{"title":"Spectrum Analyzers","description":"\u003cdiv style=\"text-align: left;\"\u003e\u003cspan\u003e\u003cstrong\u003eSpectrum analyzers are essential tools for measuring and analyzing the frequency content of electrical and RF signals.\u003c\/strong\u003e Whether you're troubleshooting wireless communications, evaluating signal integrity, performing EMI pre-compliance testing, or designing RF circuits, a quality spectrum analyzer provides the accuracy and resolution needed to identify interference, harmonics, spurious emissions, and other signal characteristics.\u003c\/span\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan\u003eDesigned for engineers, technicians, educators, and research professionals, these instruments deliver reliable performance, intuitive operation, and advanced measurement capabilities at an exceptional value. From field service to laboratory testing, you'll find spectrum analyzers that help you diagnose problems faster and make more confident measurements.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"uts3084t-8-4-ghz-spectrum-analyzer-with-tracking-generator","title":"UTS3084T+ 8.4 GHz Spectrum Analyzer with Tracking Generator","description":"\u003ch1\u003eThe UTS3036T+ and UTS3084T+ extend spectrum coverage to 3.6 GHz and 8.4 GHz with a 40,001-point sweep engine and six traces.\u003c\/h1\u003e\n\u003cp\u003eFor RF design work above the common sub-3 GHz bands — higher-order harmonics, wideband spurious search, and signals that need fine frequency resolution across a wide span — the deeper sweep and the 8.4 GHz reach of the UTS3084T+ are the reason to choose this pair.\u003c\/p\u003e\n\u003cp\u003eTypical displayed average noise level reaches −165 dBm with the preamp on (a shared series figure for both models), phase noise is −98 dBc\/Hz typical at 10 kHz offset, and full-amplitude accuracy is under 0.7 dB. The tracking generator is built in and standard; analog demodulation, the advanced measurement kit and EMI pre-compliance are field-installable options.\u003c\/p\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive touch screen and full SCPI control over USB and LAN support scripted overnight sweeps across frequency, level and span.\u003c\/p\u003e\n\u003ch2\u003eChoosing Your Model: UTS3000T+ Performance-Series\u003c\/h2\u003e\n\u003cp\u003eThe UTS3000T+ name spans two materially different instrument classes. The four models below do not share the same sweep engine, trace count or demodulation capability — the differences go well beyond frequency reach. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout: fixed; width: 100%; height: 235.208px;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 28%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3015T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3015T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3032t-3-2-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3032T+ Spectrum Analyzer\"\u003eUTS3032T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3036t-3-6-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3036T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3036T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3084t-8-4-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3084T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3084T+\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eSweep (scan) points\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eTraces\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAnalog demodulation (option)\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eTracking generator range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e10 MHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eResolution bandwidth\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eBuilt-in tracking generator\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWithin the UTS3015T+\/UTS3032T+ class, choose by frequency reach (1.5 GHz vs 3.2 GHz). Within the UTS3036T+\/UTS3084T+ class, choose 3.6 GHz or 8.4 GHz reach. Across classes the UTS3036T+\/UTS3084T+ models add a 40,001-point sweep (4× the depth), six traces instead of four, and PM demodulation in addition to AM\/FM — confirm which class a model belongs to before assuming a shared specification.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 3.6 GHz or 8.4 GHz\u003c\/strong\u003e — 9 kHz lower edge to 3.6 GHz (UTS3036T+) or 8.4 GHz (UTS3084T+), reaching higher harmonics and wideband signals the sub-3 GHz class cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,001 sweep points, six traces\u003c\/strong\u003e — Four times the sweep depth of the entry pair, with six independent traces for simultaneous live, reference and limit comparison.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar network response on filters, amplifiers and cables; TG output to 6 GHz on the UTS3084T+.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−165 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level (10–200 MHz band) for weak-signal and low-level emissions work — a shared series figure, the same for both models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz RBW, \u0026lt; 4.8:1 shape factor\u003c\/strong\u003e — Fine resolution and selectivity for closely spaced unequal-amplitude signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise to −110 dBc\/Hz at 1 MHz\u003c\/strong\u003e — Close-in phase-noise figures suited to oscillator and synthesizer characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) for automated frequency\/level\/span sweeps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-compliance and analog demodulation options\u003c\/strong\u003e — CISPR-aware screening with quasi-peak\/EMI-average detectors; AM\/FM\/PM demodulation with SINAD and THD readout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UTS3000T+ Performance-Series Details\u003c\/h2\u003e\n\u003ch3\u003eFrequency Reach to 8.4 GHz\u003c\/h3\u003e\n\u003cp\u003eThe UTS3036T+ sweeps 9 kHz to 3.6 GHz; the UTS3084T+ to 8.4 GHz. The higher ceiling captures the third and higher harmonics of sub-3 GHz carriers and wideband spurious content that a 3 GHz-class analyzer cannot reach.\u003c\/p\u003e\n\u003ch3\u003e40,001-Point Sweep\u003c\/h3\u003e\n\u003cp\u003eEach trace carries 40,001 points — four times the entry pair — so a wide span still resolves narrow signals without sacrificing the span to keep frequency resolution. This is the practical difference when searching a multi-GHz window for a single spur.\u003c\/p\u003e\n\u003ch3\u003eSix Traces and Detector Modes\u003c\/h3\u003e\n\u003cp\u003eSix independent traces with Sample, Peak, Negative, Normal and Average detectors allow live, max-hold, reference and limit traces on screen at once — useful when comparing a measured spectrum against a stored mask.\u003c\/p\u003e\n\u003ch3\u003eSensitivity and Phase Noise\u003c\/h3\u003e\n\u003cp\u003eTypical displayed average noise level reaches −165 dBm with the preamp on (10–200 MHz band) — a shared series figure for both models. Phase noise is −98 dBc\/Hz typical at 10 kHz and reaches −110 dBc\/Hz at 1 MHz offset on the UTS3084T+, relevant when measuring a clean source close to the carrier.\u003c\/p\u003e\n\u003ch3\u003eResolution Bandwidth and Selectivity\u003c\/h3\u003e\n\u003cp\u003eRBW 1 Hz to 3 MHz in 1-3-10 steps with a \u0026lt; 4.8:1 shape factor resolves a weak product sitting next to a strong carrier.\u003c\/p\u003e\n\u003ch3\u003eReflection Measurement\u003c\/h3\u003e\n\u003cp\u003eWith the optional VSWR bridge and the built-in tracking source, the analyzer measures S11 return loss, reflection coefficient and VSWR after an Open calibration — antenna and cable verification on the same instrument.\u003c\/p\u003e\n\u003ch3\u003eEMI Pre-Compliance Screening (Option)\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit the analyzer operates as a CISPR-aware screening receiver: −6 dB resolution bandwidths of 200 Hz, 9 kHz, 120 kHz and 1 MHz; Peak, Negative-Peak, Quasi-Peak, EMI-Average and Average detectors; up to three concurrent meter traces; and editable limit-line sets for FCC, EN, MIL-STD-461, DO-160, VCCI and custom standards. A Scan \/ Search \/ Measure sequence with output report supports near-field-probe emissions screening before committing to chamber time.\u003c\/p\u003e\n\u003ch3\u003eAnalog Demodulation Analysis (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMA kit adds AM, FM and PM demodulation. Modulation rate covers 20 Hz to 100 kHz; AM depth 5–95%; FM offset 1 kHz to 400 kHz; PM phase deviation 0.2 to 6.28 rad. The result window reports modulation depth, carrier power, modulation frequency, SINAD and THD — enough to verify a transmitter's modulation quality from the same bench.\u003c\/p\u003e\n\u003ch3\u003eAdvanced One-Key Measurements (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMK kit adds channel power, power spectral density, adjacent-channel power, occupied bandwidth, transmit frequency error, zero-span (time-domain) power, carrier-to-noise ratio, third-order intercept and harmonic measurement to the 10th order, plus a spectrogram monitor — the transmitter-test set used in design verification.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eRF and Wireless Design Engineering\u003c\/h3\u003e\n\u003cp\u003eAbove 3 GHz the work is harmonic and spurious search, wideband signal characterization, and source verification. The 8.4 GHz reach of the UTS3084T+ captures the higher harmonics of a sub-3 GHz design; the 40,001-point sweep keeps narrow signals resolved across a multi-GHz span; and the close-in phase-noise figures support oscillator and synthesizer characterization. Full SCPI over LAN runs the level- and frequency-stepped sweeps a characterization report needs, unattended.\u003c\/p\u003e\n\u003ch3\u003ePre-Compliance and Multi-Function Test Benches\u003c\/h3\u003e\n\u003cp\u003eFor a lab that needs more than one instrument's worth of capability per bench, this pair consolidates spectrum analysis, scalar network response via the built-in tracking generator, reflection measurement, AM\/FM\/PM demodulation and CISPR-aware EMI screening into one instrument. Early emissions screening with a near-field probe set catches problems before chamber time; the advanced-measurement kit covers the transmitter test set for design verification — all option installs, no recurring license.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz, 100 Hz to 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelectivity (60\/3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4.8:1 (60 dB \/ 3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points \/ trace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSample, Peak, Negative, Normal, Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (typical, preamp on)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etypical displayed average noise level to -165 dBm (preamp on, 10-200 MHz band; identical for both models in that band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-95 dBc\/Hz @ 10 kHz, -98 dBc\/Hz typical; to -110 dBc\/Hz @ 1 MHz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 dB full-amplitude accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 dBm to +30 dBm, 1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreamplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 dB (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 51 dB, 1 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax safe input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V DC; \u0026lt;= +33 dBm (3 min, input attenuation \u0026gt; 20 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking generator range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz to 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTG output level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 dBm to 0 dBm, 0.5 dB resolution, +\/-3 dB flatness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReflection measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVSWR, return loss, reflection coefficient (S11); requires VSWR bridge + tracking source; excitation -20 to 0 dBm, Open calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog demod (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM, PM — UTS3036T+ 2 MHz to 3.6 GHz, UTS3084T+ 2 MHz to 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced measurement kit (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel power, power spectral density, ACP, occupied bandwidth, transmit frequency error, zero-span (T-power), CNR, TOI, harmonics (to 10th), spectrum monitor \/ spectrogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMI pre-compliance (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR RBWs 200 Hz\/9 kHz\/120 kHz\/1 MHz; Peak\/Neg-Peak\/Quasi-Peak\/EMI-Avg\/Avg detectors; editable limit lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280x800 capacitive multi-touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (USB-A), USB-Device (USB-B), LAN (VXI11) 10\/100\/1000Base RJ-45, HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull SCPI remote control over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e378 mm x 218 mm x 120 mm (W x H x L); 4.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 C to +40 C operating; -20 C to +70 C non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003cp\u003eThe tracking generator is built in on every UTS3036T+ \/ UTS3084T+ model. Field-installable options: UTS3000-AMA Analog Demodulation, UTS3000-AMK Advanced Measurement Kit, UTS3000-EMI EMI Pre-Compliance. The tracking generator is standard — it is not an added option on the T+ line.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat does the UTS3036T+\/UTS3084T+ add over the lower-frequency models in this series?\u003c\/h3\u003e\n\u003cp\u003eFrequency reach, sweep depth and trace count. The UTS3036T+ and UTS3084T+ reach 3.6 GHz and 8.4 GHz with a 40,001-point sweep and six traces; the UTS3015T+\/UTS3032T+ models reach 1.5\/3.2 GHz with a 10,001-point sweep and four traces, and their analog-demod option is AM\/FM only (no PM). The Choosing Your Model table above shows the full series comparison.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the UTS3036T+ and the UTS3084T+?\u003c\/h3\u003e\n\u003cp\u003eFrequency ceiling and tracking-generator range. The UTS3036T+ covers to 3.6 GHz with a TG to 3.6 GHz; the UTS3084T+ covers to 8.4 GHz with a TG to 6 GHz and slightly better close-in phase noise. Both share the 40,001-point sweep engine, six traces and the full option set. See \u003cem\u003eChoosing Your Model\u003c\/em\u003e above.\u003c\/p\u003e\n\u003ch3\u003eIs the tracking generator standard?\u003c\/h3\u003e\n\u003cp\u003eYes. The tracking generator is built in and standard on every UTS3000T+ model. Analog demodulation, the advanced measurement kit and EMI pre-compliance are field-installable options.\u003c\/p\u003e\n\u003ch3\u003eCan it screen for EMI before a formal compliance test?\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit it provides CISPR-bandwidth RBWs, quasi-peak and EMI-average detectors and editable limit lines (FCC, EN, MIL-STD-461, DO-160, VCCI, custom) for near-field-probe screening ahead of an accredited run.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3036T_UTS3084T_Spectrum_Analyzers_-_Data_Sheet.pdf\" title=\"UTS3036T\/UTS3084T Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T_UTS3084T Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3036T_UTS3084T_Spectrum_Analyzers_-_Data_Sheet.pdf\" title=\"UTS3036T \/ UTS3084T Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3084T+ Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T+ Users Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3084T+  Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53440746193120,"sku":"181200100033X","price":7199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/uts3084t-84-ghz-spectrum-analyzer-with-tracking-generator-181200100033x-9923984.png?v=1785534353"},{"product_id":"uts3032t-3-2-ghz-spectrum-analyzer-with-tracking-generator","title":"UTS3032T+ 3.2 GHz Spectrum Analyzer with Tracking Generator","description":"\u003ch1\u003eThe UTS3015T+ and UTS3032T+ bring 1.5 GHz and 3.2 GHz spectrum analysis, a built-in tracking generator and reflection measurement into a single bench instrument under two thousand dollars.\u003c\/h1\u003e\n\u003cp\u003eFor a small hardware team or a contract test bench, that means one box covers signal search, scalar network checks, and pre-compliance screening without three separate purchases.\u003c\/p\u003e\n\u003cp\u003eBoth models hold a typical displayed average noise level to −161 dBm (preamp on, a shared series figure), phase noise below −98 dBc\/Hz at 10 kHz offset, and full-amplitude accuracy under 0.7 dB — numbers that hold up under real measurement conditions, not peak-only figures. A 10.1-inch 1280×800 capacitive touch screen and full SCPI control over USB and LAN make the instrument scriptable from day one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTracking generator is built in\u003c\/strong\u003e on every T+ model:  and it is the defining difference of the T+ line and is standard, not an added option. Analog demodulation, the advanced measurement kit, and EMI pre-compliance remain field-installable options when a project needs them.\u003c\/p\u003e\n\u003ch2\u003eChoosing Your Model: UTS3000T+ Performance-Series\u003c\/h2\u003e\n\u003cp\u003eThe UTS3000T+ name spans two materially different instrument classes. The four models below do not share the same sweep engine, trace count or demodulation capability — the differences go well beyond frequency reach. Compare the full series before selecting:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout: fixed; width: 100%; height: 235.208px;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 28%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3015T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3015T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3032t-3-2-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3032T+ Spectrum Analyzer\"\u003eUTS3032T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3036t-3-6-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3036T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3036T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3084t-8-4-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3084T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3084T+\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eSweep (scan) points\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eTraces\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAnalog demodulation (option)\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eTracking generator range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e10 MHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eResolution bandwidth\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eBuilt-in tracking generator\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWithin the UTS3015T+\/UTS3032T+ class, choose by frequency reach (1.5 GHz vs 3.2 GHz). Within the UTS3036T+\/UTS3084T+ class, choose 3.6 GHz or 8.4 GHz reach. Across classes the UTS3036T+\/UTS3084T+ models add a 40,001-point sweep (4× the depth), six traces instead of four and PM demodulation in addition to AM\/FM — confirm which class a model belongs to before assuming a shared specification.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 1.5 GHz or 3.2 GHz\u003c\/strong\u003e — 9 kHz lower edge to a 1.5 GHz (UTS3015T+) or 3.2 GHz (UTS3032T+) upper edge, covering HF through the common sub-3 GHz ISM, IoT and wireless bands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar frequency-response and insertion-loss measurement on filters, amplifiers and cables without a separate source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge — antenna and cable checks on the same bench.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−161 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level for weak-signal work near the noise floor — a shared series figure, identical across both models at their top frequencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz resolution bandwidth\u003c\/strong\u003e — 1-3-10 steps with \u0026lt; 4.8:1 shape factor to separate closely spaced signals of unequal amplitude.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,001 sweep points, four traces\u003c\/strong\u003e — Per-trace resolution across the full span with four independent traces and five detector modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch multi-touch interface\u003c\/strong\u003e — 1280×800 capacitive screen with drag, pinch and zoom on the trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) with SCPI for scripted, repeatable test sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption-extensible\u003c\/strong\u003e — Add analog demodulation, the advanced measurement kit, or EMI pre-compliance as the work requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UTS3000T+ Performance-Series Details\u003c\/h2\u003e\n\u003ch3\u003eSpectrum Coverage and the Built-in Tracking Generator\u003c\/h3\u003e\n\u003cp\u003eThe UTS3015T+ sweeps 9 kHz to 1.5 GHz and the UTS3032T+ to 3.2 GHz. Both carry a built-in tracking generator (−40 dBm to 0 dBm output, 0.5 dB resolution), so a swept frequency-response measurement on a filter or amplifier is set up on the analyzer itself rather than wired to an external generator.\u003c\/p\u003e\n\u003ch3\u003eSensitivity for Weak-Signal Work\u003c\/h3\u003e\n\u003cp\u003eWith the preamp enabled, typical displayed average noise level reaches −161 dBm (500 kHz to 200 MHz band). This is a shared series figure — both models hold the same typical noise floor at their respective top frequencies. A low noise floor is what lets a small signal be seen rather than buried, which matters for spur hunting and low-level emissions checks.\u003c\/p\u003e\n\u003ch3\u003eResolution Bandwidth and Selectivity\u003c\/h3\u003e\n\u003cp\u003eRBW is settable from 1 Hz to 3 MHz in 1-3-10 steps. The \u0026lt; 4.8:1 (60 dB\/3 dB) shape factor resolves adjacent signals of unequal amplitude — the case where a strong carrier would otherwise mask a nearby weak product.\u003c\/p\u003e\n\u003ch3\u003e10,001-Point Sweep\u003c\/h3\u003e\n\u003cp\u003eEach trace carries 10,001 points across the selected span, giving the frequency resolution needed to catch narrow signals that a coarser sweep would step over.\u003c\/p\u003e\n\u003ch3\u003eReflection Measurement\u003c\/h3\u003e\n\u003cp\u003eWith the optional VSWR bridge and the built-in tracking source, the analyzer measures S11 return loss, reflection coefficient and VSWR. After an Open calibration, a marker on the trace reads the value at any frequency — enough for antenna tuning and cable-fault checks without a dedicated VNA.\u003c\/p\u003e\n\u003ch3\u003e10.1-inch Multi-Touch Operation\u003c\/h3\u003e\n\u003cp\u003eThe 1280×800 capacitive screen supports drag, expand and zoom directly on the trace, with a fixed menu layout that keeps common settings one or two presses away.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eContract Test Labs and Design Consultancies\u003c\/h3\u003e\n\u003cp\u003eFor a single-digit-engineer shop, bench space and budget are both finite. One UTS3015T+ or UTS3032T+ covers signal search, scalar network response with the built-in tracking generator, return-loss checks with the reflection-measurement bridge, and — with the EMI option — early conducted\/radiated screening before a formal CISPR run. SCPI over LAN drops it straight into a Python or LabVIEW acceptance-test procedure. No per-feature license conversations: the options are one-time installs, not recurring fees.\u003c\/p\u003e\n\u003ch3\u003eBench RF Design and Validation\u003c\/h3\u003e\n\u003cp\u003eOn a design bench, the same instrument verifies oscillator output, checks harmonic and spurious content against a target, characterizes a filter or matching network with the tracking generator, and confirms antenna match with the VSWR bridge. The \u0026lt; 0.7 dB full-amplitude accuracy and −161 dBm typical DANL mean the numbers used in a design-verification report hold up under the conditions they were measured in.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 3.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz, 100 Hz to 3.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelectivity (60\/3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4.8:1 (60 dB \/ 3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points \/ trace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSample, Peak, Negative, Normal, Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (typical, preamp on)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etypical displayed average noise level to -161 dBm (preamp on, 500 kHz-200 MHz band; identical at each model's top frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; -98 dBc\/Hz @ 10 kHz offset (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 dB full-amplitude accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 dBm to +30 dBm, 1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreamplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 dB (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 51 dB, 1 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax safe input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V DC; \u0026lt;= +33 dBm (3 min, input attenuation \u0026gt; 20 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking generator range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz to 3.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTG output level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 dBm to 0 dBm, 0.5 dB resolution, +\/-3 dB flatness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReflection measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVSWR, return loss, reflection coefficient (S11); requires VSWR bridge + tracking source; excitation -20 to 0 dBm, Open calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog demod (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM — UTS3015T+ 2 MHz to 1.5 GHz, UTS3032T+ 2 MHz to 3.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced measurement kit (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel power, power spectral density, ACP, occupied bandwidth, transmit frequency error, zero-span (T-power), CNR, TOI, harmonics (to 10th), spectrum monitor \/ spectrogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMI pre-compliance (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR RBWs 200 Hz\/9 kHz\/120 kHz\/1 MHz; Peak\/Neg-Peak\/Quasi-Peak\/EMI-Avg\/Avg detectors; editable limit lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280x800 capacitive multi-touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (USB-A), USB-Device (USB-B), LAN (VXI11) 10\/100\/1000Base RJ-45, HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull SCPI remote control over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e378 mm x 218 mm x 120 mm (W x H x L); 4.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 C to +40 C operating; -20 C to +70 C non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h4\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories and Family Options\u003c\/h3\u003e\n\u003cp\u003eThe tracking generator is built in on every UTS3015T+ \/ UTS3032T+ model. Field-installable options: UTS3000-AMA Analog Demodulation, UTS3000-AMK Advanced Measurement Kit, UTS3000-EMI EMI Pre-Compliance. The tracking generator is standard — it is not an added option on the T+ line.\u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eDoes the tracking generator cost extra on the T+?\u003c\/h3\u003e\n\u003cp\u003eNo. The tracking generator is built in and standard on every UTS3000T+ model, including the UTS3015T+ and UTS3032T+. It is the defining feature of the T+ line.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the UTS3015T+ and the UTS3032T+?\u003c\/h3\u003e\n\u003cp\u003eFrequency reach and sensitivity. The UTS3015T+ covers 9 kHz to 1.5 GHz; the UTS3032T+ covers 9 kHz to 3.2 GHz. Both models share the same typical noise floor at their top frequencies, plus the same 10,001-point sweep engine, four traces, RBW range, touch interface and built-in tracking generator. The difference is frequency reach: 1.5 GHz versus 3.2 GHz. See \u003cem\u003eChoosing Your Model\u003c\/em\u003e above.\u003c\/p\u003e\n\u003ch3\u003eCan it do EMI pre-compliance?\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit, yes. It adds CISPR-bandwidth RBWs (200 Hz, 9 kHz, 120 kHz, 1 MHz), quasi-peak and EMI-average detectors and editable limit lines for screening with a near-field probe set before a formal compliance run.\u003c\/p\u003e\n\u003ch3\u003eHow is it controlled remotely?\u003c\/h3\u003e\n\u003cp\u003eFull SCPI over USB or LAN (VXI11). It integrates with Python, LabVIEW and MATLAB through standard VISA.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3015T_UTS3032T_Datasheet.pdf\" title=\"UTS3015T\/UTS3032T Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T_UTS3084T Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3015T_UTS3032T_Datasheet.pdf\" title=\"UTS3015T \/ UTS3032T Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3032T+ Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T+ Users Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3032T+  Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53440746225888,"sku":"181200100034X","price":1699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/uts3032t-32-ghz-spectrum-analyzer-with-tracking-generator-181200100034x-8947527.png?v=1785534352"},{"product_id":"uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator","title":"UTS3015T+ 1.5 GHz Spectrum Analyzer with Tracking Generator","description":"\u003ch1\u003eThe UTS3015T+ and UTS3032T+ bring 1.5 GHz and 3.2 GHz spectrum analysis, a built-in tracking generator, and reflection measurement into a single bench instrument under two thousand dollars.\u003c\/h1\u003e\n\u003cp\u003eFor a small hardware team or a contract test bench, that means one box covers signal search, scalar network checks, and pre-compliance screening without three separate purchases.\u003c\/p\u003e\n\u003cp\u003eBoth models hold a typical displayed average noise level to −161 dBm (preamp on, a shared series figure), phase noise below −98 dBc\/Hz at 10 kHz offset, and full-amplitude accuracy under 0.7 dB — numbers that hold up under real measurement conditions, not peak-only figures. A 10.1-inch 1280×800 capacitive touch screen and full SCPI control over USB and LAN make the instrument scriptable from day one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTracking generator is built in\u003c\/strong\u003e on every T+ model — it is the defining difference of the T+ line and is standard, not an added option. Analog demodulation, the advanced measurement kit, and EMI pre-compliance remain field-installable options when a project needs them.\u003c\/p\u003e\n\u003ch2\u003eChoosing Your Model: UTS3000T+ Performance-Series\u003c\/h2\u003e\n\u003cp\u003eThe UTS3000T+ name spans two materially different instrument classes. The four models below do not share the same sweep engine, trace count or demodulation capability — the differences go well beyond frequency reach. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout: fixed; width: 100%; height: 235.208px;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 28%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3015T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3015T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3032t-3-2-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3032T+ Spectrum Analyzer\"\u003eUTS3032T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3036t-3-6-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3036T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3036T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3084t-8-4-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3084T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3084T+\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eSweep (scan) points\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eTraces\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAnalog demodulation (option)\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eTracking generator range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e10 MHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eResolution bandwidth\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eBuilt-in tracking generator\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWithin the UTS3015T+\/UTS3032T+ class, choose by frequency reach (1.5 GHz vs 3.2 GHz). Within the UTS3036T+\/UTS3084T+ class, choose 3.6 GHz or 8.4 GHz reach. Across classes the UTS3036T+\/UTS3084T+ models add a 40,001-point sweep (4× the depth), six traces instead of four, and PM demodulation in addition to AM\/FM — confirm which class a model belongs to before assuming a shared specification.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 3.6 GHz or 8.4 GHz\u003c\/strong\u003e — 9 kHz lower edge to 3.6 GHz (UTS3036T+) or 8.4 GHz (UTS3084T+), reaching higher harmonics and wideband signals the sub-3 GHz class cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,001 sweep points, six traces\u003c\/strong\u003e — Four times the sweep depth of the entry pair, with six independent traces for simultaneous live, reference and limit comparison.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar network response on filters, amplifiers and cables; TG output to 6 GHz on the UTS3084T+.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−165 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level (10–200 MHz band) for weak-signal and low-level emissions work — a shared series figure, the same for both models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz RBW, \u0026lt; 4.8:1 shape factor\u003c\/strong\u003e — Fine resolution and selectivity for closely spaced unequal-amplitude signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise to −110 dBc\/Hz at 1 MHz\u003c\/strong\u003e — Close-in phase-noise figures suited to oscillator and synthesizer characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) for automated frequency\/level\/span sweeps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-compliance and analog demodulation options\u003c\/strong\u003e — CISPR-aware screening with quasi-peak\/EMI-average detectors; AM\/FM\/PM demodulation with SINAD and THD readout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UTS3000T+ Performance-Series Details\u003c\/h2\u003e\n\u003ch3\u003eFrequency Reach to 8.4 GHz\u003c\/h3\u003e\n\u003cp\u003eThe UTS3036T+ sweeps 9 kHz to 3.6 GHz; the UTS3084T+ to 8.4 GHz. The higher ceiling captures the third and higher harmonics of sub-3 GHz carriers and wideband spurious content that a 3 GHz-class analyzer cannot reach.\u003c\/p\u003e\n\u003ch3\u003e40,001-Point Sweep\u003c\/h3\u003e\n\u003cp\u003eEach trace carries 40,001 points — four times the entry pair — so a wide span still resolves narrow signals without sacrificing the span to keep frequency resolution. This is the practical difference when searching a multi-GHz window for a single spur.\u003c\/p\u003e\n\u003ch3\u003eSix Traces and Detector Modes\u003c\/h3\u003e\n\u003cp\u003eSix independent traces with Sample, Peak, Negative, Normal and Average detectors allow live, max-hold, reference and limit traces on screen at once — useful when comparing a measured spectrum against a stored mask.\u003c\/p\u003e\n\u003ch3\u003eSensitivity and Phase Noise\u003c\/h3\u003e\n\u003cp\u003eTypical displayed average noise level reaches −165 dBm with the preamp on (10–200 MHz band) — a shared series figure for both models. Phase noise is −98 dBc\/Hz typical at 10 kHz and reaches −110 dBc\/Hz at 1 MHz offset on the UTS3084T+, relevant when measuring a clean source close to the carrier.\u003c\/p\u003e\n\u003ch3\u003eReflection Measurement\u003c\/h3\u003e\n\u003cp\u003eWith the optional VSWR bridge and the built-in tracking source, the analyzer measures S11 return loss, reflection coefficient and VSWR after an Open calibration — antenna and cable verification on the same instrument.\u003c\/p\u003e\n\u003ch3\u003eEMI Pre-Compliance Screening (Option)\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit the analyzer operates as a CISPR-aware screening receiver: −6 dB resolution bandwidths of 200 Hz, 9 kHz, 120 kHz and 1 MHz; Peak, Negative-Peak, Quasi-Peak, EMI-Average and Average detectors; up to three concurrent meter traces; and editable limit-line sets for FCC, EN, MIL-STD-461, DO-160, VCCI and custom standards. A Scan \/ Search \/ Measure sequence with output report supports near-field-probe emissions screening before committing to chamber time.\u003c\/p\u003e\n\u003ch3\u003eAnalog Demodulation Analysis (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMA kit adds AM, FM and PM demodulation. Modulation rate covers 20 Hz to 100 kHz; AM depth 5–95%; FM offset 1 kHz to 400 kHz; PM phase deviation 0.2 to 6.28 rad. The result window reports modulation depth, carrier power, modulation frequency, SINAD and THD — enough to verify a transmitter's modulation quality from the same bench.\u003c\/p\u003e\n\u003ch3\u003eAdvanced One-Key Measurements (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMK kit adds channel power, power spectral density, adjacent-channel power, occupied bandwidth, transmit frequency error, zero-span (time-domain) power, carrier-to-noise ratio, third-order intercept and harmonic measurement to the 10th order, plus a spectrogram monitor — the transmitter-test set used in design verification.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eRF and Wireless Design Engineering\u003c\/h3\u003e\n\u003cp\u003eAbove 3 GHz the work is harmonic and spurious search, wideband signal characterization, and source verification. The 8.4 GHz reach of the UTS3084T+ captures the higher harmonics of a sub-3 GHz design; the 40,001-point sweep keeps narrow signals resolved across a multi-GHz span; and the close-in phase-noise figures support oscillator and synthesizer characterization. Full SCPI over LAN runs the level- and frequency-stepped sweeps a characterization report needs, unattended.\u003c\/p\u003e\n\u003ch3\u003ePre-Compliance and Multi-Function Test Benches\u003c\/h3\u003e\n\u003cp\u003eFor a lab that needs more than one instrument's worth of capability per bench, this pair consolidates spectrum analysis, scalar network response via the built-in tracking generator, reflection measurement, AM\/FM\/PM demodulation and CISPR-aware EMI screening into one instrument. Early emissions screening with a near-field probe set catches problems before chamber time; the advanced-measurement kit covers the transmitter test set for design verification — all option installs, no recurring license.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 1.5 GHz or 3.2 GHz\u003c\/strong\u003e — 9 kHz lower edge to a 1.5 GHz (UTS3015T+) or 3.2 GHz (UTS3032T+) upper edge, covering HF through the common sub-3 GHz ISM, IoT and wireless bands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar frequency-response and insertion-loss measurement on filters, amplifiers and cables without a separate source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge — antenna and cable checks on the same bench.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−161 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level for weak-signal work near the noise floor — a shared series figure, identical across both models at their top frequencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz resolution bandwidth\u003c\/strong\u003e — 1-3-10 steps with \u0026lt; 4.8:1 shape factor to separate closely spaced signals of unequal amplitude.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,001 sweep points, four traces\u003c\/strong\u003e — Per-trace resolution across the full span with four independent traces and five detector modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch multi-touch interface\u003c\/strong\u003e — 1280×800 capacitive screen with drag, pinch and zoom on the trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) with SCPI for scripted, repeatable test sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption-extensible\u003c\/strong\u003e — Add analog demodulation, the advanced measurement kit, or EMI pre-compliance as the work requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 1.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz, 100 Hz to 1.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelectivity (60\/3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4.8:1 (60 dB \/ 3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points \/ trace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSample, Peak, Negative, Normal, Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (typical, preamp on)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etypical displayed average noise level to -161 dBm (preamp on, 500 kHz-200 MHz band; identical at each model's top frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; -98 dBc\/Hz @ 10 kHz offset (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 dB full-amplitude accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 dBm to +30 dBm, 1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreamplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 dB (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 51 dB, 1 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax safe input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V DC; \u0026lt;= +33 dBm (3 min, input attenuation \u0026gt; 20 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking generator range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz to 1.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTG output level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 dBm to 0 dBm, 0.5 dB resolution, +\/-3 dB flatness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReflection measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVSWR, return loss, reflection coefficient (S11); requires VSWR bridge + tracking source; excitation -20 to 0 dBm, Open calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog demod (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM — UTS3015T+ 2 MHz to 1.5 GHz, UTS3032T+ 2 MHz to 3.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced measurement kit (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel power, power spectral density, ACP, occupied bandwidth, transmit frequency error, zero-span (T-power), CNR, TOI, harmonics (to 10th), spectrum monitor \/ spectrogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMI pre-compliance (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR RBWs 200 Hz\/9 kHz\/120 kHz\/1 MHz; Peak\/Neg-Peak\/Quasi-Peak\/EMI-Avg\/Avg detectors; editable limit lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280x800 capacitive multi-touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (USB-A), USB-Device (USB-B), LAN (VXI11) 10\/100\/1000Base RJ-45, HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull SCPI remote control over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e378 mm x 218 mm x 120 mm (W x H x L); 4.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 C to +40 C operating; -20 C to +70 C non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories and Family Options\u003c\/h3\u003e\n\u003cp\u003eThe tracking generator is built in on every UTS3036T+ \/ UTS3084T+ model. Field-installable options: UTS3000-AMA Analog Demodulation, UTS3000-AMK Advanced Measurement Kit, UTS3000-EMI EMI Pre-Compliance. The tracking generator is standard — it is not an added option on the T+ line.\u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eDoes the tracking generator cost extra on the T+?\u003c\/h3\u003e\n\u003cp\u003eNo. The tracking generator is built in and standard on every UTS3000T+ model, including the UTS3015T+ and UTS3032T+. It is the defining feature of the T+ line.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the UTS3015T+ and the UTS3032T+?\u003c\/h3\u003e\n\u003cp\u003eFrequency reach and sensitivity. The UTS3015T+ covers 9 kHz to 1.5 GHz; the UTS3032T+ covers 9 kHz to 3.2 GHz. Both models share the same typical noise floor at their top frequencies, plus the same 10,001-point sweep engine, four traces, RBW range, touch interface and built-in tracking generator. The difference is frequency reach: 1.5 GHz versus 3.2 GHz. See \u003cem\u003eChoosing Your Model\u003c\/em\u003e above.\u003c\/p\u003e\n\u003ch3\u003eCan it do EMI pre-compliance?\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit, yes. It adds CISPR-bandwidth RBWs (200 Hz, 9 kHz, 120 kHz, 1 MHz), quasi-peak and EMI-average detectors and editable limit lines for screening with a near-field probe set before a formal compliance run.\u003c\/p\u003e\n\u003ch3\u003eHow is it controlled remotely?\u003c\/h3\u003e\n\u003cp\u003eFull SCPI over USB or LAN (VXI11). It integrates with Python, LabVIEW and MATLAB through standard VISA.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3015T_UTS3032T_Datasheet.pdf\" target=\"_blank\" title=\"UTS3015T\/UTS3032T Datasheet\" rel=\"noopener\"\u003e\u003cimg alt=\"UTS3036T_UTS3084T Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3015T_UTS3032T_Datasheet.pdf\" target=\"_blank\" title=\"UTS3015T \/ UTS3032T Datasheet\" rel=\"noopener\"\u003eUNI-T UTS3015T+ Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T+ Users Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3084T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3015T+  Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53440746258656,"sku":"181200100035X","price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/uts3015t-15-ghz-spectrum-analyzer-with-tracking-generator-181200100035x-7949284.png?v=1785534351"},{"product_id":"uts3036t-3-6-ghz-spectrum-analyzer-with-tracking-generator","title":"UTS3036T+ 3.6 GHz Spectrum Analyzer with Tracking Generator","description":"\u003ch1\u003eThe UTS3036T+ and UTS3084T+ extend spectrum coverage to 3.6 GHz and 8.4 GHz with a 40,001-point sweep engine and six traces.\u003c\/h1\u003e\n\u003cp\u003eFor RF design work above the common sub-3 GHz bands — higher-order harmonics, wideband spurious search, and signals that need fine frequency resolution across a wide span — the deeper sweep and the 8.4 GHz reach of the UTS3084T+ are the reason to choose this pair.\u003c\/p\u003e\n\u003cp\u003eTypical displayed average noise level reaches −165 dBm with the preamp on (a shared series figure for both models), phase noise is −98 dBc\/Hz typical at 10 kHz offset, and full-amplitude accuracy is under 0.7 dB. The tracking generator is built in and standard; analog demodulation, the advanced measurement kit and EMI pre-compliance are field-installable options.\u003c\/p\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive touch screen and full SCPI control over USB and LAN support scripted overnight sweeps across frequency, level and span.\u003c\/p\u003e\n\u003ch2\u003eChoosing Your Model: UTS3000T+ Performance-Series\u003c\/h2\u003e\n\u003cp\u003eThe UTS3000T+ name spans two materially different instrument classes. The four models below do not share the same sweep engine, trace count or demodulation capability — the differences go well beyond frequency reach. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout: fixed; width: 100%; height: 235.208px;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 28%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3015t-1-5-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3015T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3015T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3032t-3-2-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3032T+ Spectrum Analyzer\"\u003eUTS3032T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3036t-3-6-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3036T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3036T+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth style=\"height: 19.6007px;\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/spectrum-analyzers\/products\/uts3084t-8-4-ghz-spectrum-analyzer-with-tracking-generator\" title=\"UTS3084T+ Spectrum Analyzer\" rel=\"noopener\" target=\"_blank\"\u003eUTS3084T+\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e9 kHz – 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eSweep (scan) points\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e10,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eTraces\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAnalog demodulation (option)\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eAM, FM, PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eTracking generator range\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 1.5 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e10 MHz – 3.2 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 3.6 GHz\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003e100 kHz – 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003eResolution bandwidth\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003ctd style=\"height: 19.6007px;\"\u003e1 Hz – 3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eBuilt-in tracking generator\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"height: 39.2014px;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWithin the UTS3015T+\/UTS3032T+ class, choose by frequency reach (1.5 GHz vs 3.2 GHz). Within the UTS3036T+\/UTS3084T+ class, choose 3.6 GHz or 8.4 GHz reach. Across classes the UTS3036T+\/UTS3084T+ models add a 40,001-point sweep (4× the depth), six traces instead of four, and PM demodulation in addition to AM\/FM — confirm which class a model belongs to before assuming a shared specification.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum analysis to 3.6 GHz or 8.4 GHz\u003c\/strong\u003e — 9 kHz lower edge to 3.6 GHz (UTS3036T+) or 8.4 GHz (UTS3084T+), reaching higher harmonics and wideband signals the sub-3 GHz class cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,001 sweep points, six traces\u003c\/strong\u003e — Four times the sweep depth of the entry pair, with six independent traces for simultaneous live, reference and limit comparison.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in tracking generator\u003c\/strong\u003e — Standard on both models — scalar network response on filters, amplifiers and cables; TG output to 6 GHz on the UTS3084T+.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−165 dBm typical DANL (preamp on)\u003c\/strong\u003e — Low displayed average noise level (10–200 MHz band) for weak-signal and low-level emissions work — a shared series figure, the same for both models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReflection measurement (S11)\u003c\/strong\u003e — Return loss, VSWR and reflection coefficient with the optional VSWR bridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Hz to 3 MHz RBW, \u0026lt; 4.8:1 shape factor\u003c\/strong\u003e — Fine resolution and selectivity for closely spaced unequal-amplitude signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise to −110 dBc\/Hz at 1 MHz\u003c\/strong\u003e — Close-in phase-noise figures suited to oscillator and synthesizer characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI remote control\u003c\/strong\u003e — USB and LAN (VXI11) for automated frequency\/level\/span sweeps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-compliance and analog demodulation options\u003c\/strong\u003e — CISPR-aware screening with quasi-peak\/EMI-average detectors; AM\/FM\/PM demodulation with SINAD and THD readout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T UTS3000T+ Performance-Series Details\u003c\/h2\u003e\n\u003ch3\u003eFrequency Reach to 8.4 GHz\u003c\/h3\u003e\n\u003cp\u003eThe UTS3036T+ sweeps 9 kHz to 3.6 GHz; the UTS3084T+ to 8.4 GHz. The higher ceiling captures the third and higher harmonics of sub-3 GHz carriers and wideband spurious content that a 3 GHz-class analyzer cannot reach.\u003c\/p\u003e\n\u003ch3\u003e40,001-Point Sweep\u003c\/h3\u003e\n\u003cp\u003eEach trace carries 40,001 points — four times the entry pair — so a wide span still resolves narrow signals without sacrificing the span to keep frequency resolution. This is the practical difference when searching a multi-GHz window for a single spur.\u003c\/p\u003e\n\u003ch3\u003eSix Traces and Detector Modes\u003c\/h3\u003e\n\u003cp\u003eSix independent traces with Sample, Peak, Negative, Normal and Average detectors allow live, max-hold, reference and limit traces on screen at once — useful when comparing a measured spectrum against a stored mask.\u003c\/p\u003e\n\u003ch3\u003eSensitivity and Phase Noise\u003c\/h3\u003e\n\u003cp\u003eTypical displayed average noise level reaches −165 dBm with the preamp on (10–200 MHz band) — a shared series figure for both models. Phase noise is −98 dBc\/Hz typical at 10 kHz and reaches −110 dBc\/Hz at 1 MHz offset on the UTS3084T+, relevant when measuring a clean source close to the carrier.\u003c\/p\u003e\n\u003ch3\u003eReflection Measurement\u003c\/h3\u003e\n\u003cp\u003eWith the optional VSWR bridge and the built-in tracking source, the analyzer measures S11 return loss, reflection coefficient and VSWR after an Open calibration — antenna and cable verification on the same instrument.\u003c\/p\u003e\n\u003ch3\u003eEMI Pre-Compliance Screening (Option)\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit the analyzer operates as a CISPR-aware screening receiver: −6 dB resolution bandwidths of 200 Hz, 9 kHz, 120 kHz and 1 MHz; Peak, Negative-Peak, Quasi-Peak, EMI-Average and Average detectors; up to three concurrent meter traces; and editable limit-line sets for FCC, EN, MIL-STD-461, DO-160, VCCI and custom standards. A Scan \/ Search \/ Measure sequence with output report supports near-field-probe emissions screening before committing to chamber time.\u003c\/p\u003e\n\u003ch3\u003eAnalog Demodulation Analysis (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMA kit adds AM, FM and PM demodulation. Modulation rate covers 20 Hz to 100 kHz; AM depth 5–95%; FM offset 1 kHz to 400 kHz; PM phase deviation 0.2 to 6.28 rad. The result window reports modulation depth, carrier power, modulation frequency, SINAD and THD — enough to verify a transmitter's modulation quality from the same bench.\u003c\/p\u003e\n\u003ch3\u003eAdvanced One-Key Measurements (Option)\u003c\/h3\u003e\n\u003cp\u003eThe optional UTS3000-AMK kit adds channel power, power spectral density, adjacent-channel power, occupied bandwidth, transmit frequency error, zero-span (time-domain) power, carrier-to-noise ratio, third-order intercept and harmonic measurement to the 10th order, plus a spectrogram monitor — the transmitter-test set used in design verification.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eRF and Wireless Design Engineering\u003c\/h3\u003e\n\u003cp\u003eAbove 3 GHz the work is harmonic and spurious search, wideband signal characterization, and source verification. The 8.4 GHz reach of the UTS3084T+ captures the higher harmonics of a sub-3 GHz design; the 40,001-point sweep keeps narrow signals resolved across a multi-GHz span; and the close-in phase-noise figures support oscillator and synthesizer characterization. Full SCPI over LAN runs the level- and frequency-stepped sweeps a characterization report needs, unattended.\u003c\/p\u003e\n\u003ch3\u003ePre-Compliance and Multi-Function Test Benches\u003c\/h3\u003e\n\u003cp\u003eFor a lab that needs more than one instrument's worth of capability per bench, this pair consolidates spectrum analysis, scalar network response via the built-in tracking generator, reflection measurement, AM\/FM\/PM demodulation and CISPR-aware EMI screening into one instrument. Early emissions screening with a near-field probe set catches problems before chamber time; the advanced-measurement kit covers the transmitter test set for design verification — all option installs, no recurring license.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 3.6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz, 100 Hz to 3.6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz, 1-3-10 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelectivity (60\/3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4.8:1 (60 dB \/ 3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points \/ trace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSample, Peak, Negative, Normal, Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (typical, preamp on)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etypical displayed average noise level to -165 dBm (preamp on, 10-200 MHz band; identical for both models in that band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-95 dBc\/Hz @ 10 kHz, -98 dBc\/Hz typical; to -110 dBc\/Hz @ 1 MHz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 dB full-amplitude accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 dBm to +30 dBm, 1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreamplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 dB (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 51 dB, 1 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax safe input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V DC; \u0026lt;= +33 dBm (3 min, input attenuation \u0026gt; 20 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking generator range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz to 3.6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTG output level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 dBm to 0 dBm, 0.5 dB resolution, +\/-3 dB flatness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReflection measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVSWR, return loss, reflection coefficient (S11); requires VSWR bridge + tracking source; excitation -20 to 0 dBm, Open calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog demod (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM, PM — UTS3036T+ 2 MHz to 3.6 GHz, UTS3084T+ 2 MHz to 8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced measurement kit (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel power, power spectral density, ACP, occupied bandwidth, transmit frequency error, zero-span (T-power), CNR, TOI, harmonics (to 10th), spectrum monitor \/ spectrogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMI pre-compliance (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCISPR RBWs 200 Hz\/9 kHz\/120 kHz\/1 MHz; Peak\/Neg-Peak\/Quasi-Peak\/EMI-Avg\/Avg detectors; editable limit lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280x800 capacitive multi-touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (USB-A), USB-Device (USB-B), LAN (VXI11) 10\/100\/1000Base RJ-45, HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull SCPI remote control over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e378 mm x 218 mm x 120 mm (W x H x L); 4.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 C to +40 C operating; -20 C to +70 C non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories and Family Options\u003c\/h3\u003e\n\u003cp\u003eThe tracking generator is built in on every UTS3036T+ \/ UTS3084T+ model. Field-installable options: UTS3000-AMA Analog Demodulation, UTS3000-AMK Advanced Measurement Kit, UTS3000-EMI EMI Pre-Compliance. The tracking generator is standard — it is not an added option on the T+ line.\u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat does the UTS3036T+\/UTS3084T+ add over the lower-frequency models in this series?\u003c\/h3\u003e\n\u003cp\u003eFrequency reach, sweep depth and trace count. The UTS3036T+ and UTS3084T+ reach 3.6 GHz and 8.4 GHz with a 40,001-point sweep and six traces; the UTS3015T+\/UTS3032T+ models reach 1.5\/3.2 GHz with a 10,001-point sweep and four traces, and their analog-demod option is AM\/FM only (no PM). The Choosing Your Model table above shows the full series comparison.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the UTS3036T+ and the UTS3084T+?\u003c\/h3\u003e\n\u003cp\u003eFrequency ceiling and tracking-generator range. The UTS3036T+ covers to 3.6 GHz with a TG to 3.6 GHz; the UTS3084T+ covers to 8.4 GHz with a TG to 6 GHz and slightly better close-in phase noise. Both share the 40,001-point sweep engine, six traces and the full option set. See \u003cem\u003eChoosing Your Model\u003c\/em\u003e above.\u003c\/p\u003e\n\u003ch3\u003eIs the tracking generator standard?\u003c\/h3\u003e\n\u003cp\u003eYes. The tracking generator is built in and standard on every UTS3000T+ model. Analog demodulation, the advanced measurement kit and EMI pre-compliance are field-installable options.\u003c\/p\u003e\n\u003ch3\u003eCan it screen for EMI before a formal compliance test?\u003c\/h3\u003e\n\u003cp\u003eWith the optional UTS3000-EMI kit it provides CISPR-bandwidth RBWs, quasi-peak and EMI-average detectors and editable limit lines (FCC, EN, MIL-STD-461, DO-160, VCCI, custom) for near-field-probe screening ahead of an accredited run.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3036T_UTS3084T_Spectrum_Analyzers_-_Data_Sheet.pdf\" title=\"UTS3036T\/UTS3084T Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T_UTS3084T Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3036T_UTS3084T_Spectrum_Analyzers_-_Data_Sheet.pdf\" title=\"UTS3036T \/ UTS3084T Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3036T+ Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3036T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"UTS3036T+ Users Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"margin-bottom: 16px; float: left;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UN I-T UPO1000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf?v=1782929043\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UTS3000T_User_Manual.pdf\" title=\"UTS3036T+ Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UTS3036T+  Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53440746291424,"sku":"181200100036X","price":2899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/uts3036t-36-ghz-spectrum-analyzer-with-tracking-generator-181200100036x-1890877.png?v=1785534351"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/spectrum-analyzers-7006509.png?v=1785534132","url":"https:\/\/sperdirect.com\/collections\/spectrum-analyzers.oembed","provider":"Sper Scientific Direct","version":"1.0","type":"link"}