{"title":"Pharmaceuticals","description":"\u003cp\u003e\u003cstrong\u003ePharmaceutical testing and process monitoring depend on measurements suited to the material, process and working environment.\u003c\/strong\u003e Instruments for water quality, laboratory analysis and bioprocess monitoring help teams collect the information they need throughout development and production.\u003c\/p\u003e\u003cp\u003eExplore sensors, meters and laboratory instruments for pharmaceutical applications. Check measurement ranges, material compatibility and installation requirements when selecting equipment for your process.\u003c\/p\u003e","products":[{"product_id":"industrial-dissolved-oxygen-meter","title":"Online Industrial Dissolved Oxygen Meter","description":"\u003ch1\u003eInline Dissolved Oxygen Analyzer is designed for continuous, real-time DO monitoring across a wide range of industrial processes.\u003c\/h1\u003e\n\u003cp\u003eBuilt with a rugged yet straightforward design, the industrial dissolved oxygen probes deliver precise measurements in any process condition. Ideal for industries like pharmaceuticals, food and beverage, chemicals, power, microelectronics and clean water applications, this system ensures reliable dissolved oxygen monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient and easy-to-service dissolved oxygen measurement\u003c\/li\u003e\n\u003cli\u003eMeasures dissolved oxygen levels from ppb to ppm\u003c\/li\u003e\n\u003cli\u003eFast response time, even at ppb levels\u003c\/li\u003e\n\u003cli\u003eDurable, hygienic design for continuous online monitoring\u003c\/li\u003e\n\u003cli\u003eUser-friendly operation with an intuitive interface\u003c\/li\u003e\n\u003cli\u003eLower overall cost per measurement point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper #870007 Dissolved Oxygen Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"272\" colspan=\"2\" rowspan=\"1\"\u003e\u003cspan\u003eDissolved Oxygen, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDO Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\" width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\n\u003cp\u003e0.00~20.00 ug\/L \u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~20.00 mg\/L \u003c\/p\u003e\n\u003cp\u003e0.00%~200.00 % \u003c\/p\u003e\n\u003cp\u003e-10.0℃~130.0℃ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" colspan=\"1\" rowspan=\"1\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant: V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" rowspan=\"1\" colspan=\"1\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays, 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K \/ 22K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"79\" rowspan=\"1\" colspan=\"1\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"79\" rowspan=\"1\" colspan=\"1\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870007_Industrial_DO_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870007_Industrial_DO_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435455200,"sku":"870007","price":825.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-optical-dissolved-oxygen-meter-870006-203770.jpg?v=1752691908"},{"product_id":"spsv5100-spsuv-5100-visible-light-spectrophotometer","title":"SPSV-5100\/SPSUV-5100 Visible UV-Vis Spectrophotometer","description":"\u003ch1\u003eHigh-Performance Visible \u0026amp; UV-Visible Spectrophotometers for Reliable and Accurate Analysis\u003c\/h1\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Free_Shipping4_160x160.png\" alt=\"FREE SHIPPING\" style=\"float: right;\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe SPSV-5100 and SPSUV-5100 are advanced spectrophotometers designed for precise absorbance and transmittance measurement across various laboratory applications. Featuring a clear 2.5-inch LCD display, high-stability Tungsten and Deuterium lamps and user-friendly controls, these instruments are ideal for rapid quantitative analysis using standard curves.\u003c\/p\u003e\n\u003cp\u003eWhether you're measuring in the visible range (SPSV-5100) or the UV-visible spectrum (SPSUV-5100), both models deliver high photometric accuracy, intuitive operation and efficient data management through USB and parallel port outputs. \u003cstrong\u003eAll units are calibrated and include a factory calibration report.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2.5\" High-Definition LCD Display\u003c\/strong\u003e\u003cbr\u003eView real-time standard curves and results with clarity and precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDual High-Quality Light Sources\u003c\/strong\u003e\u003cbr\u003eTungsten and Deuterium lamps provide low stray light, stable readings and extended service life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Standard Curve Setup\u003c\/strong\u003e\u003cbr\u003eEstablish standard curves quickly and perform fast analysis of unknown samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUSB \u0026amp; Parallel Data Output\u003c\/strong\u003e\u003cbr\u003eUSB port: Connect to PC (optional software required).\u003cbr\u003eParallel port: Connect to optional micro thermal printer for direct printouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarge Data Storage\u003c\/strong\u003e\u003cbr\u003eDisplay up to 5 readings per screen (wavelength, absorbance, transmittance).\u003cbr\u003eSave up to 200 test result sets internally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Wavelength Adjustment\u003c\/strong\u003e\u003cbr\u003eSet the measurement wavelength quickly using arrow keys—reduces user error and setup time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight and Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPSV-5100\u003c\/strong\u003e\u003cbr\u003e12 kg \/ 26 lb 7.3 oz\u003cbr\u003e59 × 45 × 32 cm \/ 23 2\/8\" × 17 6\/8\" × 12 5\/8\"\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPSUV-5100\u003c\/strong\u003e\u003cbr\u003e13 kg \/ 28 lb 10.6 oz\u003cbr\u003e59 × 45 × 32 cm \/ 23 2\/8\" × 17 6\/8\" × 12 5\/8\"\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpectrophotometer\u003c\/li\u003e\n\u003cli\u003eFactory calibration report\u003c\/li\u003e\n\u003cli\u003e1 cm glass cuvettes (4)\u003c\/li\u003e\n\u003cli\u003e1 cm quartz cuvettes (2)\u003c\/li\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUser’s manual\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel Comparison\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSPSV-5100\u003c\/th\u003e\n\u003cth\u003eSPSUV-5100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Range\u003c\/td\u003e\n\u003ctd\u003e325–1000 nm (Visible)\u003c\/td\u003e\n\u003ctd\u003e190–1000 nm (UV-Visible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eTungsten Lamp\u003c\/td\u003e\n\u003ctd\u003eTungsten + Deuterium Lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD Display\u003c\/td\u003e\n\u003ctd\u003e2.5\" HD LCD\u003c\/td\u003e\n\u003ctd\u003e2.5\" HD LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd\u003eAutomatic (via arrow keys)\u003c\/td\u003e\n\u003ctd\u003eAutomatic (via arrow keys)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output\u003c\/td\u003e\n\u003ctd\u003eUSB, Parallel Port\u003c\/td\u003e\n\u003ctd\u003eUSB, Parallel Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003ePC Software (optional)\u003c\/td\u003e\n\u003ctd\u003ePC Software (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter Support\u003c\/td\u003e\n\u003ctd\u003eMicro thermal printer (optional)\u003c\/td\u003e\n\u003ctd\u003eMicro thermal printer (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Capacity\u003c\/td\u003e\n\u003ctd\u003e200 result sets\u003c\/td\u003e\n\u003ctd\u003e200 result sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eGeneral laboratory analysis\u003c\/td\u003e\n\u003ctd\u003eUV-visible sample analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese spectrophotometers are widely used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEducational and academic laboratories\u003c\/li\u003e\n\u003cli\u003eEnvironmental and water quality testing\u003c\/li\u003e\n\u003cli\u003eFood, beverage and agriculture testing\u003c\/li\u003e\n\u003cli\u003eIndustrial quality control\u003c\/li\u003e\n\u003cli\u003eChemical and pharmaceutical analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSPSV-5100\u003c\/th\u003e\n\u003cth\u003eSPSUV-5100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSingle beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e325–1000 nm\u003c\/td\u003e\n\u003ctd\u003e190–1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAutomatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤0.2%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0.3–3 A, 0–200%T, 0–9999 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Mode\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eT, A, C, F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e≤0.1%T at 360 nm\u003c\/td\u003e\n\u003ctd\u003e≤0.1%T at 220 nm \u0026amp; 360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤0.002 A\/30 min at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e128 × 64 Dots LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eW Lamp\u003c\/td\u003e\n\u003ctd\u003eW Lamp \u0026amp; D\u003csub\u003e2\u003c\/sub\u003e Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSB Port \u0026amp; Parallel Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC 85–250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPS-V_UV-5100-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPS-V_UV-5100-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSPSV-5100 Product Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSV-5100_Users_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSV-5100_Users_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSPSV-5100 Users Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSUV-5100_Users_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSUV-5100_Users_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSPSUV-5100 Users Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"SPSV-5100 - Visible Light","offer_id":47230408392928,"sku":"SPSV-5100","price":1883.5,"currency_code":"USD","in_stock":true},{"title":"SPSUV-5100 - Visible + UV Light","offer_id":47230408425696,"sku":"SPSUV-5100","price":2390.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/spsv-5100spsuv-5100-visible-light-spectrophotometer-spsv-5100-304558.jpg?v=1792535901"},{"product_id":"fermentation-ph-sensor-s8","title":"Fermentation PH Sensor - S8","description":"\u003ch1\u003eHigh Temperature pH Fermentation Sensor is designed for fermentation, pharmaceutical production and online monitoring of food and beverage processes.\u003c\/h1\u003e\n\u003cp\u003eA heat-resistant gel electrolyte and solid electrolyte double liquid junction support demanding process conditions and sterilization at 130°C.\u003c\/p\u003e\n\u003cp\u003eThe electrode requires no electrolyte refilling and minimal maintenance. An S8 connector and PG13.5 mounting thread support installation in compatible electrode assemblies, while optional lengths of 120, 150, 225 and 325 mm accommodate different process requirements. It is designed for use with a 316L stainless steel sheath and withstands pressure up to 0.4 MPa without back-pressure connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeat-resistant gel and solid electrolyte double liquid junction\u003c\/li\u003e\n\u003cli\u003eSuitable for sterilization at 130°C\u003c\/li\u003e\n\u003cli\u003eNo electrolyte refilling required\u003c\/li\u003e\n\u003cli\u003eS8 connector and PG13.5 mounting thread\u003c\/li\u003e\n\u003cli\u003eAvailable in 120, 150, 225 and 325 mm lengths\u003c\/li\u003e\n\u003cli\u003eDesigned for use with a 316L stainless steel sheath\u003c\/li\u003e\n\u003cli\u003ePressure resistance up to 0.4 MPa without back-pressure connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for biotechnology processes involving amino acids, blood products, insulin and interferon, as well as pharmaceutical production of antibiotics, vitamins and citric acid.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBrewing applications include mashing, boiling, fermentation, bottling, cold wort and deoxygenated water.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood and beverage uses include online monitoring of MSG, soy sauce, dairy products, juice, yeast, sugar and drinking water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0–130°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd\u003e6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003ePG13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eS8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Select One \u003e","offer_id":67897414418656,"sku":null,"price":348.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 120mm length","offer_id":67897414451424,"sku":null,"price":348.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 150mm length","offer_id":67897414484192,"sku":null,"price":387.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 225mm length","offer_id":67897414516960,"sku":null,"price":398.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 325mm length","offer_id":67897414549728,"sku":null,"price":473.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/fermentation-ph-sensor-s8-5347430.jpg?v=1791990913"},{"product_id":"sanitary-tri-clamp-conductivity-sensor","title":"Sanitary Tri-Clamp Conductivity Sensor","description":"\u003ch1\u003eThe Tri-Clamp Conductivity Sensor Series measures water conductivity across five configurations, with cell constants and probe lengths suited to different measurement ranges and installation requirements.\u003c\/h1\u003e\n\u003cp\u003eApplications include purified water systems, reverse osmosis, pharmaceutical processing, food production and industrial water monitoring.\u003c\/p\u003e\n\u003cp\u003eSelect K = 0.01 cm⁻¹ for measurements from 0 to 20 µS\/cm, K = 0.1 cm⁻¹ for 0 to 200 µS\/cm or K = 1.0 cm⁻¹ for 0 to 2,000 µS\/cm. Short and long versions are available for the K = 0.01 and K = 0.1 configurations, while the K = 1.0 configuration is offered in a short version.\u003c\/p\u003e\n\u003cp\u003eEach sensor features a stainless steel housing, a 50.5 mm Tri-Clamp flange and IP68 protection. All configurations have a specified temperature range of 0 to 120°C and pressure range of 0 to 4 bar. An NTC10K temperature sensor and 5 m signal cable are standard, with alternative temperature sensors and custom cable lengths available.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree cell constants covering conductivity ranges up to 2,000 µS\/cm\u003c\/li\u003e\n\u003cli\u003eFive configurations with different probe lengths\u003c\/li\u003e\n\u003cli\u003eMeasurement accuracy of ±2% of full scale\u003c\/li\u003e\n\u003cli\u003eStainless steel housing with 50.5 mm Tri-Clamp flange\u003c\/li\u003e\n\u003cli\u003eNTC10K temperature sensor as standard\u003c\/li\u003e\n\u003cli\u003eOptional PT1000, PT100 or NTC2.252K temperature sensors\u003c\/li\u003e\n\u003cli\u003e5 m standard signal cable with customizable lengths\u003c\/li\u003e\n\u003cli\u003eIP68 protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProbe Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eK = 0.01 cm⁻¹: Short or long probe configuration\u003c\/li\u003e\n\u003cli\u003eK = 0.1 cm⁻¹: Short or long probe configuration\u003c\/li\u003e\n\u003cli\u003eK = 1.0 cm⁻¹: Short probe configuration\u003c\/li\u003e\n\u003cli\u003ePT1000, PT100 or NTC2.252K temperature sensor in place of the standard NTC10K\u003c\/li\u003e\n\u003cli\u003eCustom signal cable lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eCell Constant\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity Range\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eOverall Length\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eProbe Length\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.01 Short\u003c\/td\u003e\n\u003ctd\u003e0.01 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–20 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.01 Long\u003c\/td\u003e\n\u003ctd\u003e0.01 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–20 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e125 mm\u003c\/td\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.1 Short\u003c\/td\u003e\n\u003ctd\u003e0.1 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–200 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e86 mm\u003c\/td\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.1 Long\u003c\/td\u003e\n\u003ctd\u003e0.1 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–200 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e126 mm\u003c\/td\u003e\n\u003ctd\u003e96 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 1.0 Short\u003c\/td\u003e\n\u003ctd\u003e1.0 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–2,000 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e89 mm\u003c\/td\u003e\n\u003ctd\u003e54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eShared Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eMeasurement Accuracy\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e±2% FS (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e0–120°C (32–248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003ePressure Range\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e0–4 bar (approximately 0–58 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 39.1875px;\"\u003eStandard Temperature Sensor\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 39.1875px;\"\u003eNTC10K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 39.1875px;\"\u003eOptional Temperature Sensors\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 39.1875px;\"\u003ePT1000, PT100 or NTC2.252K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eHousing Material\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eSignal Cable\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e5 m (16.4 ft.) standard; custom lengths available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eInstallation Type\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003eImmersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px;\"\u003eClamp\/Flange Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e50.5 mm (1.99 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eUpper Body Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e17 mm (0.67 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eProbe Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e14 mm (0.55 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eFlange Section Length\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 39.1875px; text-align: left;\"\u003eUpper Section Length\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 39.1875px;\"\u003e20 mm for K = 0.01 Short, K = 0.01 Long and K = 0.1 Long; 25 mm for K = 0.1 Short and K = 1.0 Short\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003ch3\u003eWhich cell constant should I choose?\u003c\/h3\u003e\n\u003cp\u003eSelect a configuration that covers your expected conductivity range: K = 0.01 cm⁻¹ for 0–20 µS\/cm, K = 0.1 cm⁻¹ for 0–200 µS\/cm or K = 1.0 cm⁻¹ for 0–2,000 µS\/cm.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the short and long versions?\u003c\/h3\u003e\n\u003cp\u003eThe versions have different overall and probe lengths to accommodate installation requirements. The measurement range remains the same for versions with the same cell constant.\u003c\/p\u003e\n\u003ch3\u003eWhich temperature sensor is included?\u003c\/h3\u003e\n\u003cp\u003eNTC10K is standard. PT1000, PT100 and NTC2.252K are available as options. Confirm compatibility with the connected instrument before ordering.\u003c\/p\u003e\n\u003ch3\u003eCan the cable length be customized?\u003c\/h3\u003e\n\u003cp\u003eYes. The standard signal cable is 5 m long, with custom lengths available.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Select \u003e","offer_id":67950394114272,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.01 - Short Type","offer_id":67950394147040,"sku":"SSHEC100-0.01-S","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.01 - Long Type","offer_id":67950394179808,"sku":"SSHEC100-0.01-L","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.1 - Short Type","offer_id":67950394212576,"sku":"SSHEC100-0.1-S","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.1 - Long Type","offer_id":67950394245344,"sku":"SSHEC100-0.1-S","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=1.0 - Short Type","offer_id":67950394278112,"sku":"SSHEC100-1.0-L","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/sanitary-tri-clamp-conductivity-sensor-3534364.jpg?v=1792184831"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/collection-pharmaceuticals.jpg?v=1793166913","url":"https:\/\/sperdirect.com\/collections\/pharmaceuticals.oembed","provider":"Sper Scientific Direct","version":"1.0","type":"link"}