;\n  color: #444;\n}\n\n.sper-specs {\n  font-size: 13px;\n  line-height: 1.6;\n  margin-top: auto;\n}\n\n.sper-spec-row {\n  display: grid;\n  grid-template-columns: 120px 1fr;\n  gap: 6px;\n  margin-bottom: 2px;\n}\n\n.sper-spec-label {\n  font-weight: 600;\n  color: #222;\n}\n\n.sper-spec-value {\n  color: #333;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"sper-grid\"\u003e\n\u003c!-- Nitrate --\u003e\n\u003cdiv class=\"sper-card\"\u003e\n\u003cdiv class=\"sper-title\"\u003eNitrate Ion Sensor\u003c\/div\u003e\n\u003cdiv class=\"sper-desc\"\u003eISE nitrate sensor for nutrient monitoring.\u003c\/div\u003e\n\u003cdiv class=\"sper-specs\"\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003eIon-selective electrode\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eRange\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.5–100 mg\/L\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.01–1 mg\/L\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eAccuracy\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e±10% or ±2 mg\/L\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":51418070057184,"sku":"870015-NI","price":3000.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/nitrate-ion-sensor-fits-multi-parameter-sonde-870015-ni-4451383.jpg?v=1793167089"},{"product_id":"vp-cable-5-meters","title":"Bioprocess Analytics Sensor Cable","description":"\u003ch1\u003e5 meter sheathed cable with female VP, AK9 or AS9 type connectors.\u003c\/h1\u003e\n\u003cp\u003e5 meter cable with VP, AK9 or AS9 type connector for Bio-Analytics probes and sensors.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Select one \u003e","offer_id":67912840282336,"sku":null,"price":122.0,"currency_code":"USD","in_stock":true},{"title":"VP8 Cable - 5 meters | VP8-5M","offer_id":67912840184032,"sku":"SSVP8-5M","price":337.0,"currency_code":"USD","in_stock":true},{"title":"AK9 Cable - 5 meters | AK9-5M","offer_id":67912840216800,"sku":"SSAK9-5M","price":122.0,"currency_code":"USD","in_stock":true},{"title":"AS9 Cable - 5 meters | AS9-5M","offer_id":67912840249568,"sku":"SSAS9-5M","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/bioprocess-analytics-sensor-cable-4673593.jpg?v=1791990916"},{"product_id":"bioprocess-analytics-sensor-ph-sheath","title":"pH Sheath for Bioprocess Analytics Sensor","description":"\u003ch1\u003epH Sheath\u003c\/h1\u003e\n\u003cp\u003eStandard length for 12*120mm sensor.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":67913127428320,"sku":"SSSH-101 316L","price":337.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/ph-sheath-for-bioprocess-analytics-sensor-8672256.png?v=1791990915"},{"product_id":"online-universal-water-quality-transmitter","title":"Online Universal Water Quality Transmitter","description":"\u003ch1\u003eUniversal Transmitter provides continuous online water quality monitoring when paired with a compatible BOQU digital sensor. \u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurations support pH, ORP, residual chlorine, dissolved oxygen, turbidity or suspended solids, with temperature measurement available where supported by the selected sensor.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for panel installation, the DA800 combines a 3.1-inch backlit LCD and five-button interface with two 4–20 mA outputs and RS485 Modbus RTU communication. These interfaces support connection to PLCs and plant monitoring systems, while three relays provide high alarm, low alarm and cleaning control functions.\u003c\/p\u003e\n\u003cp\u003eHistorical data logging supports adjustable recording intervals from 1–999 minutes. Stored readings can be viewed on the instrument or exported to a computer in CSV format through the USB Type-C port. A maintenance mode holds the 4–20 mA and RS485 output values during service, while simulation functions help check current outputs and relay operation.\u003c\/p\u003e\n\u003cp\u003eThe IP65-rated ABS housing and 4 W power consumption suit fixed monitoring installations in water treatment, wastewater treatment, industrial process water, aquaculture and biological fermentation. The standard power configuration accepts 100–240 VAC; a 24 VDC version is optional.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with supported Sper Scientific digital sensors for multiple water quality applications\u003c\/li\u003e\n\u003cli\u003e3.1-inch backlit LCD with measurement, status, date and time display\u003c\/li\u003e\n\u003cli\u003eDual 4–20 mA outputs and RS485 Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eThree relays for high alarm, low alarm and cleaning control\u003c\/li\u003e\n\u003cli\u003eHistorical data recording with adjustable storage intervals\u003c\/li\u003e\n\u003cli\u003eCSV data export through USB Type-C\u003c\/li\u003e\n\u003cli\u003eMaintenance mode holds output values during service\u003c\/li\u003e\n\u003cli\u003eCurrent output and relay simulation for system checks\u003c\/li\u003e\n\u003cli\u003ePower-loss data retention\u003c\/li\u003e\n\u003cli\u003eIP65-rated ABS enclosure for panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870016\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSupported parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH, ORP, residual chlorine, dissolved oxygen, turbidity, suspended solids and temperature; configuration depends on the connected sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard power supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional power supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo 4–20 mA outputs; functions depend on sensor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eThree; high alarm, low alarm and cleaning control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelay contact rating\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 A at 250 VAC or 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData logging interval\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eAdjustable from 1–999 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData export\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUSB Type-C connection to a computer; CSV export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to 50°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOvervoltage category \/ pollution degree\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eII \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSensor-dependent measurement ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eORP\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResidual chlorine\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDissolved oxygen\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–25 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–4,000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSuspended solids\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–120,000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese ranges describe the controller's supported configurations. Actual range, accuracy, temperature capability and process limits depend on the selected electrode or sensor. The transmitter does not measure every listed parameter simultaneously.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/DA800_Universal_Transmitter_Manual.pdf\" title=\"Sper 870016 Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/DA800_Universal_Transmitter_Manual.pdf\" title=\"Sper 870016 Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eSper 870016 Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DA800 measure all listed parameters at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Supported measurements and menu functions depend on the connected sensor and selected configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It provides RS485 Modbus RTU communication and two 4–20 mA outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I export recorded readings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Stored data can be copied to a computer in CSV format over USB. Logging pauses while the USB connection is active and resumes after disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes every sensor configuration measure temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The manual states that turbidity and suspended solids configurations do not provide the temperature setting function. Check the selected sensor's capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard version uses 100–240 VAC at 50\/60 Hz. A 24 VDC version is optional.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat determines measurement accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy and usable measurement range depend on the compatible sensor selected. Refer to that sensor's specifications and calibration requirements.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68103962591456,"sku":"870016","price":997.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-universal-water-quality-transmitter-870016-2499980.jpg?v=1793360781"},{"product_id":"sper-scientific-ph-conductivity-dual-channel-online-analyzer","title":"Online Dual-Channel pH\/Conductivity Analyzer","description":"\u003ch1\u003eSper Scientific Online pH\/Conductivity Analyzer monitors one analog pH or ORP sensor and one analog conductivity sensor simultaneously.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIt combines two measurement channels in a compact panel-mounted instrument for continuous water quality monitoring in industrial processes, water treatment and wastewater applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe pH\/ORP channel supports acidity or oxidation-reduction potential measurement, while the conductivity channel provides conductivity, TDS, salinity or resistivity readings. Temperature measurement and compensation support consistent process evaluation when used with compatible probes. Actual measurement range, process temperature limits and overall system performance depend on the sensors selected.\u003c\/p\u003e\n\u003cp\u003eA 3.1-inch backlit LCD displays process readings, while the front-panel buttons provide access to measurement and output settings. Two configurable 4–20 mA outputs and RS485 Modbus RTU communication support integration with PLCs and plant monitoring systems. Three relay outputs provide alarm and supported control functions.\u003c\/p\u003e\n\u003cp\u003eHistorical data records and trend curves help review process changes. Recording intervals can be set from 1–999 minutes, and stored data can be exported to a computer over USB. The ABS enclosure has an IP65 protection rating, with standard 100–240 VAC power and an optional 24 VDC configuration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous pH\/ORP and conductivity monitoring with compatible analog sensors\u003c\/li\u003e\n\u003cli\u003eConductivity-channel functions include EC, TDS, salinity and resistivity\u003c\/li\u003e\n\u003cli\u003eTemperature compensation with multiple supported temperature sensor types\u003c\/li\u003e\n\u003cli\u003e3.1-inch backlit LCD and front-panel controls\u003c\/li\u003e\n\u003cli\u003eTwo configurable 4–20 mA outputs\u003c\/li\u003e\n\u003cli\u003eRS485 Modbus RTU communication for PLC integration\u003c\/li\u003e\n\u003cli\u003eThree relay outputs for alarm and supported control functions\u003c\/li\u003e\n\u003cli\u003eHistorical data logging and trend curve display\u003c\/li\u003e\n\u003cli\u003eAdjustable data recording intervals from 1–999 minutes\u003c\/li\u003e\n\u003cli\u003eUSB export of stored records\u003c\/li\u003e\n\u003cli\u003eIP65-rated ABS enclosure\u003c\/li\u003e\n\u003cli\u003eStandard AC power with an optional 24 VDC version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement channels\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne analog pH\/ORP sensor and one analog conductivity sensor, operating simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eORP range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eConductivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000,000 µS\/cm (0–2,000 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTDS range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResistivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSalinity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSupported; usable range depends on sensor and configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 1 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30.0 to 130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 2 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40.0 to 200.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH: ±0.01 pH; ORP: ±1 mV; conductivity: ±2%; temperature: ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation inputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eNTC30k, NTC22k, NTC10k, Pt1000 and NTC2.252k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo configurable 4–20 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDigital interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eThree; contacts rated 5 A at 250 VAC or 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData logging\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eHistorical records and curves; adjustable recording interval 1–999 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData export\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUSB connection to computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHousing \/ protection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm \/ 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to 50°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAltitude \/ overvoltage category \/ pollution degree\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤2,000 m \/ II \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eLanguages\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eEnglish, Simplified Chinese, Traditional Chinese and Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCountry of origin\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eListed measurement limits are controller capabilities. Select compatible electrodes with ranges, temperature ratings and process connections appropriate for the application.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e\u003cbr\u003eSper Scientific 870002D Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DCA130 measure pH and conductivity at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports one pH\/ORP sensor and one conductivity sensor simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it measure pH and ORP simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe first channel uses a pH or ORP sensor. The second channel is intended for conductivity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat measurements are available on the conductivity channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConductivity, TDS, salinity and resistivity functions are supported. Available ranges depend on the electrode and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The analyzer provides RS485 Modbus RTU and two configurable 4–20 mA outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan historical readings be exported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Stored data can be exported to a computer over USB. Logging pauses while the USB connection is active and resumes after disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre sensors included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSensor inclusion has not been specified. Select the required pH\/ORP and conductivity probes for your installation and confirm the package before ordering.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68104970076384,"sku":"870002D","price":947.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-dual-channel-phconductivity-analyzer-870002d-1476214.jpg?v=1793360781"},{"product_id":"online-multi-parameter-water-quality-analyzer","title":"Online Multi-Parameter Water Quality Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870001S Multi-Parameter Water Quality Analyzer combines online pH, residual chlorine, turbidity and temperature monitoring in an integrated cabinet.\u003c\/h1\u003e\n\u003cp\u003eDesigned for waterworks, municipal water supply and drinking water monitoring in public facilities, it brings key water quality measurements together in one installation.\u003c\/p\u003e\n\u003cp\u003eThe compact cabinet simplifies equipment placement and reduces the space required for a monitoring station. A front-mounted display provides access to process information, while the internal arrangement groups the measurement components, sample tubing and connections for service access. Online monitoring and stored data help operators review water quality conditions and changes over time.\u003c\/p\u003e\n\u003cp\u003eRS485 communication supports connection to compatible monitoring equipment. The system is intended for water supply applications under normal temperature and pressure conditions. Parameter customization is available at the product-family level; confirm the required sensors and configuration for the installation before ordering.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated online monitoring of pH, residual chlorine, turbidity and temperature\u003c\/li\u003e\n\u003cli\u003eCabinet-based design simplifies transportation and installation\u003c\/li\u003e\n\u003cli\u003eFront-mounted display for water quality information\u003c\/li\u003e\n\u003cli\u003eOnline data monitoring and storage\u003c\/li\u003e\n\u003cli\u003eRS485 communication interface\u003c\/li\u003e\n\u003cli\u003eAccessible internal measurement components and sample connections\u003c\/li\u003e\n\u003cli\u003eCompact 400 × 600 × 220 mm cabinet\u003c\/li\u003e\n\u003cli\u003eSuitable for waterworks, municipal supply and drinking water monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH, residual chlorine, turbidity and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14.00 pH \/ 0.01 pH \/ ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResidual chlorine range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2.00 mg\/L \/ 0.01 mg\/L \/ ±3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity range \/ resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2.00 NTU \/ 0.01 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2% or ±0.02 NTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C \/ 0.1°C \/ ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCommunication interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHumidity condition\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCabinet dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e400 × 600 × 220 mm (L × H × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68119237656800,"sku":"870001S","price":4300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-multi-parameter-water-quality-analyzer-870001s-3724419.jpg?v=1793360780"},{"product_id":"open-channel-flow-meter","title":"Open Channel Flow Meter","description":"\u003ch1\u003eThe Sper Scientific Open Channel Flow Meter calculates water flow from measured liquid level and the level-to-flow relationship of a compatible measuring weir.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eApplications include wastewater discharge points and municipal sewer channels.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThe wall-mounted ultrasonic open channel flow meter measures water level without contacting the liquid. A sensor transmits ultrasonic pulses toward the water surface and measures the time taken for the echoes to return. The meter uses this distance measurement to determine water level, then calculates flow using the level-to-flow relationship for the configured weir or flume.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe display shows instantaneous flow rate, accumulated flow and water level. Non-contact measurement keeps the sensor away from wastewater, reducing exposure to contamination and corrosion. Accurate flow measurement requires a compatible measuring structure, proper installation and suitable free-flow conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis method is used to monitor water and wastewater flow in open channels, including wastewater treatment plant discharge channels, industrial effluent outlets and municipal sewer systems. Accurate results depend on proper weir installation, correct level measurement and selection of the appropriate flow calculation.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWater and wastewater treatment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower generation and mining\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFood processing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePetrochemical facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntake channels, drainage channels and discharge outlets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStream and river monitoring at suitable measuring structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegration with process monitoring and control systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMain Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWater level, instantaneous flow and accumulated flow display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSettings backup and restoration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConfigurable analog output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDigital filtering and echo recognition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManually configurable suppression of fixed interference echoes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCustom mathematical calculations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable sound velocity for specific measurement conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLevel-to-volume conversion for configured vessels; weight calculation requires appropriate volume and density settings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBluetooth, GPRS and Wi-Fi connectivity, depending on configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional custom serial data format, specified when ordering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Mini SD card data logging, USB output and microprinter support, specified when ordering\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eFlow range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 L\/s–10 m³\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eFlow accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±1–3%, depending on measuring weir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMaximum level\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLevel accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.3% within 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTotalizer\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e12-digit decimal; resets when accumulation capacity is reached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRelay options\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1–4 outputs; please specify when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower options\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC, 50 Hz or 12–36 VDC, 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSignal input (Please specify when ordering)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003eDigital signal: RS485 (supports Modbus protocol)\u003cbr\u003eCurrent signal: 4-20mA\u003cbr\u003eTransducer signal: voltage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSignal output (Please specify when ordering)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003eVoltage output: DC12V or 24V\u003cbr\u003eAnalog output signal: 0 ~ 20mA; 4 ~ 20mA load \u0026gt; 300Ω; 0 ~ 5V; 0 ~ 10V\u003cbr\u003eDigital output: RS485 (support Modbus); USB, memory card 8G\u003cbr\u003eWireless transmission: built-in GPRS wireless communication optional SMS data prompt (acquisition system can be customized)\u003cbr\u003eSwitch output: two NPN\/3 relays (AC: 5A 250V DC: 10A 24V)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003eWorking voltage: DC12-24V or AC160V~250V\u003cbr\u003eNormal power consumption: \u0026lt;5W\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/OCFM_Open-channel_flow_meter.doc\" title=\"Open Channel Flow Meter Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/OCFM_Open-channel_flow_meter.doc\" title=\"Open Channel Flow Meter Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eSper Scientific Open Channel Flow Meter Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHow is flow determined?\u003c\/strong\u003e\u003cbr\u003eFrom liquid level and the selected weir’s level-to-flow relationship.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat affects flow accuracy?\u003c\/strong\u003e\u003cbr\u003eThe measuring weir used in the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68122682392800,"sku":"870023","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/open-channel-flow-meter-870023-9595764.webp?v=1793360777"},{"product_id":"explosion-proof-online-ph-orp-analyzer","title":"Explosion-Proof Online pH\/ORP Analyzer","description":"\u003ch1\u003eThe Sper Scientific Explosion-Proof Online pH\/ORP Analyzer supports continuous pH or ORP and temperature monitoring with a compatible analog electrode.\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sper Scientific 870002E\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e monitors pH or oxidation-reduction potential (ORP) in industrial water and process solutions.\u003c\/strong\u003e Its online design provides continuous readings, helping operators track changing conditions throughout a process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConnect a compatible analog pH or ORP sensor to measure the selected parameter along with temperature. The analyzer sends a 4–20 mA signal to connected monitoring equipment, allowing readings to be incorporated into a plant’s process monitoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 870002E is suited to applications such as wastewater treatment, drinking water processing, chemical production and power generation. Its explosion-proof design and low power consumption support use in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous online monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of pH or ORP and temperature\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAnalog sensor compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the selected measurement\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTwo-wire 4–20 mA output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for connection to monitoring equipment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eExplosion-proof design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for suitable industrial applications\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for continuous operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002E\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003epH range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2 to 16 pH \/ ±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eORP range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV \/ ±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130°C \/ ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e18–30 VDC; 0.66 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo-wire 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eAluminum; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to +50°C; 0–95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +70°C; 0–95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68185306169568,"sku":"870002E","price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/explosion-proof-online-phorp-analyzer-870002e-8819373.jpg?v=1793360781"},{"product_id":"explosion-proof-two-wire-online-conductivity-analyzer","title":"Explosion-Proof Two-Wire Online Conductivity Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870003E Two-Wire Explosion-Proof Online Conductivity Analyzer supports continuous conductivity, salinity, TDS, resistivity and temperature monitoring with a compatible analog sensor.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sper Scientific 870003E 2-Wire Explosion-Proof Online Electrical Conductivity Analyzer\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e provides continuous monitoring of conductivity, salinity, total dissolved solids (TDS), resistivity and temperature in water and process solutions.\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsed with a compatible analog conductivity sensor, it is suitable for wastewater treatment, power generation, chemical processing, pharmaceutical manufacturing, food processing and drinking water applications. \u003c\/span\u003e\u003cspan\u003eA two-wire 4–20 mA output connects the analyzer to process monitoring equipment, while low power consumption supports continuous operation in industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe analyzer features a die-cast aluminum housing with an IP65 rating for protection against dust and water. Its construction supports use in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eContinuous monitoring of conductivity, salinity, TDS, resistivity and temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with analog conductivity sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-wire 4–20 mA output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDie-cast aluminum housing with IP65 protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExplosion-proof design with manufacturer-listed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEx ia IIC T6 Ga\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e marking\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870003E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 0.01\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.01–20 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 0.1\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1–200 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 1.0\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1–2,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 10.0\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e10–20,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSalinity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.00–80.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTDS\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResistivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature inputs \/ ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000 or NTC10k: −40 to +200°C; NTC2.252k: −30 to +150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5% F.S.; temperature ±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne two-wire 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±0.3% F.S. or ±0.05 mA, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e18–30 VDC; 0.66 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDie-cast aluminum; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 147 mm; 1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to +60°C; ≤95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68188570747104,"sku":"870003E","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/explosion-proof-two-wire-online-conductivity-analyzer-870003e-3346998.jpg?v=1793360779"},{"product_id":"online-industrial-orp-sensor","title":"Online Industrial ORP Sensor","description":"\u003ch1\u003eThe Sper Scientific Industrial ORP Sensor monitors oxidation-reduction potential in water and process solutions.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for use with compatible ORP monitoring equipment, the sensor helps operators track redox conditions in applications such as water treatment, wastewater processing, cooling water and industrial chemical processes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe platinum sensing element is paired with a solid reference electrolyte and a large-area PTFE junction. Upper and lower 3\/4-inch NPT threads provide installation options, while a direct-connected low-noise cable carries the sensor signal.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eORP measurement from −2,000 to +2,000 mV\u003c\/li\u003e\n\u003cli\u003ePlatinum sensing element\u003c\/li\u003e\n\u003cli\u003eSolid reference electrolyte and PTFE junction\u003c\/li\u003e\n\u003cli\u003eUpper and lower threaded connections\u003c\/li\u003e\n\u003cli\u003eDirect-connected low-noise cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002-ORP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOxidation-reduction potential (ORP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eORP range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePressure rating\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBody material\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePPS\/PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSensing element\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eReference junction\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProcess connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eUpper and lower 3\/4-inch NPT threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDirect-connected low-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68288733970656,"sku":"870002-ORP","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-orp-sensor-870002-orp-2854675.jpg?v=1793360775"},{"product_id":"industrial-glass-ph-electrode","title":"Online Industrial Glass pH Electrode - Waste Water (PTFE)","description":"\u003ch1\u003eThe Industrial Glass pH electrode supports continuous online monitoring in wastewater and environmental applications.\u003c\/h1\u003e\n\u003cp\u003eThis cable-connected combination electrode features a low-resistance sensing membrane and a ceramic-infiltrated sand core junction. Its pressure-resistant design is suited to industrial pH measurement and long-term online monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures pH from 0 to 14\u003c\/li\u003e\n\u003cli\u003eCable-type connection\u003c\/li\u003e\n\u003cli\u003eLow-resistance glass sensing membrane\u003c\/li\u003e\n\u003cli\u003eCeramic-infiltrated sand core junction\u003c\/li\u003e\n\u003cli\u003eDesigned for environmental and wastewater monitoring\u003c\/li\u003e\n\u003cli\u003eCan be used with a 316L stainless steel or PPS sheath\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e870002-PHG1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range\u003c\/td\u003e\n\u003ctd\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e0–80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure resistance\u003c\/td\u003e\n\u003ctd\u003e0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection type\u003c\/td\u003e\n\u003ctd\u003eCable type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction material\u003c\/td\u003e\n\u003ctd\u003eCeramic-infiltrated sand core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eEnvironmental protection and wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68290605875424,"sku":"870002-PHG1","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-glass-ph-electrode-waste-water-ptfe-870002-phg1-4359559.png?v=1793360775"},{"product_id":"online-industrial-pressure-sensor-0-100-mpa-4-20-ma","title":"Online Industrial Pressure Sensor, 0–100 MPa, 4–20 mA","description":"\u003ch1\u003eHigh-Accuracy Industrial Pressure Measurement for Water Treatment and Process Control\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific 870023-PS Pressure Sensor is an industrial silicon pressure transmitter designed for monitoring compatible liquids in water treatment, wastewater and industrial process applications. Its 316L stainless steel wetted parts, 4–20 mA output and rugged stainless steel housing support reliable integration with process control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePressure measurement range: 0–100 MPa\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±0.25% FSO\u003c\/li\u003e\n\u003cli\u003e4–20 mA analog output with 24 VDC supply\u003c\/li\u003e\n\u003cli\u003e316L stainless steel wetted parts and silicon pressure membrane\u003c\/li\u003e\n\u003cli\u003e200% FS overload pressure and 250% FS burst pressure\u003c\/li\u003e\n\u003cli\u003eDIN 43650 electrical connector and IP65 protection\u003c\/li\u003e\n\u003cli\u003eBSP 1\/4-inch male process connection or customized connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eIndustrial automation, water and wastewater treatment, chemical processing and compatible liquid pressure monitoring.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProduct\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eSper 870023-PS Pressure Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement media\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eLiquids compatible with 316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOverload pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e200% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBurst pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e250% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eZero offset\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1% FSO maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.25% FSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLong-term zero stability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.15% FSO\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLoad resistance\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e250–1150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProcess connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eBSP 1\/4-inch male or customized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDIN 43650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eEnvironmental protection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePressure membrane\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWetted parts\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68312327192800,"sku":"870023-PS","price":237.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-pressure-sensor-0-100-mpa-4-20-ma-870023-ps-5901014.jpg?v=1793360774"},{"product_id":"online-industrial-conductivity-sensor-with-dual-3-4-inch-thread","title":"Online Industrial Conductivity Sensor with Dual 3\/4-Inch Thread","description":"\u003ch1\u003eIndustrial Conductivity Monitoring with Dual 3\/4-Inch Threaded Installation\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific 870003-ICE Industrial Conductivity Sensor is an analog electrode designed for measuring conductivity in pure water, reverse osmosis systems, hydroponics and industrial water treatment. Its dual 3\/4-inch threaded design supports versatile process installation, while corrosion-resistant electrode materials and optional temperature compensation provide stable conductivity monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog mV output for compatible conductivity controllers\u003c\/li\u003e\n\u003cli\u003eDual 3\/4-inch threaded installation\u003c\/li\u003e\n\u003cli\u003eAvailable conductivity ranges for low- and moderate-conductivity water\u003c\/li\u003e\n\u003cli\u003e±2% full-scale accuracy and response time under 60 seconds\u003c\/li\u003e\n\u003cli\u003eSuitable for immersion, pipeline and flow-through installations\u003c\/li\u003e\n\u003cli\u003eTemperature compensation element and connection options depend on configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eReverse osmosis and purified water systems, hydroponics, water treatment and industrial process water monitoring.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eManufacturer series\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e870003-ICE-0.01 \/ 0.1 \/ 1.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement ranges (configuration dependent)\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.01–20 µS\/cm\u003cbr\u003e0–200 µS\/cm\u003cbr\u003e0–2000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResponse time\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u0026lt;60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSensor materials\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePC, 316L stainless steel, titanium alloy and platinum (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDual 3\/4-inch threads; immersion, pipeline or flow-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional NTC or Pt elements, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eManufacturer-listed dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e13 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eManufacturer-listed weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Choose one \u003e","offer_id":68312655986912,"sku":null,"price":125.0,"currency_code":"USD","in_stock":true},{"title":"0.01-20uS\/cm | 870003-ICE-0-01","offer_id":68312656019680,"sku":"870003-ICE-0-01","price":125.0,"currency_code":"USD","in_stock":true},{"title":"0-200μS\/cm | 870003-ICE-0-1","offer_id":68312656052448,"sku":"870003-ICE-0-1","price":125.0,"currency_code":"USD","in_stock":true},{"title":"0-2000μS\/cm | 870003-ICE-1-0","offer_id":68312656085216,"sku":"870003-ICE-1-0","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-conductivity-sensor-with-dual-34-inch-thread-4053321.jpg?v=1793360775"},{"product_id":"online-industrial-desulfurization-ph-sensor","title":"Online Industrial Desulfurization pH Sensor","description":"\u003ch1\u003eThis pH sensor monitors process liquids in flue gas desulfurization and industrial wastewater treatment systems.\u003c\/h1\u003e\n\u003cp\u003eA gel-filled electrode and flat glass sensing surface are designed for contaminated process liquids. The sensing surface helps resist fouling and mechanical impact, while the PPS body provides a durable housing for industrial installations. The sensor measures across a 0–14 pH range and operates at temperatures from 0 to 95 °C.\u003c\/p\u003e\n\u003cp\u003eUpper and lower 3\/4 in. NPT threads support process mounting. A direct low-noise cable provides a 5 m connection to a compatible pH analyzer. Optional 2.252 kΩ or Pt1000 temperature compensation elements can be specified to match the analyzer's input requirements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for flue gas desulfurization and wastewater pH monitoring\u003c\/li\u003e\n\u003cli\u003eFlat glass sensing surface for fouling and impact resistance\u003c\/li\u003e\n\u003cli\u003eGel-filled electrode construction\u003c\/li\u003e\n\u003cli\u003ePPS body for industrial service\u003c\/li\u003e\n\u003cli\u003eUpper and lower 3\/4 in. NPT mounting threads\u003c\/li\u003e\n\u003cli\u003e5 m low-noise cable\u003c\/li\u003e\n\u003cli\u003eOptional temperature compensation matched to the analyzer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 245.125px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 10px;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 10px;\"\u003e\u003cstrong\u003e870002-PHC8X\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e0–95 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eBody material\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003ePPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e7 pH ±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eProcess connections\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003eUpper and lower 3\/4 in. NPT threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eCable length\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003eDirect low-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 39.1875px;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 39.1875px;\"\u003e2.252 kΩ or Pt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 39.1875px;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 39.1875px;\"\u003eFlue gas desulfurization, industrial wastewater treatment and environmental water treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat applications is this sensor designed for?\u003c\/strong\u003e\u003cbr\u003eIt is intended for pH measurement in flue gas desulfurization, industrial wastewater treatment and environmental water treatment processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it connect to the process?\u003c\/strong\u003e\u003cbr\u003eThe sensor has upper and lower 3\/4 in. NPT threads and a direct 5 m low-noise cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require a pH analyzer?\u003c\/strong\u003e\u003cbr\u003eYes. Select a compatible analyzer and match the temperature compensation input to the configured sensor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68329083306208,"sku":"870002-PHC8X","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-desulfurization-ph-sensor-870002-phc8x-9020936.jpg?v=1793360773"},{"product_id":"online-industrial-pure-water-ph-and-temperature-sensor","title":"Online Industrial Pure Water pH and Temperature Sensor","description":"\u003ch1\u003eIndustrial Pure Water pH Sensor for Online Process Monitoring\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific pure water pH sensor provides online pH and temperature measurement for pure and high-purity water systems. It measures from 0 to 14 pH and 0 to 60°C, with specified accuracies of ±0.1 pH and ±0.5°C. Applications include industrial water treatment, process water monitoring and power plant water analysis.\u003c\/p\u003e\n\u003cp\u003eA polymer-filled reference system and large-area diaphragm help stabilize the junction potential in low-conductivity water. The close spacing between the reference junction and sensing glass is designed to reduce changes in diffusion potential caused by variations in flow. This supports consistent readings in demanding pure water applications.\u003c\/p\u003e\n\u003cp\u003eThe 3-in-1 electrode integrates pH measurement, temperature compensation and solution grounding. Upper and lower 3\/4 NPT threads support installation in tanks or pipelines with suitable fittings, while a directly attached low-noise cable connects the sensor to a compatible pH transmitter.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for pure and high-purity water pH monitoring\u003c\/li\u003e\n\u003cli\u003ePolymer-filled reference system with a large-area junction\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature compensation and solution grounding\u003c\/li\u003e\n\u003cli\u003eAg\/AgCl reference electrode and a slope of at least 96%\u003c\/li\u003e\n\u003cli\u003eUpper and lower 3\/4 NPT threads for flexible process installation\u003c\/li\u003e\n\u003cli\u003eLow-noise cable for connection to a compatible transmitter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSper part number\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-PHP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode slope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH 7 ±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePressure rating\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.6 MPa (6 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eInternal impedance\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤250 MΩ at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSensor design\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3-in-1 electrode with temperature compensation and solution grounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eProcess connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUpper and lower 3\/4 NPT pipe threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eDirectly attached low-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e10 kΩ, 2.252 kΩ, Pt100 or Pt1000, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eReference\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolymer-filled reference system with Ag\/AgCl electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTemperature compensation elements are available in 10 kΩ, 2.252 kΩ, Pt100 and Pt1000 configurations. Confirm the required element and cable termination for your transmitter when ordering.\u003c\/p\u003e\n\u003cp\u003eSelect a compatible pH transmitter, mounting fittings and calibration buffers for the installation. Please \u003ca href=\"https:\/\/pt2ygnm1xcw5p9lg-35682484360.shopifypreview.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e if you need assistance.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIs this sensor designed for high-purity water?\u003c\/strong\u003e\u003cbr\u003eYes. Its polymer-filled reference and large-area diaphragm are designed to support stable pH measurement in pure and high-purity water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat instrument is required to read the sensor?\u003c\/strong\u003e\u003cbr\u003eUse a compatible pH transmitter with inputs matched to the electrode and its temperature compensation element.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it installed?\u003c\/strong\u003e\u003cbr\u003eThe upper and lower 3\/4 NPT threads support tank or pipeline mounting with suitable fittings. Keep the installation within the 0–60°C temperature range and 0.6 MPa pressure rating.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68330871488736,"sku":"870002-PHP","price":137.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-pure-water-ph-and-temperature-sensor-870002-php-8075070.jpg?v=1793360767"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/Refined_wastewater_heading_on_blue_meter.png?v=1794990673","url":"https:\/\/sperdirect.com\/collections\/wastewater.oembed?page=2","provider":"Sper Scientific Direct","version":"1.0","type":"link"}